5
5
1. If do parallel operation with controlled devices in electric furnace of high capacity,
THYRISTOR for welding machine, there may be occasion of malfunction.
Separate and wire by separate power circuit.
2. When do wiring CW-COM, CCW-COM for switching the direction at wiring for
external remote control, please be careful not to be connected CW-COM,
CCW-COM terminals at the same time.
( when operate in state of connected CW-COM, CCW-COM both terminals,
there may be malfunction and can go hard on the motor. )
Wiring Precautions
1. Do not carry catching LEAD WIRE part of MOTOR. There is risk of disconnection.
2. Protect MOTOR SHAFT to protect against damage.
3. Do not hang down or get on MOTOR absolutely.
4. Take care water not to be bound in place with danger of water contact.
5.Do not operate with wet hands.
6. Turn off power certainly when do installing, moving, wiring and checking.
7. Do not touch absolutely on rotating part of MOTOR.
8. Do not use damaged MOTOR..
9. In case of discard this product, process as industrial waste.
10. If you need repairs, please contact us or purchased shop.
11. Do not remodel by the customer, because it is beyond the scope of the warranty
of our company.
Handling Precautions
1. Use surface temperature of MOTOR at below 90℃.
2. If do not use long period, please turn OFF power.
3. Set switch to 'STOP' position certainly before connect power.
4. Do not touch the hands or body while operating or just after stop.
There are worries of burn ecause MOTOR surface is high temperature.
5. If malfunction occurs, turn off the power immediately and stop.
6. When was power failure or THERMAL PROTECTOR was working, turn off power.
Due to an unexpected restart may cause injury.
Operating Precautions