TECHNICAL
MANUAL
Multi-apartment Gateway 1456B
40-56 Vdc
B+-
A1
SOLO CON CAVO ROSSO COMELIT 2E7T000500
ONLY WITH COMELIT RED CABLE 2E7T000500
FIXED POE SETTABLE POE N0 POE
A2 A3 A4
Art 1456B

2
Intended use
This Comelit product has been designed and manufactured for use in the creation of audio and video communication
systems in residential, commercial, industrial and public buildings.
Installation
All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with
careful observation of the indications provided in the Manuals / Instruction sheets supplied with those products.
Wires
Disconnect the power supply before carrying out any operations on the wiring.
Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system
manual.
We advise against running the system wires through the same duct as power cables (230V or higher).
Safe usage
To ensure Comelit products are used safely:
• carefully observe the indications provided in the Manuals / Instruction sheets
• make sure the system created using Comelit products has not been tampered with / damaged.
Maintenance
Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance
with the indications provided in the Manuals / Instruction sheets.
Any repairs must be carried out:
• for the products themselves, exclusively by Comelit Group S.p.A.,
• for the systems, by qualified technical personnel.
Disclaimer
Comelit Group S.p.A. accepts no liability for
• any purpose other than the intended use
• failure to observe the indications and warnings contained in this Manual / Instruction sheet.
Comelit Group S.p.A. reserves the right to change the information provided in this Manual / Instruction sheet at any
time and without prior notice
Warning
Table of contents
Warning ............................................................................................ 2
Description....................................................................................... 3
Settable POE.............................................................................................4
Technical characteristics................................................................ 5
Configuration of Art.1456B ............................................................ 6
1) Connection ...........................................................................................6
ViP NETWORK + INTERNET CONNECTION NETWORK ...................6
SYSTEM WITH SINGLE NETWORK ...................................................7
2) ViP Manager addressing .....................................................................8
CASE 1: default address of the device (192.168.1.200) belonging to
the same router network (e.g.: 192.168.1.1).......................................8
CASE 2: default address of the device (192.168.1.200) NOT belonging
to the same router network (e.g.: 192.168.0.1).................................10
3) Licence activation..............................................................................13
LICENSES AVAILABLE FOR PURCHASE.........................................14
4) DynDNS configuration for remote connection................................15
5) Port Forwarding setting for remote connection..............................16
6) SIP settings.........................................................................................17
7) SIP phone lines configuration...........................................................18
8) Apartments configuration .................................................................19
9) Users configuration (devices) ...........................................................20
10) App Directories Configuration ........................................................21
Directory creation..............................................................................21
Directory development......................................................................21
11) Message server configuration ........................................................23
12) Enabling Remote configuration ......................................................24
Special configurations .................................................................. 25
App connection settings........................................................................25
Connection to the configuration web pages .............................. 26
1A) Remote connection .........................................................................26
1B) Local connection .............................................................................26
2) Login....................................................................................................26
Backup and restore....................................................................... 27
Reboot with predetermined network settings............................ 28
Restoring factory settings ............................................................ 28
Restoring licenses......................................................................... 29
Wiring diagrams............................................................................. 30
system with ViP network + Internet connection network ..................30
System with single network ..................................................................31
Glossary* ........................................................................................ 32

