Buhler TF Series Manuel utilisateur

Fluidcontrol
Installation and Operation Instructions
Original instructions
Temperature sensor/switch
TF, TS, Thermolog
BE140006
11/2019
Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen
Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20
E-Mail: [email protected]
Internet: www.buehler-technologies.com

Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen
Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20
Internet: www.buehler-technologies.com
E-Mail: [email protected]
Read this instruction carefully prior to installation and/or use. Pay at-
tention particularly to all advises and safety instructions to prevent in-
juries. Bühler Technologies can not be held responsible for misusing
the product or unreliable function due to unauthorised modifications.
All rights reserved. Bühler Technologies GmbH 2020
Document information
Document No..........................................................BE140006
Version...........................................................................11/2019

TF, TS, Thermolog
Contents
1 Introduction..................................................................................................................................................................................................................... 2
1.1 Intended Use.........................................................................................................................................................................................................2
1.2 Model key............................................................................................................................................................................................................... 2
2 Safety instructions.........................................................................................................................................................................................................4
2.1 Important advice.................................................................................................................................................................................................4
2.2 General hazard warnings ................................................................................................................................................................................. 5
3 Transport and storage ..................................................................................................................................................................................................6
4 Setup and Connection .................................................................................................................................................................................................. 7
5 Operation and control ..................................................................................................................................................................................................8
5.1 TF-M-Pt100/TF-E-Pt100/TF-M-Pt100-VAL Temperature Sensor.............................................................................................................8
5.2 TSM/TSK/TSA Bi-Metal Temperature Switch..............................................................................................................................................8
5.3 Thermolog MK2/EK2 Temperature Sensor with 4-20mA Output.........................................................................................................8
6 Maintenance and repair ..............................................................................................................................................................................................9
7 Service and repair......................................................................................................................................................................................................... 10
8 Disposal............................................................................................................................................................................................................................ 11
9 Appendix..........................................................................................................................................................................................................................12
9.1 Technical data .................................................................................................................................................................................................... 12
9.1.1 TF and Thermolog Temperature Sensor ...................................................................................................................................... 12
9.1.2 TSA, TSK and TSM Temperature Switch .......................................................................................................................................12
9.2 Pin Assignment...................................................................................................................................................................................................13
9.2.1 TF-M-Pt100/TF-E-Pf100/TF-M-Pt100-VAL Temperature Sensor ............................................................................................ 13
9.2.2 Thermolog MK2/EK2 Temperature Sensor with 4-20 mA Output ....................................................................................... 13
9.2.3 TSA/TÖA Bi-Metal Temperature Switch....................................................................................................................................... 13
9.2.4 TSM/TSK Bi-Metal Temperature Switch ......................................................................................................................................14
10 Attached documents....................................................................................................................................................................................................15
iBühler Technologies GmbHBE140006 ◦ 11/2019

TF, TS, Thermolog
1 Introduction
1.1 Intended Use
Temperature sensors can be used to monitor the temperature of a fluid within a tank.
These operating instructions describe several temperature switches / sensors types in one, as many descriptions identical or
similar.
Please refer to the type plate to identify your model. In addition to the job number it also contains the item number and model
designation.
If a model has special features, these are described separately in the operating instructions.
WARNING
All device models are solely intended for industrial applications. They are not safety com-
ponents. The devices must not be used if failure or malfunction thereof jeopardises the
safety and health of persons.
Use in explosive areas is prohibited.
DANGER Explosion hazard when used in explosive areas
Use in explosive areas is prohibited.
1.2 Model key
Model key for TF temperature probe
Version
MS
VA
(max. 1000 mm)
Length
TF-M
TF-E
Brass
Stainless steel
Switching type
TF-M for version MS
------------ ------------
------------ ------------
2 lead
2L =
TF-E for version with VA
Plug connection
M3
M12
GS4 for 4 lead only
3L =
4L =
3 lead
4 lead
Model key for temperature sensor MK 2/EK 2
Version
MS
VA
(max. 1000 mm)
Length
MK
EK
Brass
Stainless steel
Plug connection
M12
MK2 for version with MS
------------ ------------
------------
M3
EK2 for version with VA
2 Bühler Technologies GmbH BE140006 ◦ 11/2019

