C-Data EPON SFU Manuel utilisateur

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
C-DATA Z_EPON SFU Products
1GE/1GE+CATV
User Manual
Version:V1.1

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
Contents
1 Note..........................................................................................................................................1
1.1 Installation Precautions.......................................................................................................1
1.2 Precautions for Use.............................................................................................................1
2 Introduce.................................................................................................................................. 3
2.1 Product Feature................................................................................................................... 3
2.2 Environmental Requirements............................................................................................. 4
2.3 Product Interface Definitions..............................................................................................5
2.4 Product LED Definitions.................................................................................................... 5
2.5 Device Connection..............................................................................................................5
2.6 Network Application...........................................................................................................6
3 ONU Local WEB login........................................................................................................... 6
3.1 ONU and PC physical Connection..................................................................................... 6
3.2 Computer Access ONU Local WEB...................................................................................7
4 ONU Registration Information Configuration........................................................................ 8
4.1 ONU Registration Status View........................................................................................... 8
4.2 ONU Optical Power Information View.............................................................................. 8
4.3 ONU Registration LOID Configuration.............................................................................9
5 Internet Basic Configuration................................................................................................. 10
5.1 Routing mode broadband Internet settings.......................................................................10
5.2 Broadband Internet Access In Bridge Mode.................................................................... 15
5.3 View Broadband WAN Status...........................................................................................15
5.4 Delete Internet WAN Connection.....................................................................................15
6 ONU LAN configuration.......................................................................................................16
6.1 LAN IP Address Configuration........................................................................................ 16
7 Multicast / IPTV Service Basic Settings............................................................................... 17
8 CATV Management............................................................................................................... 18
8.1 CATV Parameter Configuration....................................................................................... 18
8.2 CATV Information View...................................................................................................18
9 ONU Device Management.................................................................................................... 19
9.1 ONU Device Remote Access Settings..............................................................................19
9.2 Restore Default................................................................................................................. 20
9.3 Software Upgrade............................................................................................................. 20
9.4 Reboot Device...................................................................................................................21
Concluding Remarks......................................................................................................................22

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
1
1 Note
1.1 Installation Precautions
Do not near flammable or conductive items, high temperature, direct sunlight or moist
environment, or on PC chassis, and check whether other home equipment placed around
stability
Check the cable line. Test and confirm the ac or dc input voltage in the range of allowable,
and direct current (dc) correct polarity.
Unless the manufacturer has given permission, please use the volume and the types of the
power supply with Ming products attached adapter
To prevent lightning damage to the product, make sure that the power outlet and the power
adapter ground are securely grounded. In the thunderstorm, be sure to unplug the power and
all the connections.
Equipment shall be less than 10% of the input voltage fluctuations, power plug with a
refrigerator, hair dryer, electric iron not use the same socket.
To avoid any damage to body by power socket overload, or damage to cause electric shock or
fire plug, please check the power cord, if found damaged, please change immediately.
Please place the equipment on the smooth plane and equipment cannot be placed on other
items.
Equipment is easy heat when working, should maintain the appropriate cooling space to
avoid damage caused by overheating products. The elongated holes on the housing are
designed for heat dissipation. Keep the ventilation clean and prevent the items from falling
into the inside of the equipment. Doing so may cause damage or fire to the equipment. Do
not spill liquid onto the surface of the equipment.
1.2 Precautions for Use
Please read the user manual carefully before using the equipment and follow all the
precautions on the user manual.
Do not look straight at fiber which may damage the eyes. Please wear safety
glasses to effectively protect your eyes from damage. Wear the fiber cap when
fiber no in use.
Power off the device when it not in use.
Please make sure the power switch is closed before plug the power supply, to avoid
surge. Please be careful when remove the power supply, transformer temperature
may be higher.
For safety, please do not open the shell of equipment, especially equipment power
on.

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
2
Unplug the power supply before cleaning equipment. Use a soft dry cloth cleaning
equipment, do not use the liquid or spray.
Do not use this product connected to any electronic products unless got our engineer
allow. because any wrong connection may cause electricity or fire danger.

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
3
2 Introduce
ZTE EPON SFU series of terminal equipment is based on EPON technology based on
the broadband access market, to meet the broadcaster operators broadband access and
FTTH, and design passive optical network terminal products that integrate CATV optical
receiver and achieve broadband, CATV dual network integration. It is based on mature
and stable, cost-effective Gigabit EPON technology and integrate Gigabit Ethernet
switching technology, WDM technology and HFC light reception technology, with high
reliability, easy management and good quality of service (QoS) and so on. Technical
performance of equipment meet the IEEE802.3ah, China Telecom EPON equipment
technical requirements (V2.1 / V3.0) and other requirements.
EPON technology is a combination of PON technology and Ethernet technology
advantages of emerging technologies, is a point to multi-point networking technology,with
high bandwidth, high efficiency, large coverage, rich user interface and many other
advantages, is the operator to achieve access network business broadband, integrated
transformation of the ideal technology.
ZTE chipset EPON SFU series also integrates powerful routing and forwarding
functions by default in the case of SFU (pure data). It is easy to manage and can be flexibly
upgraded, expanded, and networked. The equipment has been implemented with EPON
central office equipment (Huawei / ZTE / FiberHome / Alcatel-Lucent) OLT)
interoperability, composed of Gigabit systems, to meet access needs of the two-in-one
video, data services, FTTH / FTTO.
2.1 Product Feature
Internet, CATV, IPTV service access
Equipment technical performance meets IEEE802.3ah, China Telecom CTC 2.1
& CTC3.0 standard
Support bidirectional FEC, supports the RS (255, 239) FEC decoding
Supports default SFU (pure bridged data) access

