BWS PROFESSIONAL II Series Manuel utilisateur

OPERATIONS MANUAL
RESIDENTIAL FILTRATION SYSTEMS
WITH FLECK 2510 AIO CONTROL VALVE
PROFESSIONAL II SERIES
MODEL NO. ______________________
SERIAL NO. ______________________
The Blake Group
BWS
TM

INSTALLATION INFORMATION
DATEINSTALLED:_________________________________
MEDIATANKSIZE:______________”X________________”
MEDIAINSTALLED________________________________QTY
WELLPUMPCAPACITY:____________________________GPM
PIPESIZE:__________”MATERIAL_____________________
SERVICEFLOW:__________________________________GPM
BACKWASHFLOW:_______________________________GPM
CURRENTWATERCONDITIONSATSTARTUP
WATERTESTRESULTS:IRON________________________PPM
WATERTESTRESULTS:MANGANESE_________________PPM
WATERTESTRESULTS:HYDROGENSULFIDE___________PPM
WATERTESTRESULTS:FEEDWATERpH___________________
WATER SAMPLE INFORMATION
City Water Supply Private Water Supply FEEDWATER IS Clear Cloudy
OBJECTIONABLE CHARACTERISTICS OF WATER SUPPLY
Water Seems Hard Water Has Sulfur Odor
Water Makes Red Stains Water Has Other Bad Taste and/or Odor
Water Makes Blue/Green Stains White Build-Up on Chrome Fixtures
Water Looks Dirty/Cloudy Water Heater Coils Clog/Burn-Out
Slimy Build-Up in Toilet Tank Other

Introduction
The Aeration lter system functions as a regenerable water treatment unit utilizing oxygen
instead of potentially harmful chemicals to rejuvenate and enhance the performance of the
selective ltration media. The ltration media provided is specic to the water contaminant or
contaminants your water treatment specialist has identied.
The Fleck 2510 AIO (Aerating Iron Oxidizer) Control Valve utilizes an air injection system to
remove iron (ferrous or clear water), manganese, and sulfur from the water by both oxidation
and ltration. Unlike other iron lter alternatives, the Fleck 2510 AIO technology is designed
for use in a single tank and valve system conguration, reducing both initial and maintenance
costs yet delivering years of trouble-free service. No chemical additives or air compressors are
required for operation or regeneration with the Fleck 2510 AIO’s unique and advanced design.
Do not use where water is microbiologically unsafe.
Installation Requirements
WATER PRESSURE: A minimum of 30 psi of water pressure (2.7bar) is required for
regeneration valve to operate effectively.
CAUTION: Water pressure must not exceed 80psi (5.5 bars), water temperature is not to
exceed 110°F (43°C), and the unit cannot be subjected to freezing conditions.
NOTE: Due to the air pocket, exceeding 80PSI will adversely impact performance.
ELECTRICAL FACILITIES: An uninterrupted 120 volt (A/C) supply is required. The valve is
supplied with a 24vac transformer.
Please make sure your voltage supply is compatible with your unit before installation.
EXISTING PLUMBING: Condition of existing plumbing should be free from scale and iron
buildup. Piping that is built up heavily with scale and/or iron should be replaced.
LOCATION OF OXIDIZER AND DRAIN: The oxidizing lter should be located close to a drain
to prevent air breaks and back ow.
The oxidizing lter should be installed ahead of any water softeners.
BY-PASS VALVES: Always provide for the installation of a by-pass valve if unit is not equipped
with one.
1

Installation Instructions
1. Place the oxidizer tank where you want to install the unit making sure the unit is level and on
a rm base.
2. During cold weather, the installer should warm the valve to room temperature before
operating.
3. All plumbing must be done in accordance with local plumbing codes. The pipe size for
residential drain line should be a minimum of 1/2” (13 mm). Backwash ow rates in excess of
7 gpm (26.4 L/pm) or length in excess of 20’ (6 m) require 3/4” (19 mm) drain line. Commercial
drain lines should be the same size as the drain line ow control. Due to the release of
the air during regeneration, the drain line must be secured at the end, and anchored
throughout the run.
4. The check valve supplied with the valve must be installed at the valve inlet to prevent the
pressurized air head in the oxidizer tank from venting backwards up the feed water plumbing.
5. If not factory installed assemble the deflector to the distributor tube.
Deflector Installation:
Put a thin layer of silicone lube around inside diameter of the deflector. Slowly slide the deflector
over the distributor tube down about 1”. When threading the AIO valve to the tank, the bottom
of the threads will slide the deector down. As shown above.
6. Lubricate the distributor O-ring seal and tank O-ring seal. Place the main control valve on
tank.
Note: Only use silicone lubricant.
7. Solder joints near the drain must be done prior to connecting the Drain Line Flow Control
tting (DLFC). Leave at least 6” (15 cm) between the DLFC and solder joints when soldering
pipes that are connected on the DLFC. Failure to do this could cause interior damage to the
DLFC.
8. Teon® tape is the only sealant to be used on the drain tting. Do not use pipe dope or
other compounds as they contain petrochemical elements and will attack the drain housing
and cause failure.
2

9. Place the bypass valve in the by-pass position. Turn on the main water supply. Open a
cold ltered water tap nearby and let run a few minutes or until the system is free from foreign
material (usually solder) that may have resulted from the installation. Once clean, close the
water tap.
10. Note this system is supplied without media installed for ease of transportation and
simplifying site location. Refer to the section of this manual for Media Filtration installation
Guide/Commissioning.
11. Plug unit transformer into an electrical outlet. Note: All electrical connections must be
connected according to local codes. Be certain the outlet is continually powered (unswitched/
uninterrupted).
CONTROLLER
NOTE: The electronic control is preset at the factory so that it will begin regeneration at
12:00 A.M. every third day. This ensures the right times for each step of the regeneration
process. Under normal circumstances, these settings will not need to be altered and
should not be changed.
The frequency and time of regeneration can be changed due to the following reasons:
• A need for the unit to regenerate at a different time of day (DO NOT regenerate any other
softener/lter at the same time as the AIO, since this will interfere with the regeneration
process). Allow for a sufcient delay between the regeneration of equipment downstream of
this lter for water recovery in low yielding wells.
• In conditions of high water usage and/or high levels of iron, the unit may need to regenerate
more frequently than once every three days. The unit can be set for daily regeneration or
to regenerate every two days. It is not advisable in most instances to set the regeneration
frequency for a longer period than 3 days, as the lter medium can become fouled with iron,
rendering the unit ineffective.
3

CONTROLLER
Timer Operation
In normal operation, the Time of Day display will alternate being viewed with the Days
Remaining display. This display will be in gallons (options are liters or cubic meters). As treated
water is used, the Days Remaining display will count down from a maximum value to zero or
(- - -). Once this occurs, a regeneration cycle will be initiated at the Set Regeneration Time.
Water ow through the valve is indicated by the Flow Indicator that will ash in direct
relationship to ow rate.
Time Clock Delayed Control (Factory Default Setting)
A Time Clock Delayed Control regenerates the system on a timed interval. The control will initi-
ate a regeneration cycle at the programmed regeneration time when the number of days since
the last regeneration equals the regeneration day override value.
4

Day of the Week Control
This control regenerates the system on a weekly schedule. The schedule is dened in Master
Programming by setting each day to either “off” or “on.” The control will initiate the regeneration
cycle on the days that have been set to “on” at the specied regeneration time.
Control Operation during Regeneration
During regeneration, the control displays a special regeneration display. In this display, the
control shows the current regeneration step number the valve is advancing to, or has reached,
and the time remaining in that step. The step number that displays ashes until the valve
completes driving to this regeneration step position. Once all regeneration steps are complete
the valve returns to service and resumes normal operation.
Pressing the Extra Cycle button during a regeneration cycle immediately advances the valve to
the next cycle step position and resumes normal step timing.
Control Operation during Programming
The SXT control only enters the Program Mode with the valve in service. While in the Program
Mode, the control continues to operate normally monitoring water usage and keeping all
displays up to date. Control programming is stored in memory permanently, eliminating the
need for battery backup power.
Control Operation during a Power Failure
The SXT includes integral power backup. In the event of power failure, the control shifts into a
power-saving mode. The control stops monitoring water usage, and the display and motor shut
down, but it continues to keep track of the time and day for a minimum of 48 hours.
The system conguration settings are stored in a non-volatile memory and are stored
indenitely with or without line power. The Time of Day ashes when there has been a power
failure. Press any button to stop the Time of Day from ashing.
If power fails while the unit is in regeneration, the control will save the current valve position
before it shuts down. When power is restored, the control will resume the regeneration cycle
from the point where power failed. Note that if power fails during a regeneration cycle, the
valve will remain in its current position until power is restored. The valve system should include
all required safety components to prevent overows resulting from a power failure during
regeneration.
The control will not start a new regeneration cycle without line power. If the valve misses a
scheduled regeneration due to a power failure, it will queue regeneration. Once power is
restored, the control will initiate a regeneration cycle the next time that the Time of Day equals
the programmed regeneration time. Typically, this means that the valve will regenerate one day
after it was originally scheduled. If the treated water output is important and power interruptions
are expected, the system should be setup with a sufcient reserve capacity to compensate for
regeneration delays.
5

Setting the Time of Day
1. Press and hold either the Up or Down buttons until the programming icon replaces the
service icon and the parameter display reads TD.
2. Adjust the displayed time with the up or down button.
3. When the desired time is set, press and release the Extra Cycle button to resume normal
operation. The unit will also return to normal operation after 5 seconds if no buttons are
pressed.
Regeneration Options:
Queuing a Delayed Regeneration
1. Press and release the Extra Cycle button once. The service icon will ash to indicate that
the regeneration is queued to occur at the next selected regeneration hour.
2. To cancel a queued regeneration, press and release the Extra Cycle button again. The
service icon will stop ashing.
Regenerating Immediately
Press and hold the Extra Cycle button for ve seconds.
1. The timer advances to Regeneration Cycle Step #1 (backwash), and begins
programmed time count down. Default Factory set at 14 minutes.
2. Press and release the Extra Cycle button once to advance valve to Regeneration
Cycle Step #2 (brine draw & slow rinse). Default Factory set at 40 minutes
3. Press and release the Extra Cycle button once to advance valve to Regeneration
Cycle Step #3 (rapid rinse). Default Factory set at 1 minute
4. Press and release the Extra Cycle button once to advance valve to Regeneration
Cycle Step #4 (brine rell). Default Factory set at OFF
Press and release the Extra Cycle button once more to advance the valve back to in service.
NOTE: Any regeneration cycle step can be advanced to the next step by pressing and
releasing the cycle button
6

Regeneration Cycle (55 minutes):
Automatic Bypass during Regeneration
The lter is factory set to regenerate at 12:00 a.m., normally a period of little or no water use.
The regeneration cycle lasts approximately 55 minutes, after which ltered water service is
restored.
While the regeneration cycle is in progress raw water will automatically bypasses the lter if
required. If possible, avoid using water during this time to prevent untreated water entering
your household plumbing system.
The programmed regeneration time may be changed to accommodate households with varying
schedules, however once set to meet water quality requirements the cycle duration times
should not be changed.
1. Backwash (14 minutes):
During this cycle, the water carrying the iron runs to the drain. Untreated water is available
during regeneration.
2. Air Recharge (40 minutes):
During this cycle, the unit empties water to drain and is recharged with air. The sound of air
being recharged will be heard. Air bubbles should go down to the drain before proceeding to
the next step. Adjust cycle time if necessary.
3. Rapid Rinse (1 minute):
During this cycle, water enters the tank, compressing the air into a pocket at the top of the
tank.
4. Brine Fill (OFF)
7

SXT Programming Selections for Aeration Systems:
Note the system as supplied is preprogrammed to reect all parameters listed below
Entering Master Programming Mode
Set the Time of Day display to 12:01 P.M.
Press and release the Extra Cycle button (to exit Setting Time of Day mode).
Then press and hold the Up and Down buttons together until the programming icon replaces
the service icon and the Display Format screen appears.
Programming
Abbreviation
Programming Denition *Option Abbreviation Option Denition
DF Display Format GAL Gallons -12 hour time
VT Valve Type DF 1b Downow-Single Backwash
CT Control Type tc Time Clock-Regenerates based
on days
NT Number of Tanks 1 Single Tank
DO Day Override 3 Days between Regenerations
RT Regeneration Time 12:00 AM Regeneration Time
BW Backwash 14 Minutes for Backwash Cycle
BD Air Draw 40 Minutes for Air Draw Cycle
RR Rapid Rinse 1 Minute for Rapid Rinse Cycle
BF Brine Fill Off Not a function used for this valve
*factory default
Exiting Master Programming Mode
Press and release the Extra Cycle button to accept the displayed settings and cycle to the next
parameter. Press and release the Extra Cycle button at the last parameter to save all settings
and return to normal operation. The control will automatically disregard any programming
changes and return to normal operation if it is left in Master Programming mode for 5 minutes
without any keypad input.
Refer to Fleck SXT Timer service manual 42713 for information on the following:
- Viewing Diagnostics
- Programming Options
- Troubleshooting
- Parts List
8
Table des matières
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur