Veko Magnus Manuel utilisateur

MANUAL - VEKO LINEAR LIGHTING SYSTEM
IP65
Magnus
This manual is for usage with shown
product families on this page
in IP65 specification only.
In combination with the following
linear lighting profiles:
PWR-05500
•
PWR-05500-B
•
For further information of applicable
profiles, see section 3 of this manual.
Joris
Justin
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29
1/16

Table of contents
Mounting
Coupling
Mounting brackets
Power feed with cable gland
Power feed with Wieland connectors
Single unit (re-) placement
Sensor MD-L (re-) placement
Sensor configuration(s)
Pool
Emergency LED indicator & battery replacement
Emergency system info & disclaimers
General disclaimers
Page
3, 4
5
6
7
8
9
10
11, 12
13
14
15
16
IP65
2/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Table of contents

Mounting - suspension
1 2
3
4
1 Disconnect the mains.
2 Example of a light-line.
3 In regular conditions a 2 point suspension
is used.
Note
: a light-line consists of multiple part
segments. the middle linepart may vary in quantity.
Note:
measurement F is half of measurement E,
deviding E equally over 2 lineparts.
4 In case of:
- Cable duct
- Sports utility
- Swimming pool
Always use a suspension with at least 3 points.
IP65
Measurement
Recommended
length (mm)
Maximum
length (mm)
A
na.
4600
B
na.
3060
C
750 1150
D
2700 2700
E
2300 2600
F
1150 1300
G
ca. 1500
1700
Measurement
Recommended
length (mm)
Maximum
length (mm)
A
na.
4600
B
na.
3060
C
750 1150
D
ca. 1500
1700
3/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Mounting

Mounting
6 7
8 9 10
11 12 13
14 15
6 In case of mounting in concrete ceiling, Veko
recommends a MM04 anchor or similar with
according drill sizes.
7 In case of using a hook on a sheet piling roof
structure, Veko advises to drill the hole in the
center of the profile.
8 Example with KDW-hook, pendula and steel-
wire (left). KDW-hook, chain and S-hook (right).
9 Always close the links of both the KDW-
and S-hook.
10 Close the link of the S-hook.
11 Close the link of the KDW-hook.
12 Example of mounting with threaded end.
13 Example of mounting with caddy.
14/ 15 When the linear lighting is placed inside
the cannelure of the sheet piling, it's recommended to
use a metal strud or strip to secure the linear lighting
to the metal roof structure.
IP65
KDW-Hook
4/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Mounting

Coupling
1 2
4 5
7 8
10 11
1 Disconnect the mains before operating
the linear lighting system.
2 Example of connected profiles.
Note
: Profile
and/or brackets may vary.
3 The flatcable is provided with a curl for extra
length for an easy connection. Pull out and ex-
tend the flatcable.
-other.
8 Press profiles together.
9 Tighten Hexagon M5 screws (2x) on both
sides of the profiles.
10 Hook the coupling plate into the profiles.
11 Rotate the plate into position.
12 Tighten the slotted M6 bolts (4x).
IP65
6
9
3
12
4 Make sure the male connector is positioned
outside the profile, with the backside onto the
edge of the connection plate.
5 Align both profiles.
6 Insert the connector through the plate
and seals.
7 Make sure connectors firmly 'click' into each-
5/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Coupling

Overview of mounting brackets and couplings
Profile
Mounting
Coupling
Note:
Applicability of bracket may vary, depending on the surrounding, light-line configuration, light-line application and/ or IP-class.
IP65
6/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Bracket overview

Power feed with cable gland
1 2
7 8
10 11 12
13 15
1 Switch off the mains before operating
the linear lighting system.
2 Contents.
3 Use a slotted screwdriver to punch out the
desired hole(s) for the cable gland(s).
4 Remove the remaining piece(s).
5 Fit the cable gland(s).
6 Fasten the cable gland nut(s).
7 Route wiring through the cable gland and
fit with either male or female connector (depen-
ding on counterpart on the linear lighting system).
8 Insert the connector.
9 Connectors should firmly 'click' into eachother.
10 Tighten the M5 hexagon bolts on both sides-
- of the light-line.
11 Hook the coupling plate into the profiles.
12 Rotate the plate into position.
13 Tighten the M6 bolts (4x).
15 After reassuring all electrical connections
are correctly in place and corresponding,
switch the mains back on.
IP65
9
6543
14
Item
Qty.
Power Feed
1x
Connection plate
1x
Connector female
1x
Connector male
1x
Cable gland PG13,5
2x
7/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Power feed with Cable gland

