Opti-FloII Upgrade Kit 3 9E-832
13. Usingthenewwiringlabelasaguide,connectthesolid
brown,redandorangewiresfromtheinputfiltertothe
properterminalblocklocationsoftheOpti-FloIImain
terminal block (see Figures 1,2 and Table 2).
12. Usingthenewwiringlabelasaguide,removeexisting
wires from the Opti-Flo II main terminal block and
install the proper wire from the new wire harness
coming from the GPD 315 (see Table 3). The wire
colorsbetweenthenewandexistingwireharnessare
essentiallythesametohelptheinstallationandeliminate
confusion. Theoldwireharnessistobediscarded(see
Figure1).
14. Atthispointallwiringshouldbecompleted.Insureall
wiresaresecurelyinstalled.Usingthenewwiringlabel,
doublechecktoverifythatallwiresareinstalledatthe
properlocations(seeFigure2).
— IMPORTANT ——————————————––––––––––
Miswiring will cause damage to the Magnetek GPD 315.
3. Verifying Proper Operation
1. Refer to Figure 3 for a function block diagram.
2. VerifythatallReceiverProbesareintheOFFposition
and that there is an OPEN between Receiver Probe
COMMON ( J3 ) and the LOW, MEDIUM, and HIGH
Receiver probe inputs ( J5, J6, and J7 ).
3. Switch“ON”powerfrom the breaker tothe
Opti-Flo II.
4. Thecontrolshouldcomeupwiththegreen“RUN”LED
flashing,thegreen“FOUT”LEDONcontinuously,the
red4digitdisplayshowing“0.00” andthered“ALARM”
LEDOFF.
5. The Magnatek GPD 315 parameters can be viewed
and programmed by using the Digital Operator (see
Figure1).Pressthe“DSPL”keyuntilthegreen“PRGM”
LED turns ON. Each parameter starts with the small
letter “n” and is followed by a 3 digit number. The red
4 digit display will display “nXXX” where XXX is a
numberbetween001and179.Usethe“^”(UP)keyto
incrementupandthe (DOWN)keytoincrementdown
dependingonwhich parameter you are interestedin.
Once you get to the desired parameter press the
“DATA/ENTER” key to display the present value
programmedintotheparameter.Tochangeorprogram
thedesiredparameterusethe“^”(UP)keytoincrement
upandthe (DOWN)keytoincrementdowndepending
onwhatvalueyouwanttoprogramintothatparameter.
Once the desired value is being displayed press the
“DATA/ENTER”keytostorethedesiredvalueintothe
parameter.Afterallparameterprogrammingiscomplete
pressthe“DSPL”keyuntilthegreen“FOUT”LEDturns
ON. A listing of installation specific parameters is
givenin Table 4. A completelistofall the parameters
can be found in Table A1-1.
—NOTE——————————————–––––––––––––––––
The parameters listed in Table 4 are the ONLY ones that may
need to be reprogrammed for proper operation. Of these,
Parametern036,“MotorRatedCurrent”isthesetfora1HpBou-
Matic milk pump motor and MUST be reprogrammed per the
motor nameplate to insure proper operation.
6. Activatethemanualpumpoutswitch.Themilkpump
motorshouldstartrunning. Verifythat the milk pump
isrotatinginthecorrectdirection. Ifitisnot,turn“OFF”
the breaker and check the wiring of the motor.
7. Aftercheckingmotordirection,checkthefloatswitches
forproperoperation.Thelowfloatshouldrunthemotor
at50Hz. Thehighfloatshouldrunthemotorat60Hz.
If an optional middle float switch is used, it will be
preset to run at 55 Hz. Check each float individually.
8. Check the Milk/Wash switch for proper operation. All
floatswitchesshouldbeloweredandthemotorshould
gnimmargorP513DPG:4elbaT
retemaraP foemaN noitcnuF tnemmoC citaM-uoB tluafeD
110n mumixaM ycneuqerF
rePteS rotoM etalpemaN zH06
210n mumixaM egatloV
rePteS rotoM etalpemaN stloV032
120n noitareleccA 2emiT
=,#rehgiH emitregnol tnioptesot .ceS4
220n noitareleceD 2emiT
=,#rehgiH emitregnol tnioptesot .ceS01
420n ycneuqerF 1ecnerefeR
ycneuqerF WOLrof EBORP zH05
520n ycneuqerF 2ecnerefeR
ycneuqerF MUIDEMrof EBORP ZH55
720n ycneuqerF 4ecnerefeR
ycneuqerF HGIHrof EBORP zH06
630n detaRrotoM tnerruC
rePteS rotoM etalpemaN spmA8.2