Yeeka 1507 IoT Lock Manuel utilisateur

www.
yeekaco
.com
1
1507 IoT Lock
Operation Manual V1.0.0
Wenzhou Yeeka Lock Technology Co.,Ltd
Address:No.49,Fuyang North Road, Sanxi Industrial Park .Ouhai district, Wenzhou,China

www.
yeekaco
.com
2
Contents
1. Preface ............................................................................................................4
1.1 Read and keep instructions ............................................................................4
1.2 Support and Services......................................................................................4
1.2.1 Warranty ..........................................................................................................4
2. Overview .........................................................................................................5
2.1 Usage ..............................................................................................................5
2.1.1 Features...........................................................................................................5
2.2 System Architecture Diagram .........................................................................6
2.3 Management Platform.....................................................................................7
3. IoT Lock instructions .......................................................................................8
3.1 Product appearance........................................................................................8
3.2 Installation Diagram ........................................................................................9
3.3 Wiring Diagram .............................................................................................10
3.4 Functional schematic diagram ......................................................................10
3.4.1 Password functional schematic diagram .....................................................10
3.4.2 Card read functional schematic diagram.....................................................11
3.4.3 Finger print functional schematic diagram...................................................11
3.4.4 Lock back functional schematic diagram.....................................................12
3.4.5 Head functional schematic diagram ............................................................12
3.5 Operation Instructions .................................................................................13
3.5.1 Access way of Mechanical key:...................................................................13
3.5.2 Access way of DO Remote Control: ............................................................13

www.
yeekaco
.com
3
3.5.3 Access way of RS485 Remote Control: ....................................................13
3.5.4 Access way of password:........................................................................13
3.5.5 Access way of card read:...........................................................................13
3.5.6 Access way of QR code:............................................................................13
3.5.7 Access way of finger print: .........................................................................14
3.6 Programming instructions..........................................................................14
3.6.1 Password programming .............................................................................14
3.6.2 Card read programming.............................................................................15
3.6.2.1 Card read programming(when the handle has keypad).............................15
3.6.2.2 Card read programming(when the handle has no keypad) .......................15
3.6.3 Fingerprint setting ......................................................................................15
4. Controller instructions................................................................................16
4.1 Functional diagram....................................................................................16
4.2 Wiring diagram ..........................................................................................16
4.3 Operating instructions ...............................................................................17
4.3.1 Controller configuration..............................................................................17
4.3.2 Platform operation......................................................................................17

www.
yeekaco
.com
4
1. Preface
Thanks for choosing 1507 IoT lock. On behalf of Yeeka team, we thank you for your
purchase. The instructions in this manual provide technicians with information on the
installation, operation, and setting of the 1507 IoT lock.Please supervise inexperienced
users to ensure pleasant and safe operation.
1.1 Read and keep instructions
Please read and understand this manual before using the 1507 IoT lock.Retain all
instructions for future reference and provide it to subsequent users of the product.And
follow all instructions to avoid any hazards caused by improper operation.
The 1507 IoT lock is only applicable for those who have fully read and understood the
contents of this manual to use.Make sure everyone who use the 1507 IoT lock have
read these instructions and followed them. For product damage caused by incorrect
operation, the warranty service will be invalid.
1.2 Support and Services
Maintain original purchase records to claim warranty services.Service options depend
on the status of the IoT lock warranty.Please attach the serial name of the product when
contacting yeeka for product support.All 1507 IoT lock have a serial name, which is a
unique identifier used to track the history of manufacturing, sales, and maintenance.
The serial name is located on the back of the device in the following format: SN:
167777777.
The service provider of Yeeka products also provides technical support and services.If
yeeka or a certified service provider provides extended warranty or other services,
separate quotation terms may be used. For products purchased from certified service
providers, please contact the original service provider for assistance before contacting
yeeka.For any requests for support or services, including product information, technical
assistance or explanatory assistance,please contact Yeeka or certified service provider.
1.2.1 Warranty
This product is provided with warranty service. Yeeka provides warranty for all Yeeka
brand hardware.Unless otherwise expressly provided, the terms of service (including
warranty) constitute the entire agreement between you and yeeka,covering after-sales
services and any products you purchase from yeeka, and supersede all prior or
contemporaneous communications, proposals and agreements between you and yeeka,
whether electronic, oral or handwritten. Please read the warranty instructions for more
details of yeeka warranty service in your area.

www.
yeekaco
.com
5
2. Overview
2.1 Usage
The 1507 series intelligent lock is suitable for data center, which can solve the problem
of authority management and data asset security.In addition, the intelligent lock can be
controlled remotely and the temperature and humidity of cabinet can be remotely
collected.
The access ways can be obtained through mechanical key, password, card, fingerprint,
Bluetooth, remote management platform and mobile APP.
It can be used on a stand-alone basis, independently on a network, or connected to a
carrier's network.
2.1.1 Features
1.Cabinet intelligent locks can implement functions such as diversified access ways,
user authority management, query of lock operation records, and intelligent
management of lock tasks.
2.Adopt modular design, no special control unit and readers, integrated with password
button, card readers,Bluetooth communication modules, fingerprint identification
modules, RS485 communication modules.
3.Driven by high reliability motor and adopted high stability hardware design to
guarantee the stability and reliability of the product.
4.High versatility of the cabinet.The lock is suitable for APC, Emerson, Vertiv, Eaton,
Toten, Panduit, CPI and etc.
5.The electronic lock can connect various intelligent PDU or control unit for remote
communication and control.
6.The appearance of the product is simple and elegant, easy to use and convenient to
install and maintain.

www.
yeekaco
.com
6
Access Unit
Management Platform
Switch
Access Unit
Access Unit Wireless
Wireless electronic lock
Wired electronic lock
Sensor
2.2 System Architecture Diagram

www.
yeekaco
.com
7
Task Management
⚫ Task dispatching
Records Query
⚫Operation record query
⚫Alarm record query
Data Analysis
⚫Data analysis of unlocking
⚫Data analysis of temperature
and humidity
⚫Data analysis of other sensors
2.3 Management Platform
Features
Monitor Center
⚫Equipment information overview
⚫Display lock status by color change
⚫Real-time alarm alerts
⚫Powerful search query function to
get rapid positioning of the lock
Equipment Management
⚫Set the lock area
⚫Manage lock and control unit
User Management
⚫User authority management
⚫User department management

www.
yeekaco
.com
8
3. IoT Lock instructions
3.1 Product appearance

www.
yeekaco
.com
9
Screw
Panel
Mounting
bracket
Cam
Locating
plate
Lock
3.2 Installation Diagram

www.
yeekaco
.com
10
3.3 Wiring Diagram
Pin No
Color
Signal Definition
Wire Gauge
1
Red
12V +
UL2464/26AWG
2
Black
GND
3
Yellow
485+
4
Green
485-
5
White
DO+
6
Blue
DO-
7
Orange
lock status
8
Brown
lock status
3.4 Functional schematic diagram
3.4.1 Password functional schematic diagram
Table des matières