CIAT CIATControl OPC Server Manuel utilisateur

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [1]
V05.2012
CIATControl OPC Server
OptimumcontrolforHysyssystemsolutionsforoffices,
hotelsandseniorcitizenresidences
Installationandoperating
instructions
Description:
•StandardOPCcommunicationsolution
•Centralisationofthesystem'svariousCIATControlsonanOPC‐compatibleBMS
•Largerangeoflicencesformonitoring:
o1CIATControl
o2to5CIATControls
oOver5CIATControls
•Quick,intuitiveinstallation
Includes:
•InstallationCD
•Dongle(licence)
•Installationandoperatinginstructions
Tobecarriedoutbytheintegrator:
•InstallationoftheOPCserverontheBMS
•CIATControlIPconfiguration
•CIATControldeclarationviatheOPCserverconfigurator
•SelectionofpointstobeindicatedontheBMS

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [2]
V05.2012
1. LISTOFEQUIPMENT
No.DescriptionQuantityComment
1InstallationCD1Minimumrequirements:
WindowsXP/7/Server2008compatible
Processor:1.6Ghz
RAM:1Gb
Diskspace:1Gb
CDplayer
1USBportavailable
.NetFrameworkversion2.0
2Dongle(licence)1TobeconnectedtotheUSBport
3Installationandoperatinginstructions1‐
2. INSTALLINGTHESOFTWARE
InserttheinstallationCDintheCDplayer.
Doubleclickontheicontolaunchtheinstallation.Thefollowingwindowappears.

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [3]
V05.2012
Followtheinstallationinstructionsandclickon"Finish"afterselecting"Yes,Iwanttorestartmycomputernow".
Note:makesureyoucloseallyouropendocumentsbeforeclickingon"Finish".
Afterrestartingyourcomputer,theOPCserverwillbeoperational.
Connectthedongletoactivatethelicence.
3. CONFIGURINGTHESTATIONS
1/ConfiguringtheCIATControls
ConfigureeachCIATControlwithafixedIPaddress.
Todothis,identifyyourselfasa"User",clickon"Parameters"andselectthe"Ethernetconfiguration"tab.

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [4]
V05.2012
ConnectanRJ45cabletooneofthe2EthernetportsontheCIATControl.
Note:eachCIATControlhasadefaultDHCPsetting.
OnceanaddresshasbeenassignedtotheCIATControl,theactiveboardisdisplayed.
Select"Static"andentertheinformationsuppliedbythenetworkadministrator(orthatassignedbytheDHCPserver):
‐IPaddress
‐Subnetmask
‐Gateway
Clickon"Send"toconfirmtheconfiguration.
Note:ifseveralCIATControlsarepresentonthenetwork,pleasemodifythecomputername(defaultname:
CIATCONTROL)toauniquenametoavoidconflicts.TheCIATControlwillneedtoberestartedafterthenamehasbeen
modified.
CarryoutthesameoperationoneachCIATControl,takingcaretoassigndifferentfixedIPaddressesforeach
CIATControl.

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [5]
V05.2012
2/ConfiguringtheOPCserver
In"Start","Programs",clickon"OPCServerConfigurator".
Thefollowingwindowopens.
Clickon"NEW"toaddaCIATcontrol.

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [6]
V05.2012
EnteranameforthisequipmentanditsfixedIPaddress,thenclickon"OK".
Clickon"PING"tocheckthecommunicationwiththeequipment.
Itsstatusswitchesto"Success".
RepeattheoperationforeachCIATControl.
WhenalltheCIATControlshavebeenconfigured,closetheapplicationbyclickingonthecrossinthetopright.
TheOPCserverisnowconfigured.

