Page 8 SP Manual
Conguration Settings
Step 1CS – Press NEXT and simultaneously for 5 seconds and release. Press NEXT and
simultaneouslyfor5secondsandrelease.IfthescreeninStep2CSdoesnotappear,thelockonthevalveis
activated.Tounlock,press,NEXT,andREGENinsequence,thenpressNEXTandsimultaneously
for 5 seconds and release. Press NEXT and simultaneously for 5 seconds and release.
Step 1CS
Step 2CS – Use or to select 1.0 for 1” valve, 1.25 for 1.25” valve, 1.5 for 1.5” valve, 2.0 for 2” valve
or 1.0T for twin valve. Press NEXT to go to Step 3CS. Press REGEN to exit Configuration Settings.
Step 2CS
Step3CS– If1.5 or 2.0isselected in Step2CS,an additionalscreenwill
appear. It is used to select which size flow meter is to be used with the
valve,1.0r,1.5, 2.0 or 3.0. Variable meterpulsesof0.1-150.0PPG can
alsobeselected.PressNEXTtogotoStep4CS.PressREGENtoreturn
to the previous step.
Step 3CS
Step 4CS Step 4CS – Selecting the use of an outside signal to initiate a regeneration: Selection only matters if a
connectionismadetothetwopinconnectorlabeledDPSWITCHlocatedontheprintedcircuitboard.
Following is an explanation of the options:
oFF - feature not used
NOTE:InatwinalternatingsystemeachcontrolmusthaveaseparatedPsignalordPswitch.OnedPsignal
or one dP switch cannot be used for both controls.
on0–IfthedPswitchisclosedforanaccumulativetimeof2minutesaregenerationwillbesignaledtothe
unit.InatwinalternatingsystemtheMAVwilltransitionfirsttoswitchunitssothatthesignaledunitcan
startregeneration.AftertheMAVhasfullytransitioned,theregenerationbeginsimmediately.Note:For
WS1–WS1.5controlvalvesprogrammedfortwinalternating:ifthedPfunction“on0”isset,theDelayed
Rinse and Fill feature is not available.
dEL – If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur at the
scheduled delayed regeneration time. In a twin alternating system once the dP switch is triggered the
PC Board will display “REGEN TODAY” and when the delayed regen time comes the control will
switchtanksandthetriggeredunitwillthengointoregeneration.Note:ForWS1–WS1.5controlvalves
programmedfortwinalternating:ifthedPfunction“dEL”isset,theDelayedRinseandFillfeatureisnot
available.
HoLd – If the dP switch is closed a regeneration will be prevented from occurring while there is switch
closure.Inatwin alternatingsystemtheregenerationofaunitcanbepreventeduponswitchclosure.Ifthe
unitdepletesthecapacitydowntozero,itwillnotbeallowedtoswitchtankstoregenerateuntiltheswitch
isopen.Note:ForWS1–WS1.5controlvalvesprogrammedfortwinalternatingtheDelayedRinseand
Fill feature can be set.
Press NEXT to go to Step 5CS. Press REGEN to return to previous step.