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
4
Support PPPoE, DHCP, static IP broadband service access
Support NAT, static routing, port forwarding
Support data encryption, VLAN transparent, vlan tag, vlan trunk
Support up and down traffic limit function
Supports port loop detection / port link status detection / power dying gasp alarm
Support OLT remote upgrade / WEB local upgrade function
Supports broadcast storm suppression
Support port isolate between different port.
Support port flow control
Support managed by different manufacturers OLT work as SNMP-agent. Easy to
install and maintain
Provide a variety of fault alarm function, easy to fault diagnosis
Support AES-128 decryption, support key generation and switching
Support DBA technology and priority Dual management model to ensure
minimum bandwidth requirements for users
Support CATV service remote shutdown function
Working wavelength: 1100 - 1650nm
Optical reflection loss:> 45dB
Input optical power: -18dBm ~ 0dBm
2.2 Environmental Requirements
Operation temperature:-0°C~50°C
Operation humidity:10%—90%(Non-condensing)
Power adapter input: 12V / 0.5A
Transmitted optical power: 0~4dBm
Input optical power: -3 ~ -27dBm

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
5
2.3 Product Interface Definitions
2.4 Product LED Definitions
Indicator
Description
1
PWR
Power status
On: The ONU is power on
Off: The ONU is Power off
2
LANn
LAN port status
On: Ethernet connection is normal
Blinking: Data is being transmitted through
theEthernet port
Off: Ethernet connection is not set up
3
PON
ONU Register
On: Success to register to OLT
Blinking: In process of registering to OLT
Off: Failed to register to OLT;
4
LOS
GPON optical
signals
On: Optical power lower than receiver
sensitivity ;
Off: Optical in normal
5
CATV
CATV status
On:CATV optical normal
Off:The CATV signals are not received
2.5 Device Connection
Connecting the fiber: Insert the SC fiber connector into the PON connector on
the rear panel of the ONU.
Connect the Ethernet cable: Connect the RJ-45 Ethernet cable to any LAN port

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
6
of the ONU and the home device, ie, the computer, IPTV set-top box.
Connecting the coaxial cable: Connect the coaxial cable to the RF connector of
the ONU.
Connect the AC adapter: Plug the AC / DC adapter into the AC wall jack and the
ONU 12V DC power jack.
2.6 Network Application
【1GE + CATV ONU networking applications】
3 ONU Local WEB login
3.1 ONU and PC physical Connection
a) Connect your computer's local network card to the LAN port or ETH port of the ONU via a
network cable.
b) Set the IP address of the computer's local network card to 192.168.101.X (X: 2-254).
c) The computer opens the cmd window. To ensure that the computer can ping ONU

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
7
management ip address 192.168.101.1
3.2 Computer Access ONU Local WEB
In the case # 3.1 computer can communicate with the ONU, open the
computer's Web browser (IE, Firefox, google), copy and paste the ONU access
URL: http: //192.168.101.1, pop-up as follows ONU prompt landing page:
Enter the ONU super login user: adminisp password: adminisp Click
"Login" button, there will be the following ONU main login interface:

Company Address: Room 601, Floor 6, Building F, Songbai Road 1008, Sunshine Community,Xili Street, Nanshan District, Shenzhen(518108)
Factory Address: Fl1, Bldg B, Wentao Industrial zone, Yingrenshiyongxin Village, Shiyan Street, Baoan district, Shenzhen, Guangdong, China (518055)
Tel: +86-755-26014509/4710/4711 Fax:+86-755-26014506
Website: www.cdatatec.com
8
After entering the main interface of the ONU, the ONU can be set up further. For
details, see the following setup guide.
4 ONU Registration Information Configuration
4.1 ONU Registration Status View
web login ONU select the Status ->Network interface -> PON inform, you can
check whether the ONU registered successfully:
4.2 ONU Optical Power Information View
web login ONU select the Status -> Network interface -> PON inform, you can
view the ONU input and output optical power information:
Table des matières
Autres manuels C-Data Modem
Manuels Modem populaires d'autres marques

Davicom
Davicom DM562AP Manuel utilisateur

EpiValley
EpiValley TATA indicom SXC-1080 Manuel utilisateur

Zte
Zte WiMAX Manuel utilisateur

Intelimax
Intelimax MA-2060 Manuel utilisateur

SMC Networks
SMC Networks D3CM1604V Manuel d'utilisation et d'entretien

Telstra
Telstra Wi-Fi 4G Advanced Pro X Manuel utilisateur

US Robotics
US Robotics 3453C Manuel utilisateur

MaxTech
MaxTech Plug & Play Internal Voice/FAX/Data/SVD... Manuel utilisateur

Zte
Zte MF823 Manuel utilisateur

Four-Faith
Four-Faith F1403 Manuel utilisateur

Sierra Wireless
Sierra Wireless AIRLINK MP595W Manuel utilisateur

Gemtek