Wireless Devices NetPage NP-14 Series Manuel utilisateur

1
NetPage Network Wireless Paging System (POCSAG)
NP-14 Series
Operation Manual
CCW152231-001

2
INTRODUCTION
The NP-14 Network wireless paging system is a fully-programmable, single-board,
POCSAG encoder with the Hi power synthesized transmitter for every on-site paging
System applications.
The unit provides a combined alarm input and link command paging solution via
either the external computer console, ON/OFF closing contacts, RS232 port, RJ-45
Ethernet port. It is suitable for the industrial alarm and commercial site paging to
obtain a fast response to all kinds of the security problem monitoring situations.
The typical applications include the Fire, Security and Nurse Call System etc fields.
The communication to the transmitter via the RS232 port or RJ-45 port uses a
Common and simple protocol such as the SCOPE, TAP, Comp1, Comp2,….
About the transmission, the NP-14 is a single-board synthesized message transmitter
that operates in the 410-490MHz, 868MHz, 915MHz, 931MHz, frequency bands.
The NP-14 inside encoder contents, which are the capcode, speed and message
Etc, can be sent by the tone-only, numeric(4-bit), alphanumeric(7-bit) using the
POCSAG paging protocol out from either the serial port or from the Ethernet port.
The NP-14 option selection also has 8 ON/OFF contacts for the alarm paging
applications. Each input is an independent port control for the contact input status
either from the open to short or from the short to open. Once the alarm is activated,
the pre-programmed input capcode and message will be sent out immediately. All of
the programming 8 inputs paging carrier must be set in the same set frequency.
Others such as the paging address, data rate, message, repeater call time etc can be
independent either same or all in different.
■ The NP-14 Alarm contacts up to eight input control lines.
■ The NP-14 eight contacts input are all independent.
■ The NP-14 operates can be by the RS-232 serial input.
■ The NP-14 operates can be by the RJ-45 Ethernet input.
■ The NP-14 transmitter section is the frequency synthesized unit.
■ The NP-14 system communication protocol are by SCOPE, COMP2…

3
Appearance
1. DC-12V IN : 10V-13.8V In Minimum 1A.
2. Ethernet cable: Connect to the Internet HUB by Cat.5 and up cable.
3. Ethernet LED indicate
Yellow on for power ON
Yellow flash for Net 10M link
Green flash for 100M link
4. RS-232 Serial port.
Pin 2
TX (data output To PC DB-9 Pin 2 RD)
Pin 3
RX (data received From PC DB-9 Pin 3 TD)
Pin 5
GND (required to PC DB-9 pin 5)
5. Mini USB for the System programming
6. RF output to antenna or RF amplifier.

4
PROGRAMMABLE FEATURES
The photo screen below describes theNP-14 programmable features
↑Figure 2. Programming screen
Programmable and set up
While programming, the NP-14 DC plug must be off and disconnected.
Just use the DC power source from the PC USB.
Tips to set up the programming parameters
1. Install the programming AP execution file
2. Click PMX-NP and then runs the programming software.
3. Connect the USB plug into your device and the PC USB port.
If show Disconnect Check USB Jack again.

5
Example Programming Screen as Below:
Item Function Value
A- Carrier Frequency
Radio Frequency set-up
key-in your own frequency
410.000 to 490.995
850.000 to 890.995
910.0000 to 931.9375
B- TX RF Power
Transmitter RF Power set-up
The % Just for reference and
must connect with RF power
meter for the accurate output
power adjustment.
C- FSK Deviation
Frequency Deviation set-up Normal 4.0K or 4.5K (Max) for
POCSAG or 2 level data rate
D- Modulation type select
Frequency modulation set-up
Normal 2-FSK (2 level FSK) for
POCSAG
E- Data Polarity
Data Polarity in Normal or
Invert set-up
Normal = 01010101---
Invert = 10101010---
General select Normal
F- POCSAG Preamble:
Preamble for pager power
saving
Normal set 576 bits or more.
G- Page number of copcode
Pager copcode address
set-up
No 1-8 or 1-16 pager copcode can
be all same or all difference.

