BEP Marine CZone Contact 6 PLUS Mode d’emploi

Contact 6 PLUS
User & Installation Manual
V1.0

EN / CZone® Contact 6 PLUS User & Installation Manual
2
Copyright
This document is copyright 2018 under the Creative Commons agreement. Rights are granted to research and
reproduce elements of this document for non-commercial purposes on the condition that BEP Marine is credited as the
source. Electronic re-distribution of the document in any format is restricted, to maintain quality and version control.
Important
BEP Marine strives to ensure all information is correct at the time of printing. However, the company reserves the right
to change without notice any features and specifications of either its products or associated documentation.
Translations: In the event that there is a difference between a translation of this manual and the English version, the
English version should be considered the official version.
It is the owner’s sole responsibility to install and operate the device in a manner that will not cause accidents, personal
injury or property damage.
Use of This Manual
Copyright © 2018 BEP Marine LTD. All rights reserved.Reproduction, transfer, distribution or storage of part or all of
the contents in this document in any form without the prior written permission of BEP Marine is prohibited.This manual
serves as a guideline for the safe and effective operation, maintenance and possible correction of minor malfunctions
of the Contact 6 PLUS.

3
EN / CZone® Contact 6 PLUS User & Installation Manual
TABLE OF CONTENTS
1OVERVIEW 4
Description 4
Parts Included 4
Features 4
Hardware Overview 5
2DESIGN 7
3INSTALLATION 7
Things You Need 7
Environment 7
Mounting 8
Connections 9
Inserting Fuses 10
Mechanical Bypass 10
Network Configuration 11
Fit the Cover 12
Initial Power Up 12
System Diagram Examples 13
4ORDERING INFORMATION 14
5SPECIFICATIONS 15
Technical Specifications 15
Dimensions 16
6COMPLIANCE 17

EN / CZone® Contact 6 PLUS User & Installation Manual
4
1 OVERVIEW
DESCRIPTION
The Contact 6 PLUS is a 6-channel output module utilizing CZone’s proven solid state switching technology. Designed
to be installed with a NMEA2000 Network or as a standalone system with a CZone Smart Harness and Waterproof
Keypad. When installed with a CZone Waterproof Keypad the Contact 6 PLUS will work out of the box with a pre-
installed factory configuration. To install the Contact 6 PLUS with other CZone modules, or to configure advanced
functionality like timers and single button dimming you will need to use the CZone Configuration Tool which is available
for download at www.downloads.czone.net.
PARTS INCLUDED
1. Contact 6 PLUS interface
2. Cable connector
3. Cable gland
4. Front cover
FEATURES
• Entry level digital switching module for Marine and RV applications
• 6 x 15A output channels
• Plug-and-play out-of-the box functionality
• PWM circuit dimming and control on all channels
• Stand-alone or network with other CZone products
• Compatible with CZone integrated Multi-Function Displays (MFD’s)
• Uses proven CZone technology
• Full mechanical fuse protection with channel bypass on all circuits
• Blown fuse detection and system warnings
• Status LED’s with fault codes for all channels
• IPx5 ingress protection
• NMEA2000 compliant
1
2
3
4

5
EN / CZone® Contact 6 PLUS User & Installation Manual
HARDWARE OVERVIEW
1. Channel Status LED Indicators
2. Network Status LED Indicator
3. Mounting Holes
4. Power Supply M6 Stud
5. Output Connector
6. ATC Fuse Sockets
7. Dipswitch
8. Network / NMEA2000 Micro C Connector
9. Cable Gland
6
3
4
5
7
8
9
2
1

EN / CZone® Contact 6 PLUS User & Installation Manual
6
Channel Status LED Indicators
Colour
Description
Extinguished
Channel Off
Green Solid On
Channel On
1 Green Flash
Module Not Configured
2 Green Flash
Configuration Conflict
3 Green Flash
DIP Switch Conflict
4 Green Flash
Memory Failure
5 Green Flash
No Modules Detected
7 Green Flash
Fuse Blown
9 Green Flash
Missing Commander
Network Status LED Indicator
Colour
Description
Extinguished
Network Power Disconnected
Green
Network Power Connected
Red Flash
Network Traffic

