Thank you for purchasing this Unitrol SOFT
TOUCH system. It is designed to protect your
resistance welder operator from serious elec-
trode pinch point injury. Please let us know if
there are any questions or problems with the
installation or use of this product. You can con-
tact us:
By Phone:
Monday - Friday 9:00 - 5:00 CT: 847-480-0115.
By Email:
techsupport@unitrol-electronics.com
By Regular Mail:
Unitrol Electronics, Inc.
Technical Support
702 Landwehr Road
Northbrook, Illinois 60062

4

5
MODEL NUMBER AND OPTIONS AS CHECKED BELOW
SERIAL NUMBER:
CHECK MODEL
WELDER TYPE
AND
HARDWARE
RAM TYPE VALVE
VOLTAGE
9181-34WB/115 1Ø AC
INCLUDES A
SNUBBER
AND
2=MUFFLERS
HEAVY WEIGHT 115AC
9181-34YB/115 LIGHT WEIGHT, ROCKER ARM
9181-34WB/24DC HEAVY WEIGHT 24VDC
9181-34YB/24DC LIGHT WEIGHT, ROCKER ARM
9181-34WB/24AC HEAVY WEIGHT 24VAC
9181-34YB/24AC LIGHT WEIGHT, ROCKER ARM
9181-34WM/115
MFDC
(INVERTER)
INCLUDES
2=MUFFLERS
HEAVY WEIGHT 115VAC
9181-34YM/115 LIGHT WEIGHT, ROCKER ARM
9181-34WM/24DC HEAVY WEIGHT 24VDC
9181-34YM/24DC LIGHT WEIGHT, ROCKER ARM
9181-34WM/24AC HEAVY WEIGHT 24VAC
9181-34YM/24AC LIGHT WEIGHT, ROCKER ARM
OPTIONS
9181-34BPA
Timed bypass. Includes security lock selector switch, 2 = LED
indicator lights, faceplate. Closes electrodes under low force,
delays, and brings electrodes to welding force.
9181-34JA
Retract Kit. Includes HEAD DOWN proximity switch and
mounting bracket kit. May require additional field bracketry
to match welder
9181-34JB
Retract option without proximity switch. For use with weld-
ers that have separate RETRACT and WELD INITIATION
switches.
9181-34LSA
Limit Switch. Allows use of ram position or continuity. In-
cludes RAM POSITION proximity switch and mounting brack-
et kit. May require additional field bracketry to match weld-
er. Includes security lock selector switch, 2 = LED indicator
lights, faceplate
9181-34LSB
Limit Switch. Allows use of a ram position or continuity. In-
cludes security lock selector switch, 2 = LED indicator lights,
faceplate. Does NOT include a proximity switch or mounting
bracket kit. Use with customer-supplied PNP proximity
switch.
9181-34LSC
Limit Switch used as a redundancy with continuity. Always in
operation and not keylock selected. Includes RAM POSITON
proximity switch and mounting bracket kit. May require addi-
tional field bracketry to match welder. Can be turned off by
moving a jumper on the control board inside the locked cabi-
net.
9181-34FRL-1/2 ½” NPT Filter, regulator, lubricator with inter block for pilot
line. With air gauge. Not needed if existing regulator is good.
9181-34FRL-3/4 ¾” NPT Filter, regulator, lubricator with inter block for pilot
line. With air gauge. Not needed if existing regulator is good.

6
WARRANTY
Unitrol Electronics provides a 5-year limited warranty to cover all of this SOFT TOUCH sys-
tem. The warranty periods are determined using the date the new control was originally
shipped from Unitrol Electronics. All warranty coverage is FOB Northbrook. Illinois.
This warranty, except for exclusions shown herein covers the following items:
DURING YEAR #1: All parts (exclusive of fuses) that fail due to manufacturing defects.
Necessary labor to repair control that has failed due to manufacturing defects.
DURING YEAR #2: 80% cost of all parts (exclusive of fuses).
80% cost of necessary labor to repair control that has failed due to manufacturing defects.
DURING YEAR #3: 60% cost of all parts (exclusive of fuses).
60% cost of necessary labor to repair control that has failed due to manufacturing defects.
DURING YEAR #4: 40% cost of all parts (exclusive of fuses).
40% cost of necessary labor to repair control that has failed due to manufacturing defects.
DURING YEAR #5:
20% cost of all parts (exclusive of fuses).
20% cost of necessary labor to repair control that has failed due to manufacturing defects.
EXCLUSIONS TO WARRANTY
Any expense involved with repair of control by other than Unitrol Electronics personnel that
has not been authorized in advance and in writing by an officer of Unitrol Electronics.
All costs for freight, to and from Unitrol Electronics, are excluded from this warranty
All field service labor, travel expense, and field living expenses associated with field service
are excluded from this warranty.
No coverage, parts or labor, is offered for components that have failed on control not being
used as specified in Unitrol Electronics published literature, technical sheets, and this direction
book.
No warranty coverage will be made on controls that are being used contrary to specifications,
that were mechanically or electronically altered by customer or installer, or that were physical-
ly damaged after shipment from Unitrol Electronics.
Damages to a control by lightning, flood, or mechanical damage are excluded from this war-
ranty.
Unitrol Electronics assumes no liability for damage to other equipment or injury to personnel
due to a failure in the Unitrol Electronics control.
Unitrol Electronics shall not be responsible for any consequential damages of whatever kind.
Expenses involving alteration or installation of a Unitrol Electronics control are not covered in
this warranty.
NO OTHER UNITROL ELECTRONICS INC. WARRANTY, WRITTEN OR
IMPLIED, COVERS THIS CONTROL UNLESS IN WRITING AND SIGNED
BY AN OFFICER OF UNITROL ELECTRONICS, INC. PRIOR TO SHIP-
MENT OF PRODUCT.

7
1VERIFY YOUR SOFT TOUCH SENSOR BOARD IS CORRECT
2HOW SYSTEM OPERATES
3INSTALLATION, 9181-34W HEAVY WEIGHT SERIES
4INSTALLATION, 9181-34Y LIGHT WEIGHT SERIES
5WIRING CONTROL: CONNECTING SIGNAL PICKUP WIRES
6CONNECTING THE SNUBBER
6CONNECTING CONTROL CABLE
7CONTROL CABLE WIRING CHART
8ELECTRICAL HOOKUP, 9181-34WB/115, 9181/34YB/115
9ELECTRICAL HOOKUP, 9181-34WB/24DC,9181/34YB/24DC
10 ELECTRICAL HOOKUP, 9181-34WB/24AC,9181/34YB/24AC
11 ELECTRICAL HOOKUP, 9181-34WM/115, 9181/34YM/115
12 ELECTRICAL HOOKUP,9181-34WM/24DC,9181/34YM/24DC
13 ELECTRICAL HOOKUP,9181-34WM/24AC,9181/34YM/24AC
14 RETRACT OPTION 9181-34JA
16 RETRACT OPTION 9181-34JB
18 TIMED BYPASS OPTION 9181-34BP
19 PNEUMATIC HOOKUP, 9181-34Y LIGHT WEIGHT
20 PNEUMATIC HOOKUP, 9181-34W HEAVY WEIGHT
21 ADJUSTING SOFT TOUCH VALVES
22 SETTING MAXIMUM DETECT TIME SWITCHES
22 TESTING ELECTRONIC SYSTEM
23 STARTUP PROCEDURE
24 TESTING ELECTRODE CLOSING FORCE
25 TROUBLE SHOOTING CHART
26 LED INDICATOR LIGHTS
TABLE OF CONTENTS

8

1
VERIFY YOUR SOFT TOUCH SENSOR BOARD IS CORRECT
The SOFT TOUCH sensor board can be configured in several
ways. Before turning power on, check to be sure that the
mode and valve voltage matches your welder.
1. TYPE OF WELDING CONTROL. This board can be set to
operate either a 1ØAC welder or an MFDC (inverter) welder.
This is done by pushing the three switches on the lower left
corner to a position to match your welding control.
FOR 1ØAC WELDERS FOR MFDC (inverter) WELDERS
2. SOLENOID VALVE VOLTAGE. Be sure that the two tall
relays, K2 and K3, show the same voltage on the top printing
as the solenoid voltage of your welding control.
FOR 115VAC FOR 24VDC
SOLENOID VALVES SOLENOID VALVES

2
HOW THE SYSTEM OPERATES
When the solenoid valve output from the welding control goes HIGH,
this voltage goes to the 9280-TS6 SOFT TOUCH detecon board, terminal
#9.
The output terminal #11 (SVL) goes HIGH to turn on solenoid valve SVL.
For 9181-34WB systems, this closes the welding electrodes under gravi-
ty force with low force bucking pressure (ADVANCE) acng on the under-
side of the cylinder piston to counterbalance part of the ram dead
weight.
For 9181-34YB systems, this closes the welding electrodes under low
force using low air pressure on the forward port of the welder cylinder.
The 9280-TS6 board checks input at terminals #4 and #5 to see if the
voltage signal drops a minimum value indicang that the electrodes have
made contact on a conducng material (connuity detected).
If this contact is NOT sensed within the maximum me seng on
the board’s DIPswitches, the output terminal #11 (SVL) will go
LOW and drop out solenoid valve SVL to open the electrodes.
If this contact IS sensed within the maximum me seng:
Terminal #11 (SVL) will connue to be HIGH
Terminal #13 (SVH) will go HIGH
Solenoid valve SVH will be turned ON to start high electrode
pressure, and relay K4 on this board will close to start the weld-
ing sequence
The contact across terminals #6 and #7 on the TS2 board close
to tell the welding control to start the welding sequence.
SOFT TOUCH PINCH POINT
PROTECTION SYSTEM
FOR INSTALLATION ON NON-UNITROL
1Ø AC and MFDC WELDING CONTROLS
Ce manuel convient aux modèles suivants
11
Table des matières
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur