Xinje XMP2-32 series Manuel utilisateur

XINJE
XMP2-32 series
Integral industrial controller
Operating manual
Xinje Electronic Co.,Ltd

Catalog
1. XMP2-32 introduction..................................................................................................................4
1-1 Performance and characteristic...........................................................................................4
1-2 Specs...................................................................................................................................4
1-2-1 General specs...........................................................................................................4
1-2-2 HMI specs................................................................................................................5
1-2-3 PLC specs................................................................................................................5
1-2-4 Product type.............................................................................................................6
1-2-5 Name rule ................................................................................................................6
1-3 Part name............................................................................................................................7
1-3-1 LED display.............................................................................................................8
1-3-2 Download port.........................................................................................................8
1-3-3 Com port..................................................................................................................9
1-3-4 Port A and B ............................................................................................................9
1-4 Outline dimension...............................................................................................................9
2. In-out specs and exterior layout..................................................................................................10
2-1 Input specs and layout ......................................................................................................10
2-2 Output specs and layout....................................................................................................11
3. PLC function and using...............................................................................................................13
3-1 PLC instruction.................................................................................................................13
3-2 Soft component range.......................................................................................................14
3-3 Build a project...................................................................................................................16
3-4 Communication function..................................................................................................18
3-4-1 Com port................................................................................................................18
3-4-2 Communication parameters...................................................................................18
3-4-3 Communication mode ...........................................................................................20
4. HMI function and using..............................................................................................................21
4-1 HMI function....................................................................................................................21
4-2 Build a project...................................................................................................................23
5. The extension ability...................................................................................................................25
5-1 Summarization..................................................................................................................25
5-2. Extend MA model............................................................................................................26


0B1. XMP2-32 introduction
1-1 Performance and characteristic
XMP2-32R-E ( relay output type ) and XMP2-32T-E ( transistor output type ) are integrated with
HMI ( MP series ) and PLC ( XC2 series ) perfectly. They can totally instead of HMI and PLC in
control system with the premiss of meeting the control requests. Small profile can save space and
improve the maintenance convenience.
◆XMP2-32=MP760-T + XC2-32
◆Integrated with logical control, analog quantity in-out, HMI ( human machine interface )
On-off input: 16 points
On-off output: 16 points
uHMI screen: editing simply and directly, rich function, touchable display area
◆ LCD display: 480×234 pixel, 7 inch screen, LCD life can reach 0.5 million hours
◆ 26 function keys, function setting freely, sensitive and precise key-press
◆ Support high speed count, high speed pulse, external interrupt
◆ Mix function designed download port: the same cable for downloading HMI and PLC
program
◆ Waterproof level is IP20
◆ Close construction, save the space of electric control cabinet
◆ Simple, modern and decent appearance
1-2 Specs
1-2-1 General specs
Input voltage AC220V or DC24V
Power Less than 10W (TYP2.0W)
Instant power off
allowance
Less than 20ms
Voltage endurance AC1000V-10mA 1minute between signal and ground
Insulated impedance
DC500V about 10MΩ ( between signal and ground )
Operating
temperature
0~50℃
Conservation
temperature
–10~60℃
Environment
temperature
20~85% (no dew)
Oscillation
endurance
10~25Hz ( X,Y, Z direction for 30 minutes 2G )

Anti-jamming Voltage noise: 1000Vp-p
Air condition No causticity gas
Protect construction
According to IP20
1-2-2 HMI specs
1-2-3 PLC specs
Specs
Item XMP2-32
Programexecuting format Loop scan format, time scan format
Programformat Instruction, C language and ladder chart
Processing speed 0.5us
Power cut retaining Use Flash ROM and Li battery
User program’s capacity 128KB
I/O points Input 16 points, output 16 points
Interior coil’s points (M) 8767
Points 640
Timer
(T)Specs
100mS timer:Set time 0.1~3276.7 seconds
10mS timer:Set time 0.01~327.67 seconds
1mS timer:Set time 0.001~32.767 seconds
Points 640
Counter
(C)Specs 16 bits counter:set value K0~32767
32 bits counter:set value -2147483648~2147483647
Data Register(D)2612 words
Flash ROM Register(FD)
512 words
Type TFT 256-colour LCD
Screen dimension
7 inch
Use life Over 50000 hours, 25℃, 24 hours operating
Display area 480*234
Contrast Unable to change
Character setting Chinese, English, Japanese, Korean, etc.
Character size Free size and font
Characteristic
Touch mode Digital mode touch
Picture 8MB Flash ROM
Register Data 4KB SRAM
Communicate
port RS-232/RS-485
Interface
Download port RS-232

High speed processing
function
High speed count、pulse output、external interrupt
Setting of time scan space 0~99mS
Password protection 6 bits ASCII
Self diagnose function Power on self-diagnose、Monitor timer、grammar check
1-2-4 Product type
XMP-32 series
Relay output Transistor output
XMP2-32R-E XMP2-32T-E
XMP2-32R-C XMP3-32T-C
NOTE:
-E means the power supply is AC220V
-C means the power supply is DC24V
1-2-5 Name rule
1 2 3 4
1: series name XMP
2: PLC type 2: XC2 series
3: I/O points 32: input 16/output 16 points
4: output type R: relay output
T: transistor output

1-3 Part name
Display and touch
area
Number key
Function key
Power point
Product label
Input pointOutput point
Com
port
Download
port
USB、CJ45 port

1-3-1 LED display
PWR: Power supply
RUN: program running
STOP: program stop
1-3-2 Download port
nThe port is RS-232 standard and double function designed, is able to download PLC program
and HMI program.
Pin2 RXD
Pin3 TXD
Pin5 GND
Pin7 RTS
nUsed as RS-485 com port: for HMI connecting with slave device
Cable connection figure:
Attention:
(1) Do not cut the power when downloading, or you have to download again
(2) The cable of downloading HMI program is the same as the downloading PLC program
(3) Do not download when XCPPro and Touchwin software are both running
(4) RS-232 download port is only used to download, do not use it in other way
Pin1
A
Pin9 B
Pin6 PRT (when HMI connecting with slave device, short pin
5&6 )
Pin8 DOWNLOAD ( short pin 5&8 to forced-download HMI
program )

1-3-3 Com port
The port is RS-232 standard, is used to connect PC and HMI.
Pin2 RXD
Pin3 TXD
Pin5 GND
1-3-4 PortAand B
The port is RS-485 standard, is used to connect meter, inverter, extension model, etc.
Attention:
A, B port and RS-232 com port are the same port, can not be used at the same time.
1-4 Outline dimension
Outline dimension ( mm ):

Installate dimension ( mm ):
1
B2. In-out specs and exterior layout
2-1 Input specs and layout
Input specs:
Input connection figure:
Input signal voltage DC24V±10%
Input signal current 7mA/DC24V
Input ON current Above 4.5mA
Input OFF current Below 1.5mA
Input response time About 10ms
Input signal format Point input or NPN
collector open transistor
Circuit insulation Photo-electricity coupling
insulation
Input action display LED is ON when input ON
Table des matières
Autres manuels Xinje Contrôleurs