VAF instruments T-SENSE Manuel utilisateur

Technical Manual
Instructions for installation,
operation and maintenance
669
T-SENSE®
Optical Torque Measuring systems
and PEM4 stand alone
Publication nr
TIB-669-GB-1117
Supersedes
-

TABLE OF CONTENTS
1.PREFACE.................................................................................................................... 3
1.1General................................................................................................................... 3
1.2Symbols.................................................................................................................. 3
1.3Copyright................................................................................................................. 3
2.SYSTEM DESCRIPTION............................................................................................. 4
2.1PEM4 TOUCH SCREEN ........................................................................................ 4
2.2System security....................................................................................................... 4
3.TECHNICAL SPECIFICATIONS.................................................................................. 5
3.1PEM4 TOUCH SCREEN ........................................................................................ 5
4.SAFETY INSTRUCTIONS........................................................................................... 5
5.UNPACKING................................................................................................................ 5
6.INSTALLATION AND FIRST USE............................................................................... 5
6.1To record nameplate data....................................................................................... 7
6.2Installation diagram................................................................................................. 8
6.3Installation of the PEM4 touch screen .................................................................... 9
6.4Cable specifications.............................................................................................. 13
7.OPERATING PRINCIPLES........................................................................................ 14
7.1General................................................................................................................. 14
7.2Displayed parameter and engineering units ......................................................... 14
7.3Explanation of the parameters.............................................................................. 14
7.3.1Torque......................................................................................................... 14
7.3.2Shaft speed................................................................................................. 14
7.3.3Power.......................................................................................................... 14
7.3.4Thrust (option)............................................................................................. 14
7.4Operating instructions PEM4 touchscreen
............................................................ 15
7.4.1Operating menus......................................................................................... 15
7.5How to operate the touch screen.......................................................................... 15
7.5.1Home menu................................................................................................. 15
7.5.2Propulsion menu......................................................................................... 16
7.5.3Settings menu............................................................................................. 16
7.5.4Alarm screen............................................................................................... 18
7.6Method of calculations.......................................................................................... 19
8.MAINTENANCE......................................................................................................... 20
9.REPAIR...................................................................................................................... 20
10.TAKE OUT OF SERVICE..................................................................................... 20
11.REMOVAL AND STORAGE OF EQUIPMENT..................................................... 20
12.MALFUNCTION AND SEND FOR REPAIR ......................................................... 20
13.ENVIRONMENT ................................................................................................... 20
14.DISPOSAL............................................................................................................ 20
15.TROUBLE SHOOTING......................................................................................... 21
15.1PEM4 malfunction ............................................................................................. 21
15.2No torque signal ................................................................................................ 21
16.CERTIFICATES.................................................................................................... 21
16.1EMC classifications of the PEM4....................................................................... 21
17.DRAWINGS.......................................................................................................... 22
18.ABBREVIATIONS................................................................................................. 25

2
19.SPARE PARTS..................................................................................................... 25
20.WARRANTY CONDITIONS.................................................................................. 26

3
1. PREFACE
1.1 GENERAL
The PEM4 touch screen is a microprocessor based instrument, which is able to fulfil standard torque,
shaft speed and power calculations within narrow limits. Thrust and thrust/power calculations can be
performed when thrust measurements are available.
The T-Sense®torque sensor is the measuring instrument providing torque, speed and power as input
for the PEM4 touch screen. The TT-Sense®additionally provides thrust measurements as input. This
completely unique and compact total solution can be used for simple to complicated configurations.
Never use the equipment outside its specifications or beyond common engineering
practice nor use the equipment for other applications or make connections to other
equipment than explicitly described in the order acknowledgement and/or technical
manuals of VAF Instruments.
To ensure safe and correct installation and operation, read this manual completely before
installing the equipment and starting operations.
For any additional information contact:
VAF Instruments B.V. Tel. +31 78 618 3100
Vierlinghstraat 24, 3316 EL Dordrecht Fax +31 78 617 7068
The Netherlands Internet: www.vaf.nl
Or your local authorized VAF dealer.
Their addresses can be found on www.vaf.nl
1.2 SYMBOLS
The following symbols are used to call attention to specific types of information.
A warning to use caution! In some instances, personal injury or damage to the torque
sensor or control system may result if these instructions are not followed properly.
An explanation or information of interest.
1.3 COPYRIGHT
This Technical Manual is copyrighted with all rights reserved.
While every precaution has been taken in the preparation of this manual, no responsibility for errors or
omissions is assumed. Neither is any liability assumed for damages resulting from the use of the
information contained herein. Specifications can be changed without notice.

4
2. SYSTEM DESCRIPTION
2.1 PEM4 TOUCH SCREEN
The PEM4 touch screen is able to calculate several output data.
Functions, which can be performed with this PEM4 touch screen are:
Measurement and display of torque, shaft speed, power and thrust (optional).
Calculation of average shaft power, shaft speed and torque during the last 1, 4 and 24 hours.
Calculation of total energy and total revolutions including reset.
Calculation of average thrust/quotient when thrust measurement (optional) is provided.
Displaying of parameters.
The PEM4 touch screen can be installed in a control cabinet or control panel.
Remark:
Optional 4-20 mA analogue output can be integrated in the stator control box near the T-
Sense®torque sensor. Please read section 6.5 in TIB-661 for detailed information or read
TIB-664 section 6.5 in case of TT-Sense®torque/thrust sensor.
2.2 SYSTEM SECURITY
Besides checking the status of the torque measurement system the PEM4 system also checks itself
continuously for program and configuration data integrity, normal program flow and power supply
conditions. Alarm messages will be logged in a dedicated alarm screen.

5
3. TECHNICAL SPECIFICATIONS
3.1 PEM4 TOUCH SCREEN
Supply voltage 115-230 VAC to power supply unit
Dimensions 235 x 150 x 44 (w x h x d)
Cut out 217,6 x 128,6 mm (w x h)
Cut out depth 38 mm
Front panel thickness 7 mm
Connections RJ45 Ethernet connection on the back-bottom side of the panel
Temperature range -20ºC – 60ºC
Display Color TFT LCD, PCAPTouch screen 7,0” (1024 x 600 dots) with
adjustable LED backlight
Power consumption 8 W
Processor (CPU) i.MX 6 DualLite at 1 GHz, 2 GB DDR3 on board memory
Net weight 1,3 kg
Figure 1 – PEM4 touch screen
4. SAFETY INSTRUCTIONS
There are no special safety instructions for the equipment.
5. UNPACKING
Let the equipment acclimatize inside the closed box for at least one hour at the location where the
system will be installed.
When the equipment is taken out of the box, please leave the special protection supplied with the
equipment as long as possible in place to avoid any damage.
The special protection should be stored for the unlikely event the equipment has to be sent for repair.
Dispose of the packing material should be done according to the laws of the country where the
equipment is installed, or according to the rules that are applicable on the vessel.
Be careful when unpacking the electronic equipment. The content is fragile.
Do not press on the PEM2 touch screen.
6. INSTALLATION AND FIRST USE
The PEM4 touch screen will be delivered with the software and correct data settings installed. First
connect the Ethernet cables to the control box and the touch screen.
The wires for power supply should be connected at last.

7
Check if the inputs show any errors. If that is the case the connection(s) or connected equipment
should be checked and corrected.
6.1 TO RECORD NAMEPLATE DATA
This information is required when contacting the supplier for any reason.
Date of delivery: xx xx xxxx
Serial number: xxxx
Stator version: xxxx
Interface version: xxxx
Hull number: xxxx
Type: PEM4 touch screen
Above information can be found at the PEM4 info screen.

8
6.2 INSTALLATION DIAGRAM
The PEM4 touch screen can be connected to the stator control box as shown in Figure 2 and Figure 3.
The maximum number of touch screens, which can be connected by Ethernet connection is two.
Figure 2 – T-Sense®torque sensor connected to one PEM4 touch screen
Figure 3 – Example of T-Sense®torque sensor connected to two PEM4 touch screens
Remark:
When a TT-Sense®Thrust & Torque sensor is installed it can be connected in the same
way as above mentioned T-Sense®equipment.

9
6.3 INSTALLATION OF THE PEM4 TOUCH SCREEN
1. Install the PEM4 touch screen in a control cabinet or control panel in the ECR or on the bridge,
where it will be free as possible from moisture, large fluctuations of temperature and particularly of
vibration shock. Also influences such as large magnetic fields caused by transformers, relays or
electromagnets must be avoided.
2. All cable connections should be made using cables as specified in section 6.4.
3. Connect the RJ45 Ethernet from the stator control box and power supply to the backside bottom of
the PEM4 touch screen in accordance with Figure 4.
Figure 4 – ON/OFF switch and communication ports at backside bottom of PEM4 touch screen
4. Check for correct power supply and integrity of external wiring connections. Turn on power and
observe several readings, like torque, shaft speed, power etc.
Important notes
Never connect cable shields at both ends to ground, but at one end only, to avoid
earth loops.
To avoid interference on the signal cables, such cables must be installed as far as
possible from electric power cables used for power supply and stator.
Ensure that the ambient temperature at the PEM4 never exceeds 55°C.

10
5. Only applicable if an additional (second) touch screen is connected to the T-Sense®system.
Additional touch screens are connected to the system as described in Figure 5.
For the use of two PEM4 screens a Ethernet switch is necessary.
Check for correct power supply and integrity of external wiring connections. Turn on power and
observe several readings, like torque, shaft speed, power etc.
Figure 5 – Example of T-Sense®torque sensor connected to two PEM4 touch screens
Table des matières
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur