2C80 FF and C95 FF - User's
Safety
It is essential that the instructions in this booklet are strictly
followed, for safe and economical operation of the boiler.
Current Gas Safety (Installation and Use)
Regulations or rules in force.
In your own interest, and that of safety, it is the law that this
boiler must be installed by a CORGI registered installer, in
accordance with the above regulations.
Tampering with sealed components or incorrect use of the
boiler will invalidate the boiler guarantee.
Electricity Supply
This appliance must be connected to the supply via a double-
pole switch, fused at 3 A.
C80 FF ......................... G.C. Appliance No. 47 348 05
C95 FF ......................... G.C. Appliance No. 47 348 06
Natural Gas Models Only
Minimum Clearances
The minimum clearances given below must be complied
with in order to maintain the safe running of the boiler and
to facilitate servicing.
Above the boiler - 160 mm (6 1/4")
At LH side of the boiler - 15 mm (5/8")
At RH side of the boiler - 35 mm (1 3/8")
Underneath the boiler casing:
for service - 150 mm (6")
Front of the boiler:
for service - 450 mm (18")
CAUTION.
To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components.
THE LOG BOOK SHOULD BE COMPLETED AFTER
EACH SERVICE AND KEPT WITH THESE
INSTRUCTIONS
All CORGI registered installers carry a CORGI ID card, and have a registration number. Both should be recorded in your Benchmark
Log Book. You can check your installer by calling CORGI direct on 0156 372 300.

3
C80 FF and C95 FF - User's
AB CDEF
Rap 1387
Control of water temperature
DOMESTIC HOT WATER
The domestic hot water draw-off temperature is normally limited
by the modulating gas control to approximately 60 oC at the
minimum water draw-off rate of about 3.5 litre/min. (0.75 g.p.m.).
It can be varied between 60 oC and 35 oC by adjusting the hot
water temperature control (C).
CENTRAL HEATING
The boiler modulating control automatically maintains the central
heating radiator temperature between 84 oC and 40 oC by
adjusting the variable heating temperature control (B).
If your system includes a room thermostat the heating
temperature control (B) may be left in its maximum position.
If your household includes very young or elderly people you may,
however, reduce this setting, for safety reasons.
To light the boiler
(see illustration )
Summer Conditions - Domestic Hot Water Only
Set the main switch (A) to HOT WATER .
Note. Whenever domestic hot water is drawn off, the boiler will
fire to provide hot water at the tap.
Winter Conditions - Central Heating & Domestic Hot Water
Set the main switch (A) to HEATING & HOT WATER .
The boiler will fire and supply heat to the radiators but will give
priority to domestic hot water when required.
NOTE TO THE INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE HOUSEHOLDER
Important Notes
1. THIS APPLIANCE MUST NOT BE OPERATED WITHOUT
THE INNER FRONT SEALING PANEL BEING CORRECTLY
FITTED.
2. Compartment Installations
If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
Ventilation provided for boilers installed in compartments
MUST NOT be blocked, and a check should be made
periodically that the ventilation areas are free from any
obstruction.
3. If it is known or suspected that a fault exists on the boiler then
it MUST NOT BE USED until the fault has been corrected by
a CORGI registered installer.
Escape of gas
Should a gas leak or fault be suspected contact your local gas
supplier without delay.
Do NOT search for gas leaks with a naked flame.
Cleaning
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains use a damp cloth and mild
detergent.
DO NOT use abrasive cleaning materials.
Maintenance
The appliance should be serviced at least once a year by a
CORGI registered installer.
IMPORTANT - DRAINING THE SYSTEM
It is not good practice to drain off radiators to decorate behind
them. In the case of sealed system boilers, such as this, it will
lower the system pressure AND MAY CAUSE THE BOILER TO
STOP WORKING.
BOILER CONTROLS
DOverheat thermostat reset button
ESystem water pressure gauge
FProgrammer (optional)
LEGEND
AMain switch
BHeating temperature control
CHot water temperature control

Caradon Plumbing Limited pursues a policy of
continuing improvement in the design and
performance of its products. The right is therefore
reserved to vary specification without notice.
January 2001 156343 A01
Caradon Plumbing Limited, P.O. Box 103,
National Ave, Kingston upon Hull, HU5 4JN.
Telephone: 01482 492 251 Fax: 01482 448 858.
Registration No. London 322 137.
Consumer Helpline: 01482 498 660
Faults
A. No heating or hot water
Check that gas and electricity are available at the boiler and
that all switches are on.
Check that the system water pressure gauge (E) reads at
least 0.5 bar.
Check that the overheat thermostat has not tripped.
Remove cover and press button (D) to reset.
Turn the main switch (A) to OFF (O) position, wait 5 seconds
and return to desired setting.
B.Hot water but no heating
Check that the programmer and room thermostat (if fitted)
are both calling for heat.
C. Heating but no hot water
Check that cold water does flow out of the hot taps at a
minimum rate of 3.5 litres per minute (or 1 pint in 10
seconds or less).
If not, look for stop valves not fully open.
If these simple checks fail to solve the problem, or the
problem recurs, consult your service engineer.
To shut down the boiler
Set the main switch (A) to OFF (O).
When heating is again required, restore the switch to the HOT
WATER or HEATING & HOT WATER.
Frost
If no frost protection is provided and frost is likely during a short
absence from home, leave the heating control (B) at a reduced
temperature setting.
For longer periods, the entire system should be drained -
including the domestic water supply .
If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF by selecting the OFF
programme at the time control.
The mains supply should be left switched ON.
If in doubt, ask your installer.
To relight the boiler
Repeat the procedure detailed in 'To light the boiler'.
The code of practice for the installation,
commissioning & servicing of central heating systems
Caradon Plumbing Limited is a member of the
Benchmark initiative and fully supports the aims of the
programme. Benchmark has been introduced to
improve the standards of installation and commissioning
of central heating systems in the UK and to encourage
the regular servicing of all central heating systems to
ensure safety and efficiency.
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Chaudière populaires d'autres marques

Vaillant
Vaillant uniSTOR VIH SW GB 500 BES Manuel utilisateur

Radijator
Radijator BIO max 23.1 Manuel utilisateur

Brunner
Brunner BSV 20 Manuel utilisateur

Buderus
Buderus Logamax GB062-24 KDE H V2 Manuel utilisateur

Potterton
Potterton 50e Fiche technique

UTICA BOILERS
UTICA BOILERS TriFire Manuel utilisateur