C & K Systems System 236i Manuel utilisateur

P/N 5-051-371-00 Rev D
System 236 System 236i

2
ThankyouforpurchasingthisC&Kalarmsystem. Yoursystemisoneofthemostpowerful
andadvancedalarmsystemsonthemarkettoday,designedtoprovideyouwithyearsof
reliableoperation.
Thismanualexplainshowtooperateyouralarmsystem. Basicoperatinginstructionsarealso
printedonthelabelinsideyourkeypad(s)door.
Ifyouhaveanyquestionsorneedhelpwith
youralarmsystem,call:
______________________________________
______________________________________
(AlarmCompanyName)
Ifyouhavemonitoringquestionsorincases
ofaccidentalalarms,call:
______________________________________
______________________________________
(MonitoringStationName)
Whencallingthemonitoringcompany,knowthefollowing:
MyAccountNumberis:_______________________ My Password is:____________________

3
Table of contents
Gettingacquainted...............................................4-5
Whatthelightsmean...........................................6-7
Whatthesoundsmean........................................8
Armingthesystem...............................................9-15
Bypassingzones ...........................................14-15
Armingoptions .....................................................16
Disarmingthesystem ..........................................17
Afteranalarm ......................................................18
Options.................................................................19-24
ChangingaPIN .............................................20-21
DeletingaPIN ...............................................21
Resettingsmokedetectors ...........................22
Doorchime/Keypadtones...........................23-24
Testingyoursystem ............................................25-27
Telephonetrouble ................................................28
Smokedetectorplacement ..................................29
Emergencyevacuation ........................................30
Definitions ............................................................31
Limitationsofyouralarmsystem .........................32
Keypadoperations ...............................................33-35
TestProcedureIndex ..........................................36
Zonedescriptionlist .............................................37
FCCNotice ..........................................................38
IndustryCanada ..................................................39

4
What your alarm system is...
Youralarmsystemismadeupofacontrolpanelandseveraldetectiondeviceslikemotionsensors,
magneticcontacts,andsoon. Specificareasofdetectionarecalledzones. Zonescanbeprogrammedto
havedifferentcharacteristics. Somezonesmaybe24-hourzones,thatis,theyremainarmedevenwhen
thealarmsystemisoff. Zonesusedforfiredetection,forexample,arealways24-hourzones. Inaddition,
somezonescanbeprogrammedtoallowbypassing. Whenyoubypassazone,youtemporarilyremove
itfromthealarmsystem. Alwaysremember,however,that bypassedzonesarenotprotected.
How your alarm system works...
Whenadetectiondeviceistriggered,thestatusofitszonegoesfromnormaltoFAULTED. Ifarmed,
thecontrolpanelrespondsbyreportinganalarmconditiononsite---flashingkeypadlights,sounding
bells---andifprogrammed,bytransmittinganalarmsignaloverthetelephonewirestoacentral
monitoringstation. Themonitoringstationthendispatchestheappropriateauthorities.
Someofyoursystem'soperationsrequireyoutoenteryourpersonalidentificationnumber(PIN)onthe
keypad. TheseincludeARMINGandDISARMING.
Alongwithitsmanyotherfeatures,yoursystemcanbeprogrammedtoARMINSTANTLYortoARM
WITHTIMEDELAY(i.e.,aftergivingyoutimetoleavethepremises).

5
Eachalarmsysteminthe23XXfamilyisdesignedtomeetthespecificneedsofavarietyofapplications. TheSystem
236isdesignedforapplicationsrequiringprotectionofsixzones.
Someoftheavailablefeaturesofyouralarmsystemarealsooptional,andwillonlybeinstalledifappropriatefor
yourinstallation. Inaddition,somesystemfeatureswillrequireyoutoenteryourpersonalidentificationnumber
(PIN).
Asyoureadthroughthismanual,watchforboxeslikethese:
Ifanoptionalfeaturehasbeeninstalledinyoursystem,its
OPTION INSTALLED box will be checked.
.
.Ifafeatureofyoursystemrequiresyoutoenteryourpersonal
identificationnumber,itsPINREQUIREDboxwillbechecked.
OPTION
INSTALLED PIN
REQUIRED

6
off onsteady Powerfail.Systemonbattery.
onsteady Readytoarm.
off onsteady Oneormorezonesarefaulted.
off* onsteady *Readylightwillbeonuntilsystemisarmed.
off slowflash Armedwith
7#
.
on* off *Readylightisonifallzonesarenormal.
slowflash onsteady slowflash* Armedwith
4#
.
*Flashingzonesarebypassed.
AC FAILURE
SYSTEM IS READY
(ALL ZONES NORMAL)
FAULTED ZONE
WHILE DISARMED
SYSTEM IS ARMED
(ALL PROTECTION ON)
PERIMETER ARMED
WITH DELAYS INTACT
POWER
LIGHT READY
LIGHT ARMED
LIGHT REMARKS
SYSTEM IS DISARMED
(ALL PROTECTION OFF)
SYSTEM IS ARMED
WITH DELAY ZONES
CONVERTED TO INSTANT
SERVICE
LIGHT ZONES
LIGHTS

7
slowflash slowflash slowflash Systemisinprogrammingmode.
fastflash Callforservice.
onsteady Callforservice.
slowflash onsteady Callforservice.
slowflash slowflash Readyandbypassedzoneflashatthe
samerate.
slowflash slowflash Serviceandzoneintrouble.
Flashatthesamerate.
slowflash slowflash slowflash* Armedwith
4 7#
.
*Flashingzonesarebypassed.
COMMUNICATIONS
FAILURE
WATCHDOG RESET
BELL FUSE FAILURE
LOW BATTERY
ZONE BYPASSED
ZONE(S) IS OR
WAS IN ALARM
ZONE TROUBLE
PERIMETER ARMED
WITH DELAY ZONES
CONVERTED TO INSTANT
POWER
LIGHT READY
LIGHT ARMED
LIGHT REMARKS
SERVICE
LIGHT ZONES
LIGHTS
PROGRAMMING
MODE
slowflash on* fastflash Analarmhasoccurredonthiszone.
*Armedlightisonifthesystemisarmed.
slowflash Panelhasresetitself.SystemOK.Toresetthe
Service Light, press * 1 #.

8
SOUND MEANING
2beeps(confirmationtones) systemarmedordisarmed
.successfulcentralstationtestorbatterytest
.
pulsedtone(2secondson,2secondsoff) zoneprogrammedforpulsedbellorsirenisinalarm
.
continuoustone zoneprogrammedforsteadybellorsirenisinalarm
circuitmalfunction(troubleonsupervisedloopsonly)
.
.
.
5beeps(errortones) invalidfunction
unauthorizedcommandattempted
errorchangingPINnumber
wrongPINnumberentered
.
.
.
zoneprogrammedforchirpingbellorsirenisinalarm
.
chirping(1secondon,4secondsoff)
zonefaultedduringwalk-test
.
2secondbeep doorchime
.
continuousbeeping,speedingupforlasttenseconds exitdelaytime
.
.
continuoustone,beepingfastforlasttenseconds entrydelaytime

9
Make sure the green READY light is on.
Faultedzonesmustbeclearedorbypassedbeforethesystemcanbearmed. Formore
information,refertothesectionsBypassingZonesandAfterAnAlarmOccurs.
TO ARM THE SYSTEM / AUTO HOME ARMING:
.
Ifprogrammed,theredZONElightswillautomaticallyturnoffafterfiveminutes(asa
securitymeasure). PressinganykeyonthekeypadwillturntheZONElightsbackon.
.
OPTION
INSTALLED
YourPINnumberisfourdigitslong.
Don'tpauseformorethan5secondswhileenteringthedigitsorthecontrolpanelwill
rejectyourPINnumber.
Enter your PIN and push the
#key.
.
.
PIN
REQUIRED
IfyoumakeamistakewhileenteringyourPINnumber,thekeypadwillbeepfivetimes.
Afterthefifthbeep,enteryourPINnumberagain.
.
Make sure the red ARM light comes on.
Thekeypadwillbeeptwicetoconfirmthatthesystemisarmed.
.

10
Exit through any TIME DELAY DOOR within seconds.
Theexitdelaytimecanbeprogrammedfrom10secondsto150seconds.
.
.Oncetheexitdelaytimehasexpired,thekeypadwillbeeptwicetoconfirmthatthe
systemisarmed.
IftheEXITPRE-ALARMoptionisinstalled,thekeypadwillbeepslowlyuntil10seconds
beforethedelaytimeexpires,thenrapidlyforthelast10seconds.
.
OPTION
INSTALLED
TherestoftheARMINGTHESYSTEMsectionexplainshowtobypasszonesbeforearmingthesystem,aswellas
certainarmingoptionsourinstallercaninstall. However,it'simportantforyoutorememberthatnomatterhowyour
system is programmed, you will always disarm it in the same way: enter your PIN, then push the # key.
OPTION
INSTALLED TheAUTOHOMEARMINGoptionenablesthesystemtoautomatically
bypassinteriorzonesifyouarmthesystembutdonotleavethepremises.
Theperimeterzoneswillbearmedandtheentrydelaywillremainintact.
With this option installed, arm the system (enter your PIN and push the # key).
.Ifyoudonotexitbeforetheexitdelaytimeexpires,thesystemwillautomaticallyarm
perimeterzonesandbypassinteriorzones.
.Ifyouexitthroughanexitdelaydoor,thesystemwillautomaticallyarminteriorand
perimeterzones.
Autres manuels pour System 236i
1
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels C & K Systems Clavier