Carrier Access Bridge/Router 3104s Manuel utilisateur

Adit 3104
QUICK START GUIDE
Part Number: 002-0219-0410
Product Release: 1.6
September 2007

Copyright 2007 Carrier Access Corporation. All rights reserved.
The information presented in this manual is subject to change without notice and does not represent a commitment on the
part of Carrier Access Corporation. The hardware and software described herein are furnished under a license or non-
disclosure agreement. The hardware, software, and manual may be used or copied only in accordance with the terms of this
agreement. It is against the law to reproduce, transmit, transcribe, store in a retrieval system, or translate into any medium
- electronic, mechanical, magnetic, optical, chemical, manual, or otherwise - any part of this manual or software supplied
with the Adit 3104 for any purpose other than the purchaser’s personal use without the express written permission of
Carrier Access Corporation.
The Carrier Access Logo and Adit are registered trademarks of Carrier Access Corporation. All other brand or product
names are trademarks or registration trademarks of their respective companies or organizations.
Contact Information:
Carrier Access Corporation
5395 Pearl Parkway
Boulder, CO 80301-2490
Corporate Phone: (303) 442-5455
Fax: (303) 443-5908
www.carrieraccess.com
Customer Support Direct: (800) 786-9929
E-mail: tech-suppor[email protected]

QUICK START GUIDE
Quick Start
In this Guide
Unpacking and Inspection
Installation Environment
User Safety
Installation
-Compliant Installation
-Ferrite Beads
-Wall Mounting
-Rack Mounting (Optional Feature)
-Adit 3104, 3200 and 3400 Battery Backup
Chassis Overview
Interface Connectors
Reset Button
Alarm/Status LEDs
Web-Based Management
Setting up a CLI Connection
Log in
Key Enabled Software Features
Basic Configuration
-Setup Adit for access via Web-Browser
-Restore Factory Defaults
-Modify Default Admin User
-Configure Ethernet WAN Interface
-Configure Serial1 as WAN
-Configure the Adit 3104 as a SIP Line Gateway

4Adit 3104 - Release 1.6
Quick Start
Unpacking and Inspection
Unpacking and Inspection
WARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES.
1. Inspect containers for damage during shipment. Report any damage to the freight carrier for
possible insurance claims.
2. Compare packing list with office records. Report any discrepancies to the office.
3. Open shipping containers, be careful not to damage contents.
4. Inspect contents and report any damage.
5. If equipment must be returned for any reason, carefully repack equipment in the original
shipping container with original packing materials if possible.
6. If equipment is to be installed later, replace equipment in original shipping container and store
in a safe place until ready to install.
Electrostatic Discharge (ESD) Precautions
ESD can damage processors, circuit cards, and other electronic components. Always
observe the following precautions before installing a system component.
1. Do not remove a component from its protective packaging until ready to
install it.
2. Wear a wrist grounding strap and attach it to a metal part of the system unit
before handling components. If a wrist strap is not available, maintain contact with the system
unit throughout any procedure requiring ESD protection.
WARNING! INTEGRATED CIRCUITS (ICS) ARE EXTREMELY SUSCEPTIBLE TO ELECTROSTATIC
DISCHARGE. UNLESS YOU ARE AQUALIFIED SERVICE TECHNICIAN WHO USES TOOLS AND
TECHNIQUES THAT CONFORM TO ACCEPTED INDUSTRY PRACTICES, DO NOT HANDLE ICS.
The ESD warning label appears on packages and storage bags that contain static-sensitive products and
components.
Installation Environment
The environment in which you are installing the Adit 3000 must meet the following conditions:
zOperating temperature range: 32° to 104° F (0°to 40°C)
zStorage temperature range: -40° to 158° F (-40°to 70°C)
zMaximum operating altitude: 10,000 ft. (3,048 m)
zMaximum non-operating altitude: 40,000 ft. (12,192 m)
zRelative humidity (non-condensing) range: 0 to 95%
WARNING! THE ADIT 3000 IS DESIGNED FOR WALL AND RACK MOUNTING ONLY. ITIS NOT
DESIGNED FOR DESKTOP USE.

Adit 3104 - Release 1.6 5
Quick Start
User Safety
User Safety
CAUTION! WHEN USING YOUR TELEPHONE EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD
ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSONS,
INCLUDING THE FOLLOWING:
zDo not use this product near water for example, near a bathtub, washbowl, kitchen sink or
laundry tub, in a wet basement or near a swimming pool.
zAvoid using a telephone (other than a cordless type) during an electrical storm. There may be
a remote risk of electric shock from lightning.
zDo not use the telephone to report a gas leak in the vicinity of the leak.
zUse only the power cord and batteries indicated in this manual. Do not dispose of batteries in a
fire. They may explode. Check with local codes for possible special disposal instructions.
zRefer to the installation section of this manual for a safe and proper installation procedure. All
wiring external to this equipment should follow the current provision of the National Electrical
Code.
Installation
The following are instructions for a compliant installation of the Adit 3104. Please note the following
warnings, before installing the unit.
For wall and rack mount instructions, use the links listed below to the appropriate section:
zInstallation
zWall Mounting
zRack Mounting (Optional Feature)
WARNING! OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES. SEE
Electrostatic Discharge (ESD) Precautions ON PAGE 4 FOR DETAILED INFORMATION.
WARNING! THE ADIT 3104 DS1 NETWORK INTERFACE PORTS ARE CERTIFIED WITH ACTA,
INDUSTRY CANADA AND UL FOR DIRECT CONNECTION TO PUBLIC DIGITAL NETWORKS. TOPREVENT
EQUIPMENT DAMAGE FROM LIGHTNING SURGES, AC INDUCTION OR POWER LINE CONTACT, UTILIZE
LISTED PRIMARY PROTECTORS AT THE BUILDING ENTRANCE WITH MINIMUM 4 OHM CURRENT-
LIMITING AND MAXIMUM 600V IMPULSE BREAKDOWN AT 1000V/USEC. THE ADIT 3104 DS1 PORTS
COME EQUIPPED WITH SECONDARY OVERVOLTAGE AND OVERCURRENT PROTECTION. THE
INSTALLATION IS REQUIRED TO MEET LOCAL OR NATIONAL ELECTRIC CODES FOR COMMUNICATION
SYSTEMS.
WARNING! THE ADIT 3104 FXS INTERFACE PORTS ARE INTENDED TO SERVE INDOOR
COMMUNICATION CONDUCTORS ONLY. OVERVOLTAGE AND OVERCURRENT PROTECTION IS
PROVIDED TO PREVENT EQUIPMENT DAMAGE FROM LIGHTNING SURGES OR AC POWER LINE
CONTACT INSIDE BUILDINGS. THE FXS PORTS ARE NOT SUITABLE FOR CONNECTION TO EXPOSED
OUTDOOR COMMUNICATION CONDUCTORS.

6Adit 3104 - Release 1.6
Quick Start
Installation
Compliant Installation
NOTE: It is important the DS1/E1 Network Interface Cables are secured separately from the
power and Signal Cables.
1. Inspect the unit.
2. Mount the unit, see Wall Mounting on page 7, or Rack Mounting (Optional Feature) on page 8
for detailed instructions.
3. Ground the unit. See Grounding the Unit on page 12.
WARNING! THE ADIT 3104 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE
PROTECTION OF USERS AND SERVICE PERSONNEL. REFER TO Grounding the Unit ON PAGE 12 FOR
DETAILED INSTRUCTIONS.
4. Connect DS1 (T1), Ethernet and Amphenol connectors as needed.
Note: if Amphenol (25-pin telco) connector is used, a ferrite bead is required to meet
compliance (see graphic above).
5. Connect RS-232 connector and open Terminal Emulator software on your PC. Note: With this
running first, you can monitor the boot process.
6. Connect Power to the unit.
7. Monitor the boot process on your PC, when complete the status light should be green.
8. For any software enabled features, enter the key command. See the key command in the Adit
3000 CLI Reference Manual,for detailed information.
9. To verify use the show version command.
10. Now you can proceed to provisioning the unit. See Basic Configuration on page 23 for
information.
Ferrite Beads
To be compliant with EMI standards, a ferrite bead is required on the following cable:
Ferrite bead shipped with Adit chassis:
Ferrite Provided Part Number Intended For
1 large P/N 010-0051 25-pair Telco cable (connector on the front of the Adit).

Adit 3104 - Release 1.6 7
Quick Start
Installation
Wall Mounting
Before beginning the mounting process, verify that the installation area is a stable environment, clean
and free from extremes of temperature, shock, vibration and EMI. See Installation Environment on
page 4.
The Adit 3000 is delivered with mounting brackets that can easily be attached for quick and easy wall
mounting, as shown in the illustration above.
To install the unit to the wall:
1. Attach the wall mount brackets to the Adit 3000, with wall attachment flange pointing away
from the unit, as shown above. Attach with 4 screws provided (2 for each bracket).
2. Mount the unit to the wall using appropriate mounting screws (not included). Note: it is
acceptable to mount on drywall with suitable anchor-type mounting screws.
NOTE: The Adit 3000 must be mounted with the brackets on the top and bottom, as shown
above.
Mounting Bracket
Leave adequate space
at the front/back for
access to connectors
Back of unit
Front of unit

8Adit 3104 - Release 1.6
Quick Start
Installation
Rack Mounting (Optional Feature)
NOTE: Rack mounting kits are available for both 19 and 23 inch racks. 1 Rack Unit (RU) of spacing
is required above the Adit 3000 in the Rack Mount Unit.
To rack mount the Adit 3000, follow the instructions below:
1. Attach bracket ears to Rack Mounting Tray using four #10-32 x 1/4" screws on each side. The
Mounting Ears can be used for both a 19 or 23 inch rack. The drawing below shows a top view
of the 2 versions.
2. Remove wall mount and screws from Adit 3000 unit.
23 in rack
19 in rack
Front
Front
screws
screws
screws
screws
Rack Mount Tray
Rack Mount Tray
Mounting Ear
Mounting Ear
Mounting Ear
Mounting Ear
Mounting Ear
Rack Mounting Tray

Adit 3104 - Release 1.6 9
Quick Start
Installation
3. Place the Adit 3000 on the Tray Slide and attach with the 4 screws removed in step 2.
4. Slide the assembled piece (Adit 3000 and Tray Slide) onto the installed Rack Mounting Tray.
5. Secure the Tray Slide to the Rack Mounting Tray with the attached screws on the Tray Slide.
NOTE: the mounting brackets are designed to not allow units to be mounted closer than
recommended.
Tray Slide
screws
screws

10 Adit 3104 - Release 1.6
Quick Start
Installation
Adit 3104, 3200 and 3400 Battery Backup
Note: This is an Optional Feature.
The Adit 3104, 3200 and 3400 Battery Backup (P/N 730-0132), is a wall-mount battery backup unit to
provide up to 8 hours battery backup.
Please see the Battery Backup User Manual for product information and installation instructions, which
is provided with unit.
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Carrier Access Porte
Manuels Porte populaires d'autres marques

LST
LST M500RFE-AS Manuel utilisateur

Kinnex
Kinnex Media Gateway Manuel utilisateur

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuel utilisateur

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuel utilisateur

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuel utilisateur

Telsey
Telsey CPVA 500 - SIP Manuel utilisateur