FITTING INSTRUCTION
WESTBO WeRa
Westbo of Sweden

Westbo of Sweden
Westbo WeRa General instructions
Building notication
Before installation of the replace and construction of a
chimney, it is a demand to do a building notication.
For piece of advise, contact your local authorities.
When receiving the stove
When the stove is received it is important to check the goods
to see that the stove is not damaged during the transport.
Damages should be notied to the freight company immedia-
tely.
Floor protection
The oor protection prevents the oor in front of the stove from
sparks. Check your local regulations by your domestic autho-
rites.
Flue inspection
A good piece of advice when installing to the existing chimney
is to before start, contact the Chimney sweeper for
inspection. The Chimney sweeper can recommend
possible need for chimney renovation.
After installing the replace, it must be inspected by a
Chimney sweeper again before it is put into operation.
Supporting material
The product weight is 150 kg and can be placed on an
ordinary oor.
Combustible and non-combustible wall
The stove does not require a rewall but is approved to
place it 400 mm from the back edge to the combustible wall.
When placed against non-combustible wall (rewall), a mini-
mum distance of 100 mm must be kept.
Heating and care instructions
See in particular section in this guide.
Standards
National and European standards, building regulations and
rules must be observed.
Therefore, inform your Chimney sweeper in advance.
The chimney calculation is carried out according to DIN EN
13384- 1 or YOUR EN 13384-2.
Please read this brochure carefully and the chimney
suppliers instructions before starting assembly.
Good luck with your new replace!
Westbo of Sweden

Westbo of Sweden
Westbo WeRa Fitting instruction
Legs and Chamotte bricks must be mounted in the rebox.
Use mounting option one or two.
Includning:
4 Legs and screws
6 Chamotte bricks
1 Air box
1 Handle
1 Smoke pipe 125 mm in diameter
Chamotte bricks
Combined with the stove there are six Chamotte bricks.
S1 och S2 - Side bricks
S 5 - Bottom brick
S 6 - Rear brick
S 3 -and S 4 - Baffele plates
Place the bricks shown on this page.
Legs and Chamotte bricks must be mounted on the rebox.
Use mounting options one or two.
1. Disassemble the top plate from the rebox and lift it off.
First, place the left side brick (S1) in the rebox.
2. Then insert the second side brick (S2).
Be careful on the orientation of the side stones so the airholes
are in correct position.
3. Then insert the bottom brick (S5) and the rear brick (S6).
4. Place the baffele plates (S3) and (S4) towards the back so the
gap for the smoke is in the front.
Reassemble the top plate.
The replace is now ready. Install the handle.
In some cases, a smaller piece of the side brick (S2) needs to be
knocked away in order to that handles and door should be able
to close correctly.

Westbo of Sweden
Westbo WeRa Fire advise
Safety
Westbo WeRa is tested according to the DIN standard DIN
13240.
The stove is room air dependent, i.e., the combustion air is
consumed from the installation room. Make sure that an ade-
quate air supply is ensured.
The stove is equipped with a control for supply air to the com-
bustion and is located above the rebox.
Observe the distances to ammable objects. Do not leave
paper, newspapers or other combustible materials near the
stove.
The stove can be hot!
Risk of burns on all surfaces: combustion chamber door, door
and control handles, smoke pipes and the front of the stove.
Do not leave children unattended near the stove.
Empty the ashes
Never drain ash into a combustible vessel, preferably use a
sheet metal vessel with a tight tting lid. There may be ember
residues in the ashes several days after the end of the re.
Smell
At the rst ring, some odors may appear.
It is due to certain coatings on the plate that are burned off.
The smell disappears after a couple of bonres.
First re
We advise you to use ignition pads or equivalent. With
the help of these, there will be a quick over ignition of the
wood and a cleaner combustion.
Never use lighter uid.
At rst ignition, the supply air control shall be fully opened.
Put in about 1-2 kilograms of kindling wood (thin logs).
Put a 2-3 kindling pads on top and light on. Close the
door when the re has started. With this method, there
will be a quick over ignition and it minimizes soot coating
on the glass.
When lling wood, carefully open the door so that smoke
rash is avoided. Never ll up with wood as long as it burns
a lot.
Continuous ring
It is important to get the right temperature in the replace.
Then the stove and wood are utilized to the maximum
and there will be a clean combustion. Soot coating in the
rebox and on the glass is also avoided.
When red correctly, the smoke should not be visible, but
only perceived as a dripping in the air.
In the case of a good ember bed after the ignition pha-
se, the actual ring can begin with the right amount of
rewood.
Now adjust the supply air control relative to the draught
in the chimney. It should burn well, if it is strangled too
much, there is a risk of soot coating in the rebox, as well
as sooting on the glass.
Recommend amount of wood
We recommend smaller wood logs, that can be placed in
the stove. Length of wood is approximately 20 cm and at
the most 3 kg. The maximum amount of wood allowed is
approximately 3 kg per hour for dry cut birch wood.
Sweeping
Sweeping should be done by the Chimney sweeper.
Sweeping of the stove can be done by scraping down
and/or brushing. To collect the ashes, the most suitable
is to use a soot vacuum cleaner.
Chimney re
If a chimney re occurs or is feared, dampers and hatches
must be closed. If necessary, contact emergency services
for extinguishing. After a chimney re, the chimney must
always be inspected.

