WIS NETWORKS WIS-SF800P Manuel utilisateur

Quick Setup Guide
Smart PoE Switch
Models:
Version: 1.0
WIS-SF800P/WIS-SG800P/WIS-SG900P

Interface
1
Front Panel
Voltage Switch
Voltage Switch
LED Indicator
- Switch to 48V/24V/12V power output for all ports
VLAN Switch
LED Indicator
8*10/100Mbps RJ45 Ports
OFF : Switch is power off
Green
Green
Green
Green
Orange
ON : Switch is power on
OFF : NO device connected
ON : Device connected
FLASHING : Data transfering
OFF : No power output
ON : Normal PoE output
FLASHING : Power output error
12V : Switch PoE power to 12V
24V : Switch PoE power to 24V
48V : Switch PoE power to 48V
OFF: PoE power consumption < 40%
40% : PoE power consumption between 40%~80%
80% : PoE power consumption >80%
LED
PWR
LNK/ACT
PoE
PoE CONS
12V/24V/48V
COLOR DESCRIPTION

Rear Panel
- A three-way power socket for 100~240V AC power input
- At the left side of power socket, please get it properly grounding.
VLAN Switch
- By default it is disabled. All the ports is equal to each other and reachable.
- If enable the VLAN, the system works with VLAN isolation mode, that is port 2~8 CANNOT
communicate to each other, but only available to communicate with port 1 (uplink). This
makes avoid the network broadcast storm and better security.
- The switch needs to reboot after change the VLAN setting.
- Please power off the device if need to change the output power.
- If the switch work in passive PoE 12V or 24V mode, please use the uplink port to connect
to other devices.
100~240V AC
50/60Hz
AC Input
AC Input
Grounding Terminal
Grounding Terminal
ATTENTION

Network Example
2
Install the Switch
3
Instructions before installing
- Please do not put the switch near the water or in humid areas .
- Please make sure the working voltage conforms to the voltage labeled on the switch.
- Do not open the enclosure when the switch is working, even in the case of no power.
phone padDesktop Laptop
radius server
Core Switch
Wicontroller NMS
WIS- CM712AC WIS- CM712AC
WIS-R5100
Internet
PS Vita
iPad
Wired
Wireless
WIS-SF800P
48VDC PoE48VDC PoE

Install on 19’’ rack
Power Up the Switch
PM3008GSN
8-Port Gigabit PoE Switch
PM3008GSN
8-Port Gigabit PoE Switch
Bracket
Screw
1. Check the rack stability and grounding
2. Mount the two bracket in the package to the two side of the switch with screws
3. Put the switch to a proper position of the racks
4. Mount the brackets to the rack with screws, make sure the switch is tight and steady.
- Check the power source is compliant to the standard of the switch requirement. Once power up
the switch will auto initiate. All leds of Ethernet port will flash one time except PoE indicators.
- The power led will be on all the time.

Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
WARNING:
Do not use this product in location that can be submerged by water.
WARNING:
Avoid using this product during an electrical storm. There may be a
remote risk of electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements indicated
on the manufacturer’s label. Connection to a different power source than those specified may result
in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
2. There are no operator serviceable parts inside this equipment. Service should be provided only by
a qualified service technician.
3. This equipment is provided with a detachable power cord which has an integral safety ground wire
intended for connection to a grounded safety outlet.
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable
to it. Alert sign must be indicated if a restriction on use applied to the product and it must follow the CE
marking.
a. Do not substitute the power cord with one that is not the provided approved type. Never
use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the
grounding wire.
b. The equipment requires the use of the ground wire as a part of the safety certification,
modification or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation
prior to connecting the equipment.
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide
appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and
regulations.

RoHS/WEEE Compliance Statement
European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or
its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this
product should be disposed of separately from regular household waste streams. It is your responsibility
to dispose of this and other electric and electronic equipment via designated collection facilities appointed
by the government or local authorities. Correct disposal and recycling will help prevent potential negative
consequences to the environment and human health. For more detailed information about the disposal of
your old equipment, please contact your local authorities, waste disposal service, or the shop where you
purchased the product.
FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired
operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Limited Warranty
Wisnetworks warrants that the product(s) furnished hereunder (the “Product(s)”) shall be free from
defects in material and workmanship for a period of two (2) years from the date of shipment by
Wisnetworks under normal use and operation. Wisnetworks sole and exclusive obligation and liability
under the foregoing warranty shall be for Wisnetworks, at its discretion, to repair or replace any Product
that fails to conform to the above warranty during the above warranty period. The expense of removal
and reinstallation of any Product is not included in this warranty. The warranty period of any repaired or
replaced Product shall not extend beyond its original term.
Warranty Condition
The above warranty does not apply if the Product:
(a) has been modified and/or altered, or an addition made thereto, except by Wisnetworks, or our
authorized representatives, or as approved by Wisnetworks in writing;
(b) has been painted, rebranded or physically modified in any way;
(c) has been damaged due to errors or defects in cabling;
(d) has been subjected to misuse, abuse, negligence, abnormal physical, electromagnetic or electrical
stress, including lightning strikes, or accident;
(e) has been damaged or impaired as a result of using third party firmware;
(f) has no original Wisnetworks MAC/SN label, or is missing any other original Wisnetworks label(s);
(g) human reasons without according to the guide or user manual.
In addition, the above warranty shall apply only if: the product has been properly installed and used at
all times in accordance, and in all material respects, with the applicable Product documentation; all
Ethernet cabling runs use CAT5 (or above), and for outdoor installations, shielded Ethernet cabling is
used, and for indoor installations, indoor cabling requirements are followed.
Online Support
For more guide and help, please go to
www.wisnetworks.com/support/
You can contact email
We’ll reply you within one weekday.
Ce manuel convient aux modèles suivants
2
Table des matières