Weishaupt WWP-RG1 Manuel utilisateur

Installation and operating instruction
Room device WWP-RG1 83316002 1/2019-08

Installation and operating instruction
Room device WWP-RG1
83316002 1/2019-08 La 2-20
1 User instructions.............................................................................................................. 3
1.1 Target group.................................................................................................................. 3
1.2 Symbols.......................................................................................................................... 3
1.3 Guarantee and Liability............................................................................................... 4
2 Safety ..................................................................................................................................... 5
2.1 Designated application............................................................................................... 5
2.2 Safety measures........................................................................................................... 5
2.3 Disposal ......................................................................................................................... 5
3 Product description ........................................................................................................ 6
3.1 Type key ......................................................................................................................... 6
3.2 Technical data............................................................................................................... 7
3.2.1 Electrical data ........................................................................................................7
3.2.1.1 Electrical data..................................................................................................7
3.2.2 Ambient conditions...............................................................................................7
3.2.3 Dimensions .............................................................................................................7
4 Installation ........................................................................................................................... 8
5 Operation .......................................................................................................................... 10
5.1 Display and operating unit .......................................................................................10
5.2 Display..........................................................................................................................11
5.2.1 Display room humidity....................................................................................... 11
5.3 ManualOperation........................................................................................................12
5.4 Absence .......................................................................................................................12
5.5 Party mode ..................................................................................................................13
5.6 Automatic operation ..................................................................................................13
5.7 Set room setpoint temperature...............................................................................14
5.8 Service level ................................................................................................................15
5.8.1 Check assignment ............................................................................................. 15
5.8.2 Adjusting the room temperature..................................................................... 15
5.8.3 Set brightness in setting mode....................................................................... 16
5.8.4 Set brightness in standby mode..................................................................... 16
6 Commissioning.............................................................................................................. 17
7 Fault ..................................................................................................................................... 18
8 Key word index .............................................................................................................. 19

Installation and operating instruction
Room device WWP-RG1
1 User instructions
83316002 1/2019-08 La 3-20
1 User instructions
Translation of original
operating instructions
This manual forms part of the equipment and must be kept on site.
Carefully read the manual prior to working on the unit.
It is supplemented by the installation and operating instructions for the heat pump.
1.1 Target group
The manual is intended for the operator and qualified personnel. It should be ob-
served by all personnel working with the unit.
Work on the unit must only be carried out by personnel who have the relevant train-
ing and instruction.
In accordance with EN 60335-1 the following requirements apply
This appliance can be used by children 8 years and above as well as by persons
with limited physical, sensory or mental capacities or lack of experience and know-
ledge, provided they are supervised or have been instructed regarding the safe use
of the appliance and understand the resulting danger. Children must not play with
the appliance. Cleaning and operator maintenance must not be carried out by chil-
dren without supervision.
1.2 Symbols
DANGER
Immediate danger with high risk.
Non observance can lead to serious injury or death.
WARNING
Danger with medium risk.
Non observance can lead to environmental damage,
serious injury or death.
CAUTION
Danger with low risk.
Non observance can cause damage to the equip-
ment and injury to personnel.
Important information
Requires direct action
Result after an action
Itemisation
… Range of values

Installation and operating instruction
Room device WWP-RG1
1 User instructions
83316002 1/2019-08 La 4-20
1.3 Guarantee and Liability
Guarantee and liability claims for personal and equipment damage are excluded, if
they can be attributed to one or more of the following causes:
non approved application,
non-observance of the manual,
operation with faulty safety equipment,
continual operation despite a fault,
improper installation, commissioning, operation and service,
repairs, which have been carried out incorrectly,
the use of non original Weishaupt parts,
force majeure,
the installation of additional components, which have not been tested with the
unit.

Installation and operating instruction
Room device WWP-RG1
2 Safety
83316002 1/2019-08 La 5-20
2 Safety
2.1 Designated application
The room device in conjunction with the Weishaupt heat pumpWWPLS and
WWP LB is suitable for the room management of a heating circuit.
Up to 3room devices can be used. Each of these 3room devices can be assigned
to a heating circuit.
The device should only be used indoors.
The installation location must comply with local regulations and must be frost-proof.
Improper use could:
endanger the health and safety of the user or third parties,
cause damage to the unit or other material assets.
2.2 Safety measures
Safety relevant fault conditions must be eliminated immediately.
2.3 Disposal
Dispose of all materials and components in a safe and environmentally friendly way
at an authorised location. Observe local regulations.

Installation and operating instruction
Room device WWP-RG1
3 Product description
83316002 1/2019-08 La 6-20
3 Product description
3.1 Type key
WWP-RG1
WWP Series: Weishaupt heat pump
RG1 Type: room device

Installation and operating instruction
Room device WWP-RG1
3 Product description
83316002 1/2019-08 La 7-20
3.2 Technical data
3.2.1 Electrical data
3.2.1.1 Electrical data
Voltage supply via Bus line
Consumption max 0.7W
Type of protection IP20
3.2.2 Ambient conditions
Temperature in operation 0... +50°C
Temperature during transport / storage 0... +50°C
relative humidity max 85%, no dew point
Installation elevation max 2000 m(1
(1 Consultation with Weishaupt is required for higher installation elevation.
3.2.3 Dimensions
80 mm
80 mm

Installation and operating instruction
Room device WWP-RG1
4 Installation
83316002 1/2019-08 La 8-20
4 Installation
DANGER
Risk of electric shock
Working on the device when voltage is applied can lead to electric shock.
Isolate the device from the power supply prior to starting any work.
Safeguard against accidental restart.
CAUTION
Damage to the PCB due to electrostatic discharge (ESD)
PCB can be damaged by contact.
Do not touch the PCB and its components.
The electrical connection must only be carried out by qualified electricians. Ob-
serve local regulations.
Secure wall bracket1 to the wall using the screws supplied.
Feed the wires2 through and connect the plug to the wiring diagram.
WWP
A B
A B
2
1

Installation and operating instruction
Room device WWP-RG1
4 Installation
83316002 1/2019-08 La 9-20
Insert the lugs1 of the room device into the recesses2.
Click room device into place downwards.
1
2
Pull off protective foil.

Installation and operating instruction
Room device WWP-RG1
5 Operation
83316002 1/2019-08 La 10-20
5 Operation
5.1 Display and operating unit
2
3
5
1
4
Keys
1Manual Operation [ch.5.3]
2Absent [ch.5.4]
3Party mode [ch.5.5]
4Automatic operation [ch.5.6]
Dial knob
5turn select or change values
press briefly: confirm or save values
In setting mode:
approx. 3seconds: exit value without saving / back to standard
display
In standard display:
approx. 3seconds: display room humidity
Table des matières
Autres manuels Weishaupt Thermostat
Manuels Thermostat populaires d'autres marques

EWELLY
EWELLY EW-181 Manuel utilisateur

Prolon
Prolon T1100 Instructions d'installation

Computherm
Computherm Q20 Manuel utilisateur

Heatmiser
Heatmiser neoStat Manuel utilisateur

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manuel utilisateur

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manuel utilisateur