Bifinett KH 525 Manuel utilisateur

Kompernaß GmbH · Burgstrasse 21 · D-44867 Bochum
www.kompernass.com
ID-Nr.: 526-07-2006-V1
UK
KH525_IB_UK 06.07.2006 10:15 Uhr Seite 1

Blender KH 526
Instruction Booklet
KH525_IB_UK 06.07.2006 10:16 Uhr Seite 2

KH525_IB_UK 06.07.2006 10:16 Uhr Seite 3

KH 526
KH525_IB_UK 06.07.2006 10:16 Uhr Seite 4

KH525_IB_UK 06.07.2006 10:16 Uhr Seite 5

KH525_IB_UK 06.07.2006 10:16 Uhr Seite 6

- 3 -
KH 526
Blender
Introduction 4
Proper use 4
Technical data 4
Description 4
Before start-up 4
Safety 5
Important safety instructions 5
To avoid life-threatening electric shocks: 5
In order to avoid the danger of fire and/or injuries: 5
A safe approach: 6
Operation 6
Installing the mixing unit 6
Food processing 6
Selecting the suitable speed level. 6
Utilizing the whole range of applications 7
Useful tips 8
Cleaning 8
Disposal 9
Information 9
Keep this manual for future reference and pass it on with the equipment to any
future users.
KH525_IB_UK 06.07.2006 10:16 Uhr Seite 3

- 4 -
KH 526
Blender KH 526
Introduction
Estmeemed Customer,
Our products are designed to fulfil the
highest requirements of quality, functio-
nality, and design. We hope that you will
enjoy using your new “BIFINETT“ appli-
ance.
Proper use
The appliance is suitable for mixing, pu-
reeing, kneading/ stirring and emulsify-
ing various types of foodstuffs. This ap-
pliance can be used even to cut and
crush ice.
You will find the exact procedures and
corresponding output levels in the sec-
tion entitled “Food processing”.
Cores, large seeds and stems/ stalks must
be removed before feeding the food-
stuffs into the appliance.
Only original attachments and accesso-
ries, as described , may be used.
Any other usage or changes count as
contrary to instructions and harbour
great danger of accidents. The manufac-
turer takes no responsibility for dama-
ge(s) arising out of usage that is contrary
to the instructions laid down.
Not for commercial use.
Technical data
Rated voltage: 220-240 V ~
50 Hz
Rated output: 600 Watt
KB time: 2 Minutes
Capacity of the
mixing unit: 1.7 l
Max. capacity: 1.5 l
Description
Measuring cup
Lid
Mixing unit
Cutting blade
Mounted motor unit
Switch
Before start-up
Carefully clean all the component
parts before using the blender for the
first time. (see section: Cleaning).
Connect the appliance to the power
source.
KH525_IB_UK 06.07.2006 10:16 Uhr Seite 4

- 5 -
Safety
Important safety instructions
The following safety instructions must
always be adhered to when using elec-
trical appliances:
These directions will help you avoid
severe injuries and/or heavy damage(s),
and enable you to achieve better results
and/or output.
Please read the following information
regarding safety measures and appropri-
ate usage carefully. Open the page with
the illustrations before you begin
reading and make yourself familiar with
all the functions of the appliance.
Preserve these directions carefully and
pass them on, if and when necessary, to
others too.
To avoid life-threatening electric shocks:
• The voltage of the power source must
match the stipulations given on the
plate with the details of the model
affixed to the appliance. Appliances
requiring 220-240 V.
• Never immerse the mounted motor
unit in water. Wipe it instead with a
damp cloth to clean it.
• Never operate the appliance with a
damaged connecting cable or power
plug. Immediately have the damaged
connecting cables and/or appliances
that do not function optimally, or we-
re damaged, inspected and repaired
by the authorized customer service.
• Do not expose the appliance to the
rain and never use it in a humid or
wet environment. Make sure that the
cable never gets damp or wet while
the appliance is in use.
In order to avoid the danger of fire
and/or injuries:
• Never leave the appliance unattended
whilst in use.
•Caution! Keep children away from the
connecting cable and the appliance.
Children frequently underestimate
the danger from electrical appliances.
Ensure a safe location for the
appliance.
• Ensure that the power plug is quickly
reachable in case of danger, and also
that there is no danger of tripping
over the cable.
• In order to avoid injuries, make sure
that all the component parts are pro-
perly connected and installed.
• Ensure that the lid is properly secured
before switching on the appliance.
• Never use the appliance with an emp-
ty mixing unit.
• Never remove the lid while the appli-
ance is in use.
•Danger of injury! The cutting blade is
very sharp. Handle it with extreme
caution.
• Do not touch any rotating parts.
• Turn the appliance off after use and
pull out the power plug. Only when
the motor has come to a complete
stop may the appliance be disassem-
bled.
• Never use the appliance:
- if individual components, the con-
necting cable or the power plug are
damaged,
- in case of malfunctioning of the
appliance, or if it has been otherwise
damaged or has fallen down.
• Give the appliance for examination
and/or repair only to an authorized
service outlet.
KH 526
KH525_IB_UK 06.07.2006 10:16 Uhr Seite 5

- 6 -
KH 526
• The use of attachments and accesso-
ries that are not recommended or
sold by the manufacturer can cause fi-
re, electric shocks and/or injuries.
A safe approach:
• In case of danger, immediately pull
out the power plug from the power
point.
• Never use the appliance for purposes
other than those for which it was de-
signed.
• Always stay attentive! Always pay at-
tention to what you are doing and act
rationally. Never use the appliance
when you are distracted or don’t feel
well.
• Make sure that the appliance is cor-
rectly and completely assembled befo-
re you use it.
• The appliance may be used only after
it has been assembled as per the in-
structions, and when the cover is firm-
ly fitted on and closed.
• Each time you have finished using the
appliance, make sure that the switch
is in the “Off” position.
• Remove the detachable parts only
when the motor has come completely
to rest.
• Detach the power plug and cable
from the appliance when it is not in
use, when you detach parts or before
cleaning the appliance.
• Do not use the appliance in the open.
• Allow hot liquids to cool to a luke-
warm temperature (approx. 30-40°C)
before you pour them into the mixing
unit. You thus avoid the risk of burns.
Operation
Installing the mixing unit
Make sure that the appliance is
switched off (Switch in the “Off”
position).
Place the mixing unit on the mounted
motor unit and press it down till it is
securely engaged.
Food processing
Fill the mixing unit with the food-
stuffs, which are to be processed.
Place the cover on the mixing unit
and secure it firmly. In order to lock
the measuring cup, insert it into the
opening in the cover and twist it
clockwise till it locks.
Turn on the motor.
Note: This appliance works only when
the mixing unit is attached to the
motor unit.
Selecting the suitable speed level.
• Level 1-3
for light usage with liquids
• Level 3-5
for a firmer consistency – for the
mixing of liquids and solid foods.
• Moment Level
for use in short, powerful bursts.
(The switch does not stay in the
“Ice Crush” position. Hold the switch
down in the “Ice Crush” position or
turn it repeatedly to the “Ice Crush”
position.)
KH525_IB_UK 06.07.2006 10:16 Uhr Seite 6
Table des matières
Autres manuels Bifinett Mixer