TF, TS, Thermolog
Typenschlüssel für Temperaturfühler TSM/TSE
Number of temperature contacts
1 or 2
(max. 1000 mm)
Length
TSM
TSE
TSM for version MS
------------ ------------
------------ ------------ ------------ ------------
TSE for version with VA
Version
MS
VA
T1 (1st temperature contact)
NO contact
NC contact
50 °C
60 °C
70 °C
80 °C
TM50NC
TM60NC
TM70NC
TM80NC
TM50NO =
TM60NO =
TM70NO =
TM80NO =
Brass
Stainless steel
Plug connection
M3
M12
T2 (2nd temperature contact)
NO contact
NC contact
50 °C
60 °C
70 °C
80 °C
TM50NC
TM60NC
TM70NC
TM80NC
TM50NO =
TM60NO =
TM70NO =
TM80NO =
Model key for temperature sensor TSK
Number of temperature contacts
1 or 2
(max. 1000 mm)
Length
TSK ------------ ------------
------------ ------------ ------------ ------------
Version
MS
VA
T1 (1st temperature contact)
NO contact
NC contact
40 °C
50 °C
60 °C
70 °C
80 °C
TM40NC
TM50NC
TM60NC
TM70NC
TM80NC
TM40NO =
TM50NO =
TM60NO =
TM70NO =
TM80NO =
Brass
Stainless steel
Plug connection
M3
M12
T2 (2nd temperature contact)
NO contact
NC contact
40 °C
50 °C
60 °C
70 °C
80 °C
TM40NC
TM50NC
TM60NC
TM70NC
TM80NC
TM40NO =
TM50NO =
TM60NO =
TM70NO =
TM80NO =
3Bühler Technologies GmbHBE140006 ◦ 11/2019

TF, TS, Thermolog
2 Safety instructions
2.1 Important advice
Operation of the device is only valid if:
– the product is used under the conditions described in the installation- and operation instruction, the intended application
according to the type plate and the intended use. In case of unauthorized modifications done by the user Bühler Technolo-
gies GmbH can not be held responsible for any damage,
– when complying with the specifications and markings on the nameplates.
– the performance limits given in the datasheets and in the installation- and operation instruction are obeyed,
– monitoring devices and safety devices are installed properly,
– service and repair is carried out by Bühler Technologies GmbH,
– only original spare parts are used.
This manual is part of the equipment. The manufacturer keeps the right to modify specifications without advanced notice. Keep
this manual for later use.
Signal words for warnings
DANGER
Signal word for an imminent danger with high risk, resulting in severe injuries or death if not avoided.
WARNING
Signal word for a hazardous situation with medium risk, possibly resulting in severe injuries or death if not
avoided.
CAUTION
Signal word for a hazardous situation with low risk, resulting in damaged to the device or the property or
minor or medium injuries if not avoided.
NOTICE
Signal word for important information to the product.
Warning signs
These instructions use the following warning signs:
Warns of a general hazard Unplug from mains
Voltage warning Wear respiratory equipment
Warns not to inhale toxic gasses Wear a safety mask
Warns of corrosive liquids Wear gloves
General information
4 Bühler Technologies GmbH BE140006 ◦ 11/2019

TF, TS, Thermolog
2.2 General hazard warnings
The equipment must be installed by a professional familiar with the safety requirements and risks.
Be sure to observe the safety regulations and generally applicable rules of technology relevant for the installation site. Prevent
malfunctions and avoid personal injuries and property damage.
The operator of the system must ensure:
– Safety notices and operating instructions are available and observed,
– The respective national accident prevention regulations are observed,
– The permissible data and operational conditions are maintained,
– Safety guards are used and mandatory maintenance is performed,
– Legal regulations are observed during disposal,
– compliance with national installation regulations.
Maintenance, Repair
Please note during maintenance and repairs:
– Repairs to the unit must be performed by Bühler authorised personnel.
– Only perform conversion-, maintenance or installation work described in these operating and installation instructions.
– Always use genuine spare parts.
– Do not install damaged or defective spare part. If necessary, visually inspect prior to installation to determine any obvious
damage to the spare parts.
Always observe the applicable safety and operating regulations in the respective country of use when performing any type of
maintenance.
5Bühler Technologies GmbHBE140006 ◦ 11/2019

TF, TS, Thermolog
3 Transport and storage
Only transport the product inside the original packaging or a suitable alternative.
The equipment must be protected from moisture and heat when not in use. It must be stored in a covered, dry, dust-free room
at room temperature.
6 Bühler Technologies GmbH BE140006 ◦ 11/2019

TF, TS, Thermolog
4 Setup and Connection
DANGER Toxic, corrosive gasses
The sample gas can be harmful to the health if inhaled or on contact.
a) Ensure harmful gases are discharged safely.
b) Switch off the gas supply before performing maintenance and repairs, and flush the
gas lines with air. Secure the gas supply from accidentally being opened.
c) Protect yourself from toxic / corrosive gasses when performing maintenance. Wear
suitable protective equipment.
The temperature switch / sensor come complete and can be screwed onto the container with the thread. The maximum torque
of the screw-in thread is 25Nm.
When installing, be sure the sealing face is clean and even. Only screw the temperature switch / sensor into the fitted thread.
Sealed with an elastic sealing ring. No other sealants required.
7Bühler Technologies GmbHBE140006 ◦ 11/2019

TF, TS, Thermolog
5 Operation and control
DANGER Electric voltage
Risk of electric shock
a) Disconnect the unit from the mains when performing any maintenance.
b) Secure the equipment from accidental restarting.
c) The unit may only be maintained and opened by instructed, competent personnel.
The pin assignment for the respective models are listed in chapter Pin Assignment [> page13].
5.1 TF-M-Pt100/TF-E-Pt100/TF-M-Pt100-VAL Temperature Sensor
Type TF temperature sensors use a Pt100 temperature sensor per DIN/IEC751 class B to generate a temperature-dependent res-
istance signal. The Pt100 sensor is installed at the lowest point of the sensor tube to always ensure sufficient contact with the
medium being measured.
The temperature sensor TF-M-Pt100-VAL was designed for measuring storage temperatures and has a spring-loaded sensor
tube to allow installation free of play with a constant contact pressure at the measuring point.
5.2 TSM/TSK/TSA Bi-Metal Temperature Switch
The TS temperature sensors have a bi-metal temperature switch to signal a set temperature value. Unlike the TSM standard ver-
sion, the TSK and TSA versions with bi-metal switches have a lower hysteresis.
The TSA version is further specifically designed for installation in tube systems and cooling matrices.
The bi-metal switch is installed at the lowest point of the sensor tube to always ensure sufficient contact with the medium be-
ing measured.
5.3 Thermolog MK2/EK2 Temperature Sensor with 4-20mA Output
Type MK2 and EK2 temperature sensors use a Pt100 temperature sensor per DINEN/IEC60751 Class B to generate a temperat-
ure-dependent resistance signal.
The built-in electronics convert this resistance signal into a standard 4-20 mA two-lead signal.
The Pt100 sensor is installed at the lowest point of the sensor tube to always ensure sufficient contact with the medium being
measured.
8 Bühler Technologies GmbH BE140006 ◦ 11/2019
Autres manuels pour TF Series
1
Ce manuel convient aux modèles suivants
10
Table des matières
Autres manuels Buhler Régulateurs de température
Manuels Régulateurs de température populaires d'autres marques

Swegon
Swegon LUNAd MB Manuel utilisateur

Lucky Reptile
Lucky Reptile Thermo Control II Manuel utilisateur

SENSORMETRIX
SENSORMETRIX Argon 100 Manuel utilisateur

Fuji Electric
Fuji Electric PXE4 Manuel utilisateur

Yuyao gongyi
Yuyao gongyi XMT-808 series Manuel utilisateur

Selec
Selec TC544C Manuel utilisateur