3
4
5
6
7
8
9
1 2 3
Art.1456B
A1
SOLO CON CAVO ROSSO COMELIT 2E7T000500
ONLY WITH COMELIT RED CABLE 2E7T000500
FIXED POE SETTABLE POE N0 POE
A2 A3 A4
Description
Article 1456B is a multi-apartment gateway that:
• can serve up to 200 apartments, with a maximum of 15 slave devices per apartment;
• answer calls from a external unit via a virtual door entry monitor App for smart phone/tablet or using a normal GSM or
landline telephone;
• incorporates the SIP protocol to enable telephone calls via SIP server or via virtual lines purchased from a SIP services
provider;
• allows up to 4 simultaneous audio/video calls;
• can be configured remotely from a web interface.
1. B Ethernet port (“POE”) for ViP system riser input (default addressing: “Autoip”).
2. Dip switches for the procedures ““Reboot with predetermined network settings” and “Restoring factory settings”.
3. Power supply input via Art. 1441, Art. 1441B.
4. CV1 and CV2 for setting port A2.
5. CV3and CV4 for setting port A3.
6. A4 non POE Ethernet port for PC or router connection (default: “Static IP address” 192.168.1.200, netmask
255.255.255.0).
7. A3 non POE settable Ethernet port “POE” (default: “Static IP address” 192.168.1.200, netmask 255.255.255.0). Set
the port as “POE” (see “Settable POE”) if you want to connect devices that require a power supply (door entry
monitors, for example).
8. A2 non POE settable Ethernet port “POE” (default: “Static IP address” 192.168.1.200, netmask 255.255.255.0). Set the
port as “POE” (see “Settable POE”)if you want to connect devices that require a power supply (door entry monitors,
for example).
9. A1 Ethernet port “POE” (default: “Static IP address” 192.168.1.200, netmask 255.255.255.0).
With port “POE” DO NOT use standard Ethernet to connect to the router or to the PC; use only the red
Comelit cable Art.2E7T000500 to connect to the router or to the PC.

4
1441
1441B
PoE
NON PoE NON PoE
PoE
Max 1 PoE
40-56 Vdc
B+-
A1
SOLO CON CAVO ROSSO COMELIT 2E7T000500
ONLY WITH COMELIT RED CABLE 2E7T000500
FIXED POE SETTABLE POE N0 POE
A2 A3 A4
40-56 Vdc
B+-
A1
SOLO CON CAVO ROSSO COMELIT 2E7T000500
ONLY WITH COMELIT RED CABLE 2E7T000500
FIXED POE SETTABLE POE N0 POE
A2 A3 A4
1440
CV1
CV2
CV3
CV4
With the device powered by Art. 1440 via port B, there will be sufficient PoE power available to operate a
maximum of 1 door as “POE” on port A1, A2 or A3.
Settable POE
SETTABLE POE
A2 A3
DEFAULT
CV1 CV2 CV3 CV4
CV1 CV2 CV3 CV4
NON POE
STANDARD ETHERNET
CV1 CV2 CV3 CV4
CV1 CV2 CV3 CV4
NON POE
STANDARD ETHERNET
SETTABLE
CV1 CV2 CV3 CV4
CV1 CV2 CV3 CV4
POE
DO NOT USE STANDARD ETHERNET
Only connect to the router or
PC using the red Comelit cable
2E7T000500
CV1 CV2 CV3 CV4
CV1 CV2 CV3 CV4
POE
DO NOT USE STANDARD ETHERNET
Only connect to the router or
PC using the red Comelit cable
2E7T000500

5
Technical characteristics
MAIN FEATURES
Compatible system SYSTEM
DIN rail mounted Yes
DIN modules (no.) 4
Power supply voltage 48Vdc - 56Vdc
Min/max power consumption (mA) 50mA
Operating temperature (°C) +5°C to +40°C
Operating relative humidity 25% / 75%
IP protection rating IP30
GENERAL DATA
Product height (mm) 62
Product width (mm) 70
Product depth (mm) 90

6
40-56 Vdc
B+-
A1
ONLY WITH COMELIT RED CABLE 2E7T000500
ONLY WITH COMELIT RED CABLE 2E7T000500
FIXED POE SETTABLE POE NON POE
A2 A3 A4
Art 1456B
t.
INTERFACE B
IP ADDRESS AUTOIP
INTERFACE A
STATIC IP ADDRESS
192.168.1.200 (default)
ROUTER
Installer PC
ViP SYSTEM
with ViP Manager
version 2.5.0 and higher
with active
internet connection
INTERNE T
SIP
PROVIDER
1) Connection
Configuration of Art.1456B
√This operation requires a PC loaded with the software ViP Manager version 2.5.0 or later (downloadable from the website
pro.comelitgroup.com).
√An active internet connection is also required.
fArticle1456B has 2 network interfaces, A and B, labelled for easy identification, which can be configured separately to meet
dierent system requirements. Depending on the type of system, connect the devices as shown in the following figures:
Take particular care with regard to the network interface settings and do not configure interfaces A and B
with the same addresses or similar parameters: each IP address must be unequivocal, the addresses of the
interfaces A and B must not belong to the same subnet.
ViP NETWORK + INTERNET CONNECTION NETWORK