Power feed Wieland
1 2
3
6 7
4
1 Disconnect the mains before operating
the linear lighting system.
2 Contents.
3 Connect the wiring with the flatcable connectors.
4 Connectors should firmly 'click' into eachother.
9 Connect the feed to the main grid using
the Wieland connectors.
10 After reassuring all electrical con-
nections are correctly in place and
corresponding, switch the mains back on.
IP65
5
89 10
5 Place the feed onto the light-line, aligning the
connection plates. Tighten the M5 Hexagon bolts (2x)
on both sides of the light-line.
6 Hook the coupling plate into the profiles.
7 Rotate the plate into position.
8 Tighten the M6 bolts (4x).
Item
Qty.
Power feed
1x
Coupling plate (with
4x slotted M5 bolt)
1x
8/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Power feed Wieland

Single unit (re-)placement
1 2
4 5 6
7
10
1 Disconnect the mains before operating the
linear lighting system.
Note
: Type of unit
and/or profile may vary.
2 Make sure poles and wiring are in correct
position.
3 Insert connector to the flatcable.
4 Press and mount the fallout safety clip into-
9 In case of a sports or emergency unit, place
extra
safety clips onto the unit- and profile,
5 on either side
of the unit, equally devided.
10
Caution
: Bracket may contain sharp edges.
11
Caution
: Make sure wiring doesn't get stuck
between the unit and the profile and
is placed
properly inside the linear lighting system.
- the profile.
5 Press the unit into the profile.
6 Mount the sealing and pressure plate(s)
onto the bracket.
7 Tighten the screw(s).
8 Mount the locking clips (6x), 3 on each side
of a single unit or blindplate.
IP65
11
8
9
3
9/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Single unit (re-) placement

Sensor MD-L (re-)placement
1 2 3
4 5 6
7 8
MD-L-Na
MD-L-R
1 Disconnect the mains before operating the
linear lighting system.
2 Example of sensor.
Note
: type of sensor and/or
profile may vary.
3 Make sure poles and wiring are in correct
position.
4 Insert connector to flatcable.
5 Press and mount the fallout safety clip
into the profile.
6 Fit the sensor unit into the profile
7 In case of the narrow lens, a cover
can be used to limit the reach of the
sensor beam if necessary.
- Length -
- Width -
9
-This cover can be cut to size with pliers
or scissors on the breakline to achieve the desired
reach and angle of the sensor beam.
8 Technical data.
9 Sensor reach:
MD-L-R (round lens)
MD-L-Na (narrow lens)
IP65
Technical data
Power (W)
1,5 W < 4 W (Switched off- < on)
Voltage (V)
220-240 V
Length (mm)
300 mm
Frequency (Hz)
50 ÷ 60 Hz
Circuit
6 A
Sensitivity settings
5 (standard max. sensitivity)
Twilight circuit
Adjustable in 9 steps 0-1.000 Lux
Switch-off delay relay
Relay 0-99 minutes
Environment application
-25 °C - + 35 °C
Corridor function / dynamic switch (example:
10-100 %)
In combination with DALI driver and control
gear
Programming
Readout and re-programmable by colour coding
with LED in sensor
PIR detection angle
Round 130
- 140
ENEC certification
In application at DEKRA
Warrenty
5 years
10/16
Manual Veko linear lighting system / IP65 / V04 / 2020-09-29 / Sensor (re-) placement
Ce manuel convient aux modèles suivants
2
Manuels Luminaire populaires d'autres marques

Emos
Emos CLASSIC ZY1431T Manuel utilisateur

Westinghouse
Westinghouse Outdoor Lighting Fixture Manuel utilisateur

Hedler
Hedler C 12 silent Manuel utilisateur

Blizzard Lighting
Blizzard Lighting Puck: CSI Manuel utilisateur

Energetic Lighting
Energetic Lighting ELYSL-5004 Series Manuel utilisateur

Lightmaxx
Lightmaxx Shaft 5R Manuel utilisateur

Cooper Lighting
Cooper Lighting Halo L3232E Manuel utilisateur

Stageline
Stageline ODW-2410RGBW Manuel utilisateur

Light Sky
Light Sky Tornado Series Manuel utilisateur

Lightolier
Lightolier Paralyte 2424 PLA2G9LS26U Manuel utilisateur

Lightolier
Lightolier Lytespan 83ED17S Manuel utilisateur

Lightolier
Lightolier Calculite CS8226 Manuel utilisateur