Westbo of Sweden
Westbo WeRa Wood handling
Preparation
We recommend a diameter of 6-10 centimetre and that the
wood logs are 6 centimetre shorter than the replace.
This will help the air to circulate in the best possible way. If the
diameter is bigger, the wood logs must be splitted. Wood logs
that are splitted will dry better.
Storage
The splitted wood logs should be stored for 1-2 years before
usage. If the wood is put in piles it will dry faster. Before use,
store the wood in room temperature. Please keep in mind that
the wood during Autumn and Winter absorbs moist from the
air.
Moisture
To avoid environmental problems and to get the best fuel-
ling economy, the wood logs must be dried before use. They
should contain maximum 21% moisture. Best performance
of the wood logs is achieved by a moisture level of 15-18%.
A simple test is to beat two wood logs against each other.
If a numb sound occurs, the wood contains too much moist.
By using moist wood logs, large amount of the heat will be
used to evaporate the water. The stove will therefore not be
warm. This is of course uneconomic and there will be soot on
the glass hatches, inside the stove and in the chimney. The
environment will also be contaminated.
What is correct amount of wood logs?
How much is a kilo of wood? Or how do you handle the wood
in a correct way? There are literature to buy regarding wood
knowledge. It is a good thing to acquire a little more knowled-
ge on the subject than what we communicate here.
It is absolutely forbidden to re:
Painted, pressure-treated or glued wood. Neither is chipboard,
plastic, or treated paper suitable to re. The substances con-
tained in these products are harmful both to the environment
and to the stove. Even the chimney can be attacked if you
use material mentioned above.
Simply put, re only clean wood logs.
Caloric wood value
The caloric wood value varies between wood species. On
some you need to put a bit more wood into the replace to get
the same amount of heat like other wood species. In our ring
instructions, we calculate with birch wood, which has a very
good caloric value and is the type of wood we recommend.
By burning oak or beech, keep in mind that these types of
wood have a higher caloric value than birch. Wood logs
must also be reduced so the stove won’t be damaged.
Pine and spruce have higher caloric value than birch.

Westbo of Sweden
Westbo WeRa Technical data
Technical data
Weight 150 kg
Height 69 cm
Width 43,5 cm
Deep 59 cm
Cooking plate 270 mm diameter
Smoke channel 125 mm diameter
Material Cast iron
Medium power 7,0 kW
Efcency 80%
Distance to combustable wall/side 400 mm
CE-approved According to EN 13240
504
703
218
178
448
358
A
A
BB
539
270
450
40
220
601
A-A
280
450
B-B
270
128
539
440
WeRa M2 1 2
Feb.10.2022
Drawn
Checked
Date
SAM
Size A4
SAM
Sheet
of
Doc.Nr

Westbo WeRa EU-declaration

Westbo of Sweden
Westbo WeRa Guarantee
Issue 23-02
Westbo of Sweden has a 10 year stove casting warranty and a 1 year
warranty concerning natural wear and tear of articles of consumption
such as firebricks, vermiculite, grates, glass, handles and rope seal.
The warranty is only valid if the stove has been used in a proper way
according to the instructions and will not be valid if any extreme or
careless handling has occurred like overheating, wrong fuel or too much
wood etc.
Westbo of Sweden is obligated to provide new parts/stove if any defects
covered by the warranty occurred, but takes no responsibility for removal
or installation costs for the exchange.
The warranty covers only the product and the buyer is not entitled to
compensation for any personal or property damage.
Yours sincerely
Mattias Gunnarsson
Managing director
WARRANTY
Table des matières
Autres manuels Westbo Poêle
Manuels Poêle populaires d'autres marques

Vermont Castings
Vermont Castings Intrepid 2 Manuel utilisateur

Italiana Camini
Italiana Camini CLASSICA Guide de démarrage rapide

Avalon
Avalon Vashon Avanti DVS FS Manuel utilisateur

Spartherm
Spartherm ambiente a1 Manuel utilisateur

Dimplex
Dimplex MCFSTV12AU Manuel utilisateur

Warmlite
Warmlite WL46040 Manuel utilisateur