7
EN / CZone® Contact 6 PLUS User & Installation Manual
2 DESIGN
• Make a list of all outputs to be wired to the Contact 6 PLUS and assign each of them to one of the 6 channels.
• Ensure all cables are appropriately rated for each assigned load.
• Output connector accepts cable gauges 24AWG – 8AWG (0.5 - 6mm).
• Ensure power supply cable to the Contact 6 PLUS is appropriately rated for the maximum continuous current
of all loads and is fused appropriately to protect the cable.
• Ensure continuous current draw of each connected load does not exceed maximum channel rating of 15A.
• Ensure the maximum continuous current of all loads does not exceed the 60A total module current.
• Install the appropriately rated fuses for each channel.
• Decide if you will add the Contact 6 PLUS to a NMEA2000 Network or install as a standalone system with the
CZone Smart Harness.
• Loads exceeding 15A will require paralleling 2 channels together or an external relay.
3 INSTALLATION
THINGS YOU NEED
• Electrical tools
• Wiring and fuses
• Contact 6 PLUS module
• CZone Waterproof Keypad (if required)
• CZone Smart Harness or NMEA2000 network cables
• 4 x 8G or 10G (4mm or 5mm) self-tapping screws or bolts for mounting the Contact 6 PLUS
ENVIRONMENT
Obey the following stipulations during installation:
• Ensure the Contact 6 PLUS is located in an easily accessible location and indicator LED’s are visible.
• Ensure there is enough clearance above the Contact 6 PLUS to allow the cover to be removed.
• Ensure there is at least 10mm clearance around the sides and top of the Contact 6 PLUS.
• Ensure the Contact 6 PLUS is mounted on a vertical flat surface.
• Ensure there is sufficient space for the wires to exit the product.

EN / CZone® Contact 6 PLUS User & Installation Manual
8
MOUNTING
1. Mount the Contact 6 PLUS on a vertical surface with the cables exiting downwards.
2. Allow enough space below cable grommet for wiring bend radius.
o Note - Cable radius determined by wiring manufacturer.
3. Fasten the Contact 6 PLUS by using 4 x 8G or 10G (4mm or 5mm) self-tapping screws or bolts (not supplied).
IMPORTANT - The Contact 6 PLUS must be mounted within 30 degrees from the vertical position to ensure
water correctly runs away from the product if mounted in a location where water can contact the product.

9
EN / CZone® Contact 6 PLUS User & Installation Manual
CONNECTIONS
The Contact 6 PLUS has a convenient output connector that requires no crimping tools and accepts cables from 24AWG
to 8AWG (0.5 - 6mm). The unit has no power key and will turn on when power is applied to the network. The module
will continue to draw power even when it is not in operation. It is recommended that a battery isolator switch is installed
for when the system is not in use.
1. Feed output wires through cable grommet
2. Strip and insert each wire into the connector ensuring the correctly rated wire is used for each load and tighten
screws to 4.43 in/lbs (0.5NM).
3. Insert plug firmly into module and tighten 2x retaining screws.
4. Connect CZone Smart Harness to network port. If not using the CZone Smart Harness, connect a NMEA2000
drop cable from the NMEA2000 backbone (do not power up network yet).
5. Connect the appropriate size power supply cable to the M6 positive stud and tighten to 35 in/lbs (4NM), ensuring
washers are installed as per diagram.
IMPORTANT - The positive cable must be sufficient size to carry the maximum current of all loads connected
to the Contact 6 PLUS. It is recommended to have a fuse/circuit breaker rated to protect the cable.
1
4
3
2
5

EN / CZone® Contact 6 PLUS User & Installation Manual
10
INSERTING FUSES
The Contact 6 PLUS provides ignition protected circuit protection for each individual channel via standard ATC fuses
(not supplied). Appropriately rated fuses should be selected and installed for each channel to protect the load and the
wiring for each circuit.
Fuses In Normal Operation
1. Select the appropriate fuse rating for each individual circuit.
2. Insert the correctly rated fuses into the NORMAL (bottom) position of all circuits.
3. The ATC fuse should be rated to protect the connected load and the wiring from the Contact 6 PLUS to the
load and also the ground wire.
MECHANICAL BYPASS
The Contact 6 PLUS includes a mechanical bypass feature for redundancy purposes. Moving any fuse to the BYPASS
(top) position will supply constant battery power to that output. See below diagram showing circuit #3 in the BYPASS
position.
Fuse in Bypass Position
WARNING – Ensure area is free of explosive gasses before removing/replacing fuses or placing fuses in the
bypass position as sparks may occur.
Table des matières
Manuels Unité de contrôle populaires d'autres marques

Festo
Festo Compact Performance CP-FB6-E Manuel de la liste des pièces

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuel utilisateur

JS Automation
JS Automation MPC3034A Manuel utilisateur

JAUDT
JAUDT SW GII 6406 Series Guide rapide

Spektrum
Spektrum Air Module System Manuel utilisateur

BOC Edwards
BOC Edwards Q Series Manuel utilisateur