Alvarado IntraQ-X Manuel utilisateur

PUD4253R3-0
Alvarado Manufacturing Company, Inc.
12660 Colony Street, Chino, CA 91710
Telephone: (909) 591-8431
Fax: (909) 628-1403
www.alvaradomfg.com
IntraQ-X Installation Guide
PUD4253R3-0 Version 2.0

IntraQ-X Installtion Guide Version 2.0IntraQ-X Installtion Guide Version 2.0
Contents
Document Overview. .................................................................................................................................................... 3
Support. .................................................................................................................................................................... 3
Mounting Hardware................................................................................................................................................... 3
Setting Up..................................................................................................................................................................... 4
Power Requirements. ............................................................................................................................................... 4
Door Lock/Strike Wiring. ........................................................................................................................................... 4
Strike Powered by IntraQ-X. ..................................................................................................................................... 5
Strike Powered Externally. ........................................................................................................................................ 6
Normally Open.................................................................................................................................................... 6
Normally Closed. ................................................................................................................................................ 7
External 12V Power. ................................................................................................................................................. 8
Mounting the Device..................................................................................................................................................... 9
Mounting Holes. ........................................................................................................................................................ 9
Mounting Process. ...................................................................................................................................................11
Test Relay................................................................................................................................................................ 13
Attach Case. ........................................................................................................................................................... 14
Maintenance............................................................................................................................................................... 16
Troubleshooting.......................................................................................................................................................... 17
Device doesn’t power on......................................................................................................................................... 17
Activating the relay does not unlock the door.. ....................................................................................................... 18
Revision History.......................................................................................................................................................... 19

IntraQ-X Installtion Guide Version 2.0IntraQ-X Installtion Guide Version 2.0
This guide provides instructions for installing an Alvarado IntraQ-X suite scanner. It is meant to be used by the
personnel who will install the unit. Upon completing the steps in the guide, the device will be ready for nal
conguration by Box Ofce (or other relevant) personnel.
Some notes about the scope of this document:
• Alvarado does not provide mounting hardware. The venue is expected to select appropriate mounting
hardware. The IntraQ-X unit weighs about 5 pounds.
• This guide assumes that all applicable external hardware (like power supplies, door strikes, and POE+
switches for example) is already installed and ready for use.
• Device conguration occurs after installation and is not covered by this guide.
• This guide assumes that power over Ethernet cabling is in place and ready for use. See the Power
Requirements section on page 4.
Alvarado does not provide mounting hardware with IntraQ-X units. It is the responsibility of the venue to determine
the appropriate mounting hardware to use for each device.
Contact Alvarado’s Entertainment Support department for assistance.
Phone: 909-591-8431
Email: [email protected]
Document Overview
Mounting Hardware
Support

IntraQ-X Installtion Guide Version 2.0IntraQ-X Installtion Guide Version 2.0
Setting Up
Power Requirements
Door Lock/Strike Wiring
• POE+ is only required if the IntraQ-X devices will supply power to door strikes. However, Alvarado
recommends POE+ for all installations, even if the IntraQ-X devices will not power the door strikes.
• Alvarado recommends that the POE+ switch power settings are set to MAX power setting and not Auto-
Negotiate.
• An IntraQ-X can provide a maximum of 12V DC at 600 milliamps to the door strike.
The IntraQ-X has a 12V DC relay on the board that can power and activate a door strike. The relay on the board
can be set to normally open or normally closed in the device’s conguration. If the door strike is being powered
externally, then the board must connect to an external 12V DC relay. Refer to the diagrams below.
IMPORTANT The items in this section must be addressed before you attempt to install the IntraQ-X
device.
Relay terminal block

IntraQ-X Installtion Guide Version 2.0IntraQ-X Installtion Guide Version 2.0
Strike Powered by IntraQ-X
A setting in the application conguration les determines whether the relay on the board is normally open or
normally closed. The relay is set to normally open by default.
NOTE Door strikes must be a maximum of 12VDC 600 mA for the IntraQ-X to supply power.

IntraQ-X Installtion Guide Version 2.0IntraQ-X Installtion Guide Version 2.0
Strike Powered Externally
An external 12V relay is required if an external power supply will provide power to the door strike (not supplied by
Alvarado).
The relay on board set to normally open in the software conguration.
Normally Open

IntraQ-X Installtion Guide Version 2.0IntraQ-X Installtion Guide Version 2.0
Normally Closed
The relay on board set to normally closed in software conguration

IntraQ-X Installtion Guide Version 2.0IntraQ-X Installtion Guide Version 2.0
External 12V Power
IntraQ-X devices with 10-2060D boards (supplied by Alvarado) receive 12V DC power from connectors instead of
from the POE. Door strike wiring is identical to the illustrations above.

IntraQ-X Installtion Guide Version 2.0IntraQ-X Installtion Guide Version 2.0
(Shown with the printer box open from the right-hand side.)
Mounting the Device
Mounting Holes
The drawing below displays the IntraQ-X’s backplate dimensions.
Alvarado does not provide mounting hardware with IntraQ-X devices. The venue is expected to provide size #8 or
M4 mounting hardware. The IntraQ-X unit weighs about 5 pounds.
6.46
(164.1)
1.26
(32.0)
5.70
(144.7) 0
0
8.43
(214.1)
5.87
(149.2
)
1.44
(36.5)

IntraQ-X Installtion Guide Version 2.0IntraQ-X Installtion Guide Version 2.0
Table des matières
Manuels Terminal tactile populaires d'autres marques

Wincor Nixdorf
Wincor Nixdorf iPOS plus Advanced Manuel utilisateur

Ingenico
Ingenico AXIUM EX4000 Manuel utilisateur

Heisei Electronics
Heisei Electronics Q-POS 815 Manuel utilisateur

Amano
Amano MTX-15 Manuel utilisateur

FLOWBIRD
FLOWBIRD CWT Compact Touch Manuel utilisateur

Demco
Demco SP7 Manuel utilisateur