7
INTERFACE A
STATIC IP ADDRESS
192.168.1.200 (default)
40-56 Vdc
B+-
A1
ONLY WITH COMELIT RED CABLE 2E7T000500
ONLY WITH COMELIT RED CABLE 2E7T000500
FIXED POE SETTABLE POE NON POE
A2 A3 A4
Art 1456B
t.
ROUTER
Art.1441
Art.1441B
ViP SYSTEM
Installer PC
with ViP Manager
version 2.5.0 and higher
with active
internet connection
INTERNE T
SIP
PROVIDER
All system devices form part of a single network, so it it is only necessary to configure interface A.
In this case, DO NOT the alter the configuration of interface B.
SYSTEM WITH SINGLE NETWORK

8
INTERFACE A
STATIC IP ADDRESS
192.168.1.200 (default)
192.168.1.X
192.168.1.1
A1
ONLY WITH COMELIT RED CABLE 2E7T000500
ONLY WITH COMELIT RED CABLE 2E7T000500
FIXED POE SETTABLE POE NON POE
A2 A3 A4
Art.1456B
t.
ROUTER
...
Installer PC
...
a
b
c
d
Installer PC
SYSTEM
SCAN
IN DHCP
AN IP COMPATIBLE
WITH THE SYSTEM
WILL BE ASSIGNED
TO THE PC
E.G. 192.168.1.30
During the system scan...
CASE 1: default address of the device (192.168.1.200) belonging to the same router network (e.g.: 192.168.1.1)
2) ViP Manager addressing
Follow the procedure below to perform a system scan in “DHCP”, to locate all the devices connected to interfaces A and B:
• an IP address will be automatically assigned to the devices in addressing mode “Autoip” (connected to interface B);
• an IP address will be automatically assigned to the devices in addressing mode “DHCP” (connected to interface A), if
the system is connected to a server with the function “DHCP” active;
• devices with “Static IP address” will be identified only if they have a network address that is compatible with that of
interface A.
1. From Options [a] / Local connections [b] tick DHCP Enable [c] and confirm [d].
PERFORM A DHCP SYSTEM SCAN AND ASSIGN A ViP ADDRESS

9
f
h
i
g
e
2. Launch the system scan by pressing Scan System [e].
» all the devices connected to the system will be displayed in the device list.
3. Select the device 1456 B [f], select Addressing/ViP address [g], assign an unequivocal ViP address to the device [h] and
press Write page [i] to save the current settings.
In the case of a system with 2 1456B devices, it will be necessary to assign to interface A of one of the two
devices a new “Static IP address” (as described in "case 2"), as each device must have a unequivocal IP
address.

10
INTERFACE A
STATIC IP ADDRESS
192.168.1.200 (default)
192.168.0.X
A1
ONLY WITH COMELIT RED CABLE 2E7T000500
ONLY WITH COMELIT RED CABLE 2E7T000500
FIXED POE SETTABLE POE NON POE
A2 A3 A4
Art.1456B
t.
ROUTER
... ...
Installer PC
192.168.0.1
b
c
d
Assign to the PC an
IP address that is
compatible with the
network of the 1456B
(e.g.: 192.168.1.2) so that
the two devices are able
to communicate
a
Interface A must be assigned a new “Static IP address” in the same network as the devices connected to
interface A
CASE 2: default address of the device (192.168.1.200) NOT belonging to the same router network (e.g.: 192.168.0.1)
ASSIGN A NEW STATIC IP ADDRESS TO INTERFACE A
The following procedure describes how to assign network settings to the device1456B that are compatible with those of the
devices connected to interface A.
1. Open the software ViP Manager version 2.5.0 or later (downloadable from the website pro.comelitgroup.com).
2. From Options [a] / Local connections [b] untick the DHCP enable box and assign an IP address to your PC [c] (in the
example: 192.168.1.2)* that belongs to the same network as the IP address of interface A (default=192.168.1.200)and
confirm [d].
*the last value must be within the range of 2 to 253 excluding: 200 (assigned to the gateway Art. 1456B) and the values
already assigned to other devices connected to the network.
Table des matières
Autres manuels Comelit Porte
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur