07
Carefully unpack your Vissari inline
fan motor, either the 1030m3/hr or
1800m3/hr.
Connect the two reducer/expander
fittings (315mm/200mm or 250mm
/200mm) to the inline fan motor, please
note inline fan airflow direction.
Connect 6m x 200mm flexible ducting
to the rangehood (air in-take) end of
the inline fan.
Connect 3m x 200mm semi rigid ducting to the (air out-take) end of the inline fan.
Choose a suitable inline fan hanging installation position within your accessible ceiling area,
recommended and optimum installations use the whole 6m x 200mm flexible ducting length
between the inline fan motor and the actual rangehood at kitchen level.
The inline fan motor must not be installed in a position where it is touching any other form
of timber, ceiling, or pipework etc. The inline fan motor must hang freely to absorb all
operating fan motor noise.
Screw a threaded eye screw to a suitable roof truss or specially installed solid timber
support position.
Thread the adjustable pull tie down through the two hanging points on the inline fan motor.
9 While supporting the inline fan, now thread the pull tie down through the pre-installed
hanging eyelet, adjust to the finished suitable hanging height.
Run the 200mm semi rigid ducting to the chosen wall vent location, cut out a 210mm hole in
the wall cladding, install a 200mm trade seal to the building wrap to seal and protect your
homes weatherproof envelope when and where possible, and connect the semi rigid ducting
to the 200mm wall vent. Do not reduce ducting size.
Run the 6m x 200mm flexible ducting back to the Vissari rangehood at kitchen level, connect
neatly using cable ties and tape. Do not reduce ducting size.
Run the inline fans power cable back to the Vissari rangehood at kitchen level and plug into
the female plug.
Plug in your Vissari rangehood to the power supply at kitchen level, test the rangehood and
inline fan motor.
Warning - your quiet cooking experience starts here.
INSTALLATION WALL OPTION
VWD200 - 200mm Ducting