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [7]
V05.2012
AnyOPCclientcanconnecttheOPCservertoaccessthevaluesforalltheCIATControlsavailableonthesystemand
declaredontheserver.
Notes:
OtheractionsarepossiblefromtheOPCserverconfigurator:
‐"MODIFY":usedtomodifythenameorIPaddressoftheequipment
‐"DELETE":usedtodeletetheequipment
‐"REFRESH":usedtostartapingforalltheequipmentonthelist
‐"SETTINGS":usedtoconfiguretheOPCserverparameters
The"SETTINGS"menuisusedtomodifythefollowingparameters:
‐Booleanvalueistrue:appliestoallOPCitemscreatedwiththebooltype;iftheboxischecked,thevalue
codedfortrueis1;iftheboxisnotchecked,itis‐1.
‐Reconnectevery:frequencyofreconnectiontoastationdeclaredabsentonthenetwork.Whenastationis
declaredabsentafteralossofcommunication,theOPCserverusesthisfrequencytocheckthatthestation
hasreturnedtothenetwork
‐Refreshtime:waitingtimeactivatedwitheacheventpriortostationupdate.Thisisused,forexample,when
addingitemstothestationformonitoring:itisusedtosendthelistofitemstobemonitoredonceallthe
itemshavebeendeclared,ratherthanupdatingthestationeachtimeanitemisadded/deleted.Inparticular,
thissavestimewheninitialisingtheOPCserver
‐Disconnectiontime:waitingtimepriortodisconnectionofthelinkbetweentheOPCserverandthestationfor
whichnoitemsarereadbytheOPCserver
‐Dataservertestfrequency:cyclicaltesttocheckforthepresenceofthestation(useofthepingcommand)
‐TCPtimeout:configurationofthetimeoutperiodontheTCPcontrolwhencheckingforthepresenceofthe
stationonthenetwork
‐Nativetypeisstring:appliestoOPCitemsforwhichthetypeisdefinedasstringiftheboxischecked.
Otherwisethetypeisundefined
‐Addressseparator:characterusedtoseparatethedifferentfieldsoftheOPCaddress(devicefield,network
field,variablefield,etc.)
4. USE
TheOPCserverlaunchesautomaticallywhenanOPCclientattemptstocommunicatewiththeCIAT.CIATControlOPC
Server.DAserver.
AnyOPCclientcannowselecttheitemshewishestomonitor(seesections7to10fortheitemsavailableforeachtype
ofequipment).
TheOPCserverhasthefollowingbuttons:
‐Stations…:usedtocheckthestationsinterrogatedbytheOPCclient;itispossibletorefreshtheconnections
orattempttoreconnectifthereisalossofcommunicationwithoneofthestations.

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [8]
V05.2012
‐Exit:usedtoclosetheOPCserver.Ifequipmentisaddedtotheserver,itisrecommendedtoshutdownthe
serverbeforeconfiguring,otherwiseanymodificationswillonlybetakenintoaccountoncetheOPCserveris
restarted.
‐Group:usedtoindicatetheitemsreadbytheOPCclient.Thefulladdressisindicated,aswellastherefresh
timeandvalue.
‐Badaddresses:usedtoindicateincorrectaddressesread/writtenbytheOPCclient.Iftheseaddressesdonot
exist,theywillbedirectlyplacedinthismenu.
‐Groupdetails:givesageneraloverviewoftheOPCserveraswellasthevalueoftheparameterssetintheOPC
serverconfigurator.
‐Filter:usedtoapplyafiltertotheitemslistedinthetable.Simplyenterthecharacterspresentintheaddress
ofeachitem.Thefilterrefreshesautomatically.

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [9]
V05.2012
ImportantnotesfortheinstallationprocedureviaOPC:
‐Thevalueswrittenintheequipmentparametersarenotstoredinthedatabase.Whenreplacingthe
modules(inoperativemodule),theparametervaluesshouldbechangedagain.Onlythevaluessetviathe
CIATControlscreenarestoredinthedatabase.
‐TakecarewhenwritingtheparametervaluesforV3000typemodules.Whenaparameterismodified,the
V3000restartsautomatically.Itthenlosesthecontextinwhichitwasswitchedto"Auto"mode.Itwillnot
switchbacktothemoderequestedbythetimeschedulewhenthemodenextswitches.Topreventthis,the
OPCclientmustsendthecommandtotheV3000inordertomakeitswitchbacktothemodeitwasin
beforetherestart.
‐TheitemsavailableforeachpieceofequipmentaredisplayedinFrenchonly.
5. UNINSTALLING
Touninstallthesoftware,theOPCservermustbeshutdown,whichrequiresalltheOPCclientstobeclosed.
Doubleclickonthe"CIAT"iconinthebottomrightofthetaskbar.
Thefollowingwindowopens.Clickon"Exit"andconfirmthattheapplicationhasclosed.

NA 12.46 A
©2012CIAT
NA 12.46 A installation instructions [10]
V05.2012
In"Configurationpanel",clickon"ProgramandFunctions"(Win7)or"Add/Removeprograms"(WinXP/Win
Server2003/2007).
Select"CIATControlOPCServer"andclickonuninstall.Thefollowingwindowopens.Followtheinstructions.
Table des matières
Autres manuels CIAT Unité de contrôle

CIAT
CIAT V3000 KNX Manuel d'utilisation et d'entretien

CIAT
CIAT AeroCONNECT 1B Manuel d'utilisation et d'entretien

CIAT
CIAT CS1B Manuel utilisateur

CIAT
CIAT microciat MRS2.2A Mode d’emploi

CIAT
CIAT MAGISTER Series Manuel utilisateur

CIAT
CIAT XtraConnect 2 Mode d’emploi

CIAT
CIAT Magister 2 Series Mode d’emploi

CIAT
CIAT Vectic Manuel utilisateur
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur