Xilinx Alveo U200 Manuel utilisateur

Revision History
The following table shows the revision history for this document.
Section Revision Summary
06/03/2020 Version 1.5
Chapter 1: Introduction Updated the information.
Card Features Added new section.
xbutil validate Updated information about specifying -d.
12/18/2019 Version 1.4
XRT and Deployment Package Installation Procedures on
Ubuntu
Added a note about XRT installation.
Chapter 7: Troubleshooting Updated information about installing packages on RedHat
and CentOS.
Known Issues Added a known issue.
10/31/2019 Version 2019.2
General Updated to the Vitis™ unified software platform throughout.
Updated outputs throughout document.
Qualified Servers Provided the web link to the qualified servers.
Chapter 4: Installing the Deployment Software Replaced xbutil command with the new xbmgmt
command for card flashing. Updated output logs.
Known Issues Added a known issue.
XRT and Deployment Platform Installation Procedures on
RedHat and CentOS Replaced xbutil command with the new xbmgmt
command for card flashing. Updated output logs.
XRT and Deployment Package Installation Procedures on
Ubuntu
Running xbmgmt flash --scan Replaced xbutil command with the new xbmgmt
command when scanning card. Updated output logs.
Appendix A: Changing XRT and Target Platform Versions Replaced xbutil command with the new xbmgmt
command for card flashing. Updated output logs.
Appendix C: Reverting the Card to Factory Image Added new appendix.
07/23/2019 Version 2019.1
Upgrade from 2018.x to 2019.1 in RedHat and CentOS Corrected answer record links
Upgrade from 2018.2 to 2018.3 in RedHat and CentOS
Upgrade from 2018.2 to 2018.3 in Ubuntu
Downgrade from 2018.3 to 2018.2 in Ubuntu
Upgrade from 2018.x to 2019.1 in Ubuntu
Downgrade from 2018.3 to 2018.2 in RedHat and CentOS
Chapter 1: Introduction
06/27/2019 Version 2019.1
Qualified Servers Updated server requirements.
Revision History
UG1301 (v1.5) June 3, 2020 www.xilinx.com
Getting Started with Alveo Accelerator Cards 2
Send Feedback

Section Revision Summary
06/24/2019 Version 2019.1
General Added support for Alveo U280 production card.
Appendix A: Changing XRT and Target Platform Versions Updated upgrade and downgrade steps.
06/05/2019 Version 2019.1
General Updated outputs throughout document.
Qualified Servers Updated table of validated servers.
Card Interfaces and Details Added information on status LEDs.
Installing the Card Added image of an installed Alveo card.
Chapter 4: Installing the Deployment Software Updated installation, upgrade, and downgrade flows for
2019.1 release.
Chapter 6: Next Steps Added information on additional development resources.
Chapter 7: Troubleshooting Updated troubleshooting and known issues.
02/12/2019 Version 1.3
General Added support for Alveo U280 ES card.
Modifying the Installation on RedHat and CentOS, Modifying
the Installation on Ubuntu
Updated instructions on upgrading and downgrading XRT
and the deployment shell.
Appendix D: Generating the xbmgmt flash --update
Command
Updated instructions.
01/23/2019 Version 1.2
XRT and Deployment Platform Installation Procedures on
RedHat and CentOS, XRT and Deployment Package
Installation Procedures on Ubuntu
Updated instructions on running xbutil flash.
Appendix D: Generating the xbmgmt flash --update
Command
Added new information on how to generate the options
needed to run xbutil flash.
12/21/2018 Version 1.1
Minimum System Requirements Updated system requirements.
XRT and Deployment Platform Installation Procedures on
RedHat and CentOS
Updated installation flow.
Modifying the Installation on RedHat and CentOS Added new information on upgrading and downgrading
deployment software.
Modifying the Installation on Ubuntu Added new information on upgrading and downgrading
deployment software.
Known Issues Updated known issues.
Appendix B: Creating a Vault Repository for CentOS Added new appendix.
10/02/2018 Version 1.0
Initial Xilinx release. N/A
Revision History
UG1301 (v1.5) June 3, 2020 www.xilinx.com
Getting Started with Alveo Accelerator Cards 3
Send Feedback

Table of Contents
Revision History...............................................................................................................2
Chapter 1: Introduction.............................................................................................. 6
Card Features...............................................................................................................................6
Minimum System Requirements...............................................................................................7
Qualified Servers......................................................................................................................... 8
Chapter 2: Unpacking...................................................................................................9
Accelerator Card Overview.........................................................................................................9
Chapter 3: Card Installation Procedures......................................................... 12
Safety Instructions.................................................................................................................... 12
Before You Begin.......................................................................................................................14
Installing the Card.....................................................................................................................15
Chapter 4: Installing the Deployment Software......................................... 20
XRT and Deployment Platform Installation Procedures on RedHat and CentOS............. 20
XRT and Deployment Package Installation Procedures on Ubuntu................................... 24
Chapter 5: Card Bring-Up and Validation........................................................27
Running lspci............................................................................................................................. 27
Running xbmgmt flash --scan................................................................................................. 28
xbutil validate............................................................................................................................ 29
Chapter 6: Next Steps.................................................................................................31
Chapter 7: Troubleshooting.................................................................................... 32
Known Issues.............................................................................................................................33
Appendix A: Changing XRT and Target Platform Versions....................35
RedHat and CentOS.................................................................................................................. 35
Ubuntu........................................................................................................................................41
Appendix B: Creating a Vault Repository for CentOS...............................48
UG1301 (v1.5) June 3, 2020 www.xilinx.com
Getting Started with Alveo Accelerator Cards 4
Send Feedback

Appendix C: Reverting the Card to Factory Image.................................... 50
Appendix D: Generating the xbmgmt flash --update Command...... 51
Appendix E: Additional Resources and Legal Notices..............................53
Xilinx Resources.........................................................................................................................53
Documentation Navigator and Design Hubs.........................................................................53
References..................................................................................................................................54
Please Read: Important Legal Notices................................................................................... 54
UG1301 (v1.5) June 3, 2020 www.xilinx.com
Getting Started with Alveo Accelerator Cards 5
Send Feedback

Chapter 1
Introduction
This document provides hardware and soware installaon procedures for the U200, U250, and
U280 Alveo™ Data Center accelerator cards and applies to Vis™ release 2019.2 and later. If you
are using an earlier SDAccel™ release, follow the instrucons in v1.3 of Geng Started with Alveo
Data Center Accelerator Cards (UG1301).
The Xilinx® Alveo™ U200/U250/U280 Data Center accelerator cards are peripheral component
interconnect express (PCIe®) Gen3 x16 compliant cards featuring the Xilinx Virtex® UltraScale+™
technology. These cards accelerate compute-intensive applicaons such as machine learning,
data analycs, video processing, and more. The Alveo U200/U250/U280 Data Center
accelerator cards are available in passive and acve cooling conguraons.
Dierent system conguraons are available for running, developing, and debugging applicaons
on your Alveo accelerator cards:
•Running Applicaons: To run accelerated applicaons, install an Alveo card into a system as
described in Chapter 3: Card Installaon Procedures along with the required deployment
soware to support running applicaons as described in Chapter 4: Installing the Deployment
Soware.
•Developing Applicaons: To develop FPGA accelerated applicaons, it is necessary to install
both the deployment soware and the development soware. Development soware
installaon, described in Chapter 6: Next Steps, installs both a development target plaorm
and the Vis environment. This conguraon does not have an Alveo card installed and is
used for development along with debugging in emulaon modes.
•Running, Developing, and Debugging Applicaons: By installing the Alveo card along with
both the deployment and development soware on a single machine, you can congure a
system for developing and running accelerated applicaons. With the card installed,
developers can debug applicaons in both emulaon modes and on the hardware.
Card Features
Features of the Alveo U200/U250/U280 data center accelerator cards are listed in the following
table.
Chapter 1: Introduction
UG1301 (v1.5) June 3, 2020 www.xilinx.com
Getting Started with Alveo Accelerator Cards 6
Send Feedback

Table 1: Alveo U200/U250/U280 Features
Card Component U200 U250 U280
FPGA UltraScale+
XCU200-2FSGD2104E
UltraScale+
XCU250-2LFIGD2104E
UltraScale+
XCU280-L2FSVH2892E
DDR4 64 gigabyte (GB)
4x DDR4 16 GB
32 gigabyte (GB)
2x DDR4 16 GB
2400 mega-transfers per second (MT/s), 64-bit with error correcting code (ECC) DIMM
x4/x8 unregistered dual inline memory module (UDIMM) support
HBM – – ✓
Configuration Options 1 gigabit (Gb) Quad Serial Peripheral Interface (SPI) flash memory
Micro-AB universal serial bus (USB) JTAG configuration port
PCIe 16-lane PCI Express
PCIe Integrated Endpoint block connectivity
Gen1, 2, or 3 up to x16
I2C Bus ✓✓✓
Status LEDs ✓✓✓
Power Management Power management with system management bus (SMBus) voltage, current, and
temperature monitoring
External Power Sources 65W PCIe slot functional with PCIe slot power only
150 W PCIe slot functional with 110 A max VCCINT current PCIe slot power and 6-pin PCIe
AUX power cable connected
225 W PCIe slot functional with 160 A max VCCINT current PCIe slot power and 8-pin PCIe
AUX power cable connected
Flash Memory Onboard reprogrammable flash configuration memory
UART Universal asynchronous receiver-transmitter (UART) access through the USB port
Configuration UltraScale+ device configurable over USB/JTAG and Quad SPI configuration flash memory
Minimum System Requirements
The minimum system requirements for running the Alveo™ U200/U250/U280 Data Center
accelerator cards are listed below:
Table 2: Minimum System Requirements
Component Requirement
Motherboard PCI Express® 3.0-compatible with one dual-width x16 slot.
System Power Supply 225W via PCI Express Slot connection and 8-pin PCI Express Auxiliary Power
cable.
Operating System Linux, 64-bit:
•Ubuntu 16.04, 18.04
•CentOS 7.4, 7.5, 7.6
•RHEL 7.4, 7.5, 7.6
Chapter 1: Introduction
UG1301 (v1.5) June 3, 2020 www.xilinx.com
Getting Started with Alveo Accelerator Cards 7
Send Feedback

Table 2: Minimum System Requirements (cont'd)
Component Requirement
System Memory For deployment installations, a minimum of 16 GB plus application memory
requirements is required.
For development installations, a minimum of 64 GB of device memory is
required, but 80 GB is recommended.
Internet Connection Required for downloading drivers and utilities.
Hard disk space Satisfy the minimum system requirements for your operating system.
Licensing None required for application deployment.
For the application development environment, see Vitis Unified Software
Platform Documentation: Application Acceleration Development (UG1393).
For addional specicaons and details on the acceptable environmental condions, see Alveo
U200 and U250 Data Center Accelerator Cards Data Sheet (DS962) and Alveo U280 Data Center
Accelerator Cards Data Sheet (DS963).
Qualified Servers
A list of servers on which Alveo cards are fully qualied on can be found here:
hps://www.xilinx.com/products/boards-and-kits/alveo/qualied-servers.html.
Chapter 1: Introduction
UG1301 (v1.5) June 3, 2020 www.xilinx.com
Getting Started with Alveo Accelerator Cards 8
Send Feedback

Chapter 2
Unpacking
Accelerator Card Overview
Card Interfaces and Details
Alveo™ cards are available in both passive and acve cooling conguraons; see Passive and
Acve Cooling Cards. The interfaces of each are idencal, except the fan included on acve
cooled cards. The card includes the following interfaces, and are shown in the following gure:
1. A PCI Express® card connector.
2. A PCI Express Auxiliary Power Connector. This connector is shown in Figure 4. Connector is
not compable with an ATX12V/EPS12V power source.
3. Two QSFP interfaces. Currently these interfaces are not supported by the deployment
plaorm.
4. A Micro-USB connector for maintenance purposes.
5. A fan for the acve cooled card conguraon.
WARNING! Hazardous moving parts. Keep away from fan blades.
ATTENTION! Pièces mobiles peuvent etre dangereuses. Éloignez-vous des lames du venlateur.
WARNUNG! Gefährliche bewegliche Teile. Halten sie sich von Lüerügeln fern.
Chapter 2: Unpacking
UG1301 (v1.5) June 3, 2020 www.xilinx.com
Getting Started with Alveo Accelerator Cards 9
Send Feedback

Figure 1: Alveo Card Features
Fan
(for Active configuration only)
PCIe
Connector
Micro-USB
Interface
Network
Interface
Note: On the Alveo U280 card, the Micro-USB is located on the opposite end of the card between the PCB
board and the enclosure.
Passive and Active Cooling Cards
Alveo™ cards are available in both acve and passive cooling conguraons, as shown in the
following gures. The passive cooling card is designed to be installed into a data center server,
where controlled air ow provides direct cooling. The acve cooling card is designed to be
installed into a PC environment where the air ow is uncontrolled; consequently, this
conguraon includes a heat sink and fan enclosure cover to provide appropriate cooling.
For card specicaons, dimensions, list of card features, and block diagram see Alveo U200 and
U250 Data Center Accelerator Cards Data Sheet (DS962) and Alveo U280 Data Center Accelerator
Cards Data Sheet (DS963).
Note: The U280 related specicaons in this document apply to producon U280 cards. Any dierences in
U280 ES1 card specicaons and capabilies are documented in the U280 ES1 Known Issues Xilinx
Answer 71925.
Chapter 2: Unpacking
UG1301 (v1.5) June 3, 2020 www.xilinx.com
Getting Started with Alveo Accelerator Cards 10
Send Feedback
Autres manuels pour Alveo U200
4
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Xilinx Stockage
Manuels Stockage populaires d'autres marques

Spectra Logic
Spectra Logic T-Series Spectra T50e Manuel utilisateur

Panasonic
Panasonic LKM-F931-1 Manuel utilisateur

Tabernus
Tabernus Enterprise Erase E2400 Manuel utilisateur

Rocstor
Rocstor COMMANDER 3F series Manuel utilisateur

HP
HP P9000 Manuel utilisateur

Western Digital
Western Digital Ultrastar Data60 Manuel utilisateur