6
7digital POCSAG address range
from 0000008 to 2097151.
H- Pager display type
selection
Numeric or Alphanumeric
Display Pager set-up
N for numeric display type, A for
alphanumeric display type.
I- Data Rate
Data speed set-up POCSAG data speed and baud
rate in 512bps or 1200bps
Must be same as pager speed.
J- Pager alert tone
Pager alert tone select A=1beep per Sec,
B=2beeps per Sec,
C=3beeps per Sec,
D=4beeps per Sec.
K- Pre-program Message
Pre-programmed Message All ASCII words
L- Paging repeater
Repeater call times for each
paging
1=1 call
2=2 time call
3=3 time call
4=4 time call
M- Buzzer On/off select
NP-14 TX Buzzer On or Off When NP-14 transmitting, the

7
buzzer beep sound can be set
either by ON or OFF
N- Link interface select
Command interface by
RS-232 serial or by RJ-45
Ethernet
RJ-45 = Internet
RS-232 = Serial port
O- PC Communication set-up
O,P,Q,R-for Comport set up:
General set 9600,8,N,1
S- Command protocol
PC or Console command
protocol
SCOPE, TAP, Comp1, Comp2
GACOMP2….
Select 1 to meet your console
protocol
T- Number of alarm input
Select alarm input option
8 input or 16 input
The NP-14 default is 8 alarm input
only
U- Alarm Trig switch level
Select Alarm switch
from NC to NO for action
or NO to NC for action
or any (both)
Release = Normal close to open
Press = Normal open to short
Both = Normal close to open and
Normal open to close for alarm
action
V- Alarm Trig over time Duration action prohibited If set 1 Sec, then over 1 sec and

8
after the 1st activation more time is allowed for the next
alarm action. If under 1 sec. will be
no action.
X- X-for Rea :Reading the programmed contents from your devices.
W- W-for Write:Write the programming contents into your devices.

9
INSTALLATION
Introduction
This chapter provides basis information in installation help of the NP-14 Netpage
transmitter device.
Installation
Installing the NP-14 involves identifying the interface connections for communication
with the host equipment and connecting the module. The connector pin orientation is
shown in Figure 20 Corresponding signal name and color codes are listed in table
1-1.1-2.1-3.1-4.mount and connect the NP-14 as follows:
←
←←
←Figure 20. Main I/O of Rear view
Table 1-1.COM1,RS232 SERIAL PORTS (9 way female) PIN SIGNAL DIRECTION
DB9 - View looking into female
connector (NP-14 side)
1 N/C
2 RECEIVE DATA (RX) IN
3 TRANSMIT DATA (TX) OUT
4 N/C
5 GROUND (GND)
6 N/C
7 N/C
8 CLEAR TO SEND (CTS) IN
Link by RS-232
Plug the RS-232 Cable into an available DB9 serial port connector on the back of a Host Device, such
as a PC or Nurse Call system or other Host Device. If the serial port has a DB25 connector, you must
provide a DB25 to DB9 adapter, which is available from NP-14 or from a computer supply company.
Tighten the connector screws. Plug the RS-232 Cable into the DB9 female connector on the
Transmitter Unit. Tighten the connector screws again.
The RS-232 Cable is a parallel wire: Pin 5 to pin 5, Pin 2 to pin 2, Pin 3 to Pin 3.

10
Option serial RS-232 cable Part NO.86852933-00
Autres manuels pour NetPage NP-14 Series
1
Table des matières
Manuels Matériel réseau populaires d'autres marques

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuel utilisateur

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuel utilisateur

Yudor
Yudor YDS-16 Manuel utilisateur

D-Link
D-Link ShareCenter DNS-320L Manuel utilisateur

Samsung
Samsung ES1642dc Instructions d'utilisation

Honeywell Home
Honeywell Home LTEM-PV Instructions de montage