VWR A-1001 Manuel utilisateur

Instruction manual
VWR A-1001/A-1101/A-1201
Sipper/Temperature Control System
European Catalogue Number
EU/UK/CH Plug: 634-1138 A-1101 CONTROLLER, SIPPER
EU/UK/CH Plug: 634-1139 A-1001 CONTROLLER, SIPPER WITH
CONSTANT-TEMPERATURE
EU/UK/CH Plug: 634-1140 A-1201 CONTROLLER,
CONSTANT-TEMPERATURE
Version: 1.0.1
Issued: 16, June 2020

2
Legal Address of Manufacturer
Europe
VWR International bv
Researchpark Haasrode 2020
Geldenaaksebaan 464
B-3001 Leuven
+ 32 16 385011
www.vwr.com
Made in China

3
Table of Contents
Safety Information ......................................................................................................................................................... 4
Package Contents ........................................................................................................................................................... 5
Unpacking ..................................................................................................................................................................... 7
Description .................................................................................................................................................................... 7
Installation .................................................................................................................................................................... 8
Symbols and conventions .............................................................................................................................................. 11
Product Specifications .................................................................................................................................................. 11
Getting Started ............................................................................................................................................................ 13
Using the instrument .................................................................................................................................................... 14
Operation .................................................................................................................................................................... 16
Temperature Control ......................................................................................................................................... 16
Sipper ................................................................................................................................................................17
System settings............................................................................................................................................................. 20
Technical service .......................................................................................................................................................... 21
Warranty..................................................................................................................................................................... 21
Compliance with local laws and regulations ................................................................................................................... 22
Equipment disposal ...................................................................................................................................................... 22
Local VWR offices in Europe and Asia Pacific................................................................................................................ 23

4
Safety Information
Please follow the guidelines below and read this manual in its entirety to ensure safe
operation of the unit.
We recommend against the use of A-1000 Constant Temperature/Automatic Injection
System.
Do not open the device.
Disconnect the device from the mains supply before carrying out
maintenance work or changing the fuses.
The inside of the device is a high-voltage area Danger!
Do not use the device if it is damaged, especially if the main power cable
way is in any damaged or defective.
Repairs may only be carried out by the service technicians from your
authorized contractual partners.
The device must be connected to a power outlet that has a protective
ground connection.
If the equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Do not allow any liquid to enter into the device.
Do not operate the device in a hazardous location or potentially explosive
environment.

5
Package Contents
Configuration list of A-1001
Description
Quantity
Constant Temperature/Automatic Injection Controller
1PC
10mm Single Cell Holder with Constant Temperature
1PC
10mm Flowing Quartz Cuvette
1PC
Sample Chamber Baffle (including constant temperature interface, injection hole)
1PC
Silicone Pipe with Limit Ring(1m,Inner hole diameter:φ2,Outer diameter:φ4)
1PC
Silicone pipe(700mm,Inner hole diameter:φ2,Outer diameter:φ4)
1PC
Constant Temperature Control Cable
1PC
Power Cords ( EU/UK/CH Plug )
1PC
Instruction Manual
1PC

6
Configuration list of A-1101
Description
Quantity
Automatic Injection Controller
1PC
10mm Single Cell Holder
1PC
10mm Flowing Quartz Cuvette
1PC
Sample Chamber Baffle (including injection hole)
1PC
Silicone Pipe with Limit Ring(1m,Inner hole diameter:φ2,Outer diameter:φ4)
1PC
Silicone pipe(700mm,Inner hole diameter:φ2,Outer diameter:φ4)
1PC
Power Cords ( EU/UK/CH Plug )
1PC
Instruction Manual
1PC
Configuration list of A-1201
Description
Quantity
Constant Temperature Controller
1PC
10mm Single Cell Holder with Constant Temperature
1PC
Sample Chamber Baffle (including constant temperature interface)
1PC
Constant Temperature Control Cable
1PC
Power Cords ( EU/UK/CH Plug )
1PC
Instruction Manual
1PC

7
Unpacking
Open the package, according to carefully check the packaging packing list items, if
found inside the packaging are missing or damaged items please contact your
authorized contractual partners.
Description
The A-1001 series Constant Temperature/Automatic Injection Controller is specially
developed to meet the needs of some applications of our UV/Vis spectrophotometer.
It is divided into 3 models according to different functions. Model A-1001: Sipper
with Temperature Control, model A-1101: Sipper, model A-1201: Temperature
Control.
1
2
457
8
9
6
3
10
12
11
13

8
1 –Touch Screen
2 –Injection Pipe
3 –Peristaltic Pump
4 –USB Port
5 –Constant Temperature Control Port
6 –Serial Port
7 –Power Inlet
8 –Fuse Seat
9 –Power Switch
10 –In Hole
11 –Constant Temperature Control Interface
12 –Out Hole
13 –Thermostatic Single Sample Holder
Installation
Placement
Place the instrument on the stable table carefully.
Install thermostatic single sample holder
Turn off the power of the instrument. Remove the original sample holder, and remove
the original door insert. As shown in the figure, attach the thermostatic sample holder
and tighten the two screws shown by the arrows.

9
Connect the power cord
Check to confirm instrument power switch is turned off. Plug the female of the power
cord into the power inlet of the instrument and plug the male into the power outlet.
1 –Power inlet
2 –Power cord
3 –Power outlet
Connect the constant temperature control cable
The instrument is turned off. As shown in the figure, insert one end of the constant
temperature control cable into the thermostat interface on the outside of the
spectrophotometer door insert and the other end into the constant temperature
control interface on the back of the controller.
1 –Constant Temperature Control Port
2 –Constant Temperature Control Cable
3 –Constant Temperature Control Interface
13
2
1
3
2

10
Connect the injection pipe
As shown in the figure, insert the output end of the injection pipe (label 1) through
the in hole of the cover and insert the injection end of the flow cuvette (label 2). One
end of the sample discharge pipe (label 5) is connected to the sample end of the flow
cuvette (label 2), and the other end is passed through the sample hole of the cover
plate.
1 –Injection Pipe
2 –Flowing Cuvette
3 –Sample Container
4 –Waste Collection Container
5 –Sample Discharge Pipe
1
5
2
3
4
Ce manuel convient aux modèles suivants
5
Table des matières
Manuels Régulateurs de température populaires d'autres marques

Swegon
Swegon LUNAd MB Manuel utilisateur

Lucky Reptile
Lucky Reptile Thermo Control II Manuel utilisateur

SENSORMETRIX
SENSORMETRIX Argon 100 Manuel utilisateur

Fuji Electric
Fuji Electric PXE4 Manuel utilisateur

Yuyao gongyi
Yuyao gongyi XMT-808 series Manuel utilisateur

Selec
Selec TC544C Manuel utilisateur