Wallgate e-Suite Tap Manuel utilisateur

Product Manual
e-Suite Tap
Traditional Tap with
Electronic Control

Revision 3
2
Product Manual e-Suite Tap

Revision 3
3
Product Manual e-Suite Tap
Table of Contents
1. Disclaimer ..........................................................................................................................4
2. Conventions .......................................................................................................................5
2.1 Warning............................................................................................................................5
2.2 Note .................................................................................................................................5
2.3 Numbered procedures......................................................................................................5
2.4 Bullet lists........................................................................................................................5
2.5 Menu items.......................................................................................................................5
3. Glossary.............................................................................................................................6
4. Overview............................................................................................................................7
5. Package Contents..............................................................................................................7
5.1 Mounting Guidelines.........................................................................................................8
5.2 e-Suite Tap disassembly...............................................................................................15
5.3 e-Suite Tap installation...................................................................................................16
5.4 Water Connections.........................................................................................................17
5.5 Fitting the electronic encoder housing............................................................................18
5.6 Mounting the WDC.........................................................................................................19
5.7 Setting stops .................................................................................................................20
5.8 Commissioning for Use .................................................................................................21
5.9 Technical Specifications................................................................................................21
6. User and Maintenance Instructions ..................................................................................22
6.1 Operation .......................................................................................................................22
6.2 Maintenance...................................................................................................................23
7. Related Documentation....................................................................................................23

Revision 3
4
Product Manual e-Suite Tap
1. Disclaimer
Every effort has been made to supply information within this manual which is correct.
Wallgate Limited will not be liable for any damage or loss that arises if the person
installing, operating or maintaining the unit has not read or not complied with the
manual
In any event, and without prejudice to any warranties in Wallgate Limited’s terms and
conditions of sale, Wallgate Limited’s liability for all damages and losses (including
negligence) shall not in any circumstances exceed the amount paid by the customer
for the unit.
Wallgate reserves the right to alter, update or improve its product specification at any
time without prior notice. This manual is specific to the product that it has been
supplied with at the date of supply.
Without prejudice to any warranties in Wallgate Limited’s terms and conditions of
sale, any warranty will be invalidated if the equipment is installed or serviced by
unqualified personnel.
No part of this publication and the information contained may be reproduced,
transmitted, stored in a retrieval system, used or disclosed wholly or partly without
prior written permission from Wallgate Limited.
For full warranty details please see Wallgate Limited Terms and Conditions.
Please ensure this manual is passed to the end user. The manual forms an integral
part of the product and should be kept for its working life. Additional copies of this
and other supporting documents are available by contacting Wallgate Ltd or by
visiting www.wallgate.com

Revision 3
5
Product Manual e-Suite Tap
2. Conventions
Certain conventions are used in this manual to make it easier to read and
understand. They are given in the sections below.
2.1 Warning
A warning with white text on a red background is used to give information about
hazards that can cause injury or death. Read and understand these warnings before
you install and commission the e-Suite Tap. Failure to heed these warnings can have
serious consequences.
WARNING! This is a warning!
2.2 Note
A note with black text on a yellow background is used to draw your attention to
important and useful information.
NOTE: This is a note.
2.3 Numbered procedures
Steps in procedures are numbered, starting from 1.
1. This is step 1.
2. This is step 2 etc.
2.4 Bullet lists
•A bullet list is used to give information that is not sequential.
2.5 Menu items
Menu items, submenu items and settings, where available, are given in bold.

Revision 3
6
Product Manual e-Suite Tap
3. Glossary
The glossary lists all words, abbreviations and technical terminology used in this
manual, along with a short description of these terms.
Term
Description
Encoder Housing
The tap electronics fitted in a plastic housing attached to
the bottom of the tap. (Item 9 on Figure 3)
BSP
The British Standard Pipe (BSP) thread is a family of
standard screw thread types that has been adopted
internationally for interconnecting and sealing pipe ends
by mating an external (male) with an internal (female)
thread.1
Tectite push fit
Tectite push fit type fittings are a plumbing pipe
connector that pushes onto the copper tube and has an
integral rubber seal to ensure a water tight connection.
The tap utilizes an individual Tectite push fit T for water
connection.
1
Description sourced from Wikipedia at http://en.wikipedia.org/wiki/British_standard_pipe_thread

Revision 3
7
Product Manual e-Suite Tap
4. Overview
The e-Suite Tap is a pillar tap of traditional appearance, which provides electronic
control of water flow, when used in conjunction with a Wallgate WDC100/200e
electronic controller. The use of the tap with an electronic controller allows a range of
adjustable, automatic functions as detailed in the controller product manual; including
automatic run time, hygiene purge and data logging.
5. Package Contents
Before you begin the installation, make sure that you have the following items:
✓1 Product manual
✓1 e-Suite tap kit (contains 2 taps with encoders and connection cables)
✓2 WS3848 Proportional flow solenoid valve (1 per tap)
The following items are NOT included in the pack but required for installation.
•1 WDC100e or WDC200e electronic controller (available from Wallgate)
•1 Thermostatic mixing valve (available from Wallgate) is recommended to provide
temperature controlled water to the “hot” tap.
NOTE: The WDC100e / 200e electronic control unit is required and supplied
separately. Various controller options are available, contact the Wallgate sales
desk for more information.

Revision 3
8
Product Manual e-Suite Tap
5.1 Mounting Guidelines
•The e-Suite Tap is designed to be mounted on a Wallgate vanity top or basin but
is compatible with many others. If the tap is to be used with a non Wallgate basin,
ensure there is sufficient space for the water connections to the tap; see Figure 1
for dimensions.
•Hot and cold water supplies are necessary. See Table 1 on page 16 for the
specifications of the water supplies.
•The hot water supply should be fitted with a thermostatic mixing valve, prior to
the solenoid valve, to prevent risk of injury to users & to protect the solenoid
valve.
•An electrical supply of 230V 50Hz with a 2 Amp rating is required for the optional
electronic control units.
•The E-suite taps are to be used in conjunction with a WDC100e or WDC200e,
this version of the WDC has no automatic hygiene purge feature to conform to
WRAS requirements.

Revision 3
9
Product Manual e-Suite Tap
Figure 1: e-Suite Tap details

Revision 3
10
Product Manual e-Suite Tap
Figure 2: e-Suite Tap & controls typical installation layout.
Table des matières
Autres manuels Wallgate Appareil de salle de bains