Unimotion STDF PD Manuel utilisateur

Manual
Closed Loop Stepping System Manual
STDF PD - Pulse-direction


3/24
TABLE OF CONTENTS
1Before operation 4
1.1 Precautions ............................................................................................................ 4
1.1.1 Put the Safety First ..................................................................................................... 4
1.1.2 Operation..................................................................................................................... 5
1.1.3 Check and Repair ........................................................................................................ 5
2Drive Specification and Dimension 6
2.1 Specifications of Drive............................................................................................ 6
2.2 Model naming......................................................................................................... 7
2.3 Product dimensions................................................................................................ 7
3Installation 8
3.1 Precautions of installation ...................................................................................... 8
3.2 Appearance and part name ..................................................................................... 8
4Brake Operation Timing Chart 9
5Settings and Operation 10
5.1 Drive Status LED ................................................................................................... 10
5.2 Pulse Input Setting Switch (SW1.1) ....................................................................... 11
5.3 Rotational Direction Setting Switch (SW1.2) .......................................................... 12
5.4 Resolution Setting Switch (SW3)........................................................................... 12
5.5 Position Controller Gain Setting Switch (SW2)....................................................... 13
5.6 In-Position Value Setting Switch (SW4)................................................................. 14
5.7 Encoder Connector (CN2) ..................................................................................... 15
5.8 Input/Output Signal Connector (CN1) .................................................................... 15
5.9 Motor Connector (CN3)......................................................................................... 16
5.10 Power Connector (CN4)..................................................................................... 16
6System Configuration 17
6.1 External Wiring Diagram........................................................................................ 18
7Control Signal Input/Output Description 19
7.1 Input Signal .......................................................................................................... 19
7.2 CW, CCW Input ..................................................................................................... 19
7.3 Servo On/Off Input................................................................................................ 20
7.4 Alarm Reset Input ................................................................................................. 20
7.5 Output signal ........................................................................................................ 21
7.6 Alarm Output ........................................................................................................ 21
7.7 In-Position Output ................................................................................................ 22
7.8 Encoder Signal Output .......................................................................................... 22

4/24
1 BEFORE OPERATION
Thank you for your purchasing the STDF PD drive.
STDF PD is an all-in-one unit. For the high-speed and high-precision drive of a stepping motor,
STDF PD is a unique drive that adopts a new control scheme owing to an onboard
high-performance 32-bit MCU.
This manual describes handling, maintenance, repair, diagnosis and troubleshooting of the
STDF PD.
Before operating with STDF PD, thoroughly read this manual.
After reading the manual, keep the manual near the STDF PD so that any user can read it
whenever required.
1.1 Precautions
1.1.1 Put the Safety First
Before installation, operation and repairing the STDF PD, thoroughly read the manual and
fully understand the contents. Before operating the STDF PD please, understand the
mechanical characteristics of the STDF PD and related safety information and precautions.
This manual divides safety precautions into Attention and Warning.
Attention
If the user does not properly handle the product, the user may seriously or slightly be injured
and damages may occur in the machine.
Warning
If the user does not properly handle the product, a dangerous situation (such as an electric
shock) may occur resulting in deaths or serious injuries.
Although precaution is only an Attention, a serious result could be caused depending on the
situation.
Follow safety precautions.

5/24
1.1.2 Operation
Attention
If a protection function (alarm) occurs, firstly remove its cause and then release (alarm reset)
the protection function. If you operate continuously without removing its cause, the machine
may get damaged or the user may get injured.
Do not make Motor Free and make input signal to ON during operation. The motor will stop
and the stop current will become zero. The machine may get damaged or the user may get
injured.
Make all input signals OFF before supply input voltage to STDF PD. The machine may get
damaged or the user may get injured by motor operation.
All parameter values are set by default factory setting value. Change this value after reading
this manual thoroughly. Otherwise, the machine may get damaged or other kinds of accidents
may occur.
1.1.3 Check and Repair
Attention
Stop to supply power to the main circuit and wait for a while before checking or repairing the
STDF PD. Electricity remaining in the capacitor may cause danger.
Do not change cabling while power is being supplied. Otherwise, the user may get injured or
the product may get damaged.
Do not reconstruct the STDF PD. Otherwise, an electric shock may occur or the reconstructed
product can not get After-Service.

6/24
2 DRIVE SPECIFICATION AND DIMENSION
2.1 Specifications of Drive
Table 2-1: Drive specifications.
Input Voltage
24 V DC +/- 10%
Control Method
Closed loop control with 32-bit MCU
Current Consuption
Max 500 mA (Except the motor current)
Operating Condition
Ambient temperature
In Use: 0 ∼50 °C
In Storage: –20 ∼70 °C
Humidity
In Use: 35 –85 % RH (Non–
condensing)
In Storage: 10 –90 % RH (Non–
condensing)
Vib. Resist.
0.5 G
Function
Rotation Speed
0 ∼3000
Resolution [ppr]
500, 1000, 1600, 2000, 3600, 5000,
6400, 7200, 10000 (Selectable with
the rotary switch)1
Max. Input Pulse Frequency
500 kHz (Duty 50 %)
Protection Functions
Over Current Error, Over Speed
Error, Position Tracking Error,
Encoder Connect Error, In-Position
Error, System Error, ROM Error,
Position Overflow Error
LED Display
Power status, In-Position status,
Servo On status, Alarm status
In-Position Selection
0 –F (Selectable with Rotary
switch)
Position Gain Selection
0 –F (Selectable with Rotary
switch)
Pulse Input Method
1 –Pulse/2 –Pulse (Selectable
with DIP switch)
Rotational Direction
CW/CCW (Selectable with DIP
switch)
Speed/Position Control
Command
Pulse-Train Input
I/O Signal
Input Signals
Position Command Pulse, Servo
On/Off, Alarm Reset (Photocoupler
Input)
Output Signals
In-Position, Alarm (Photocoupler
Input) Encoder Signal (A+, A-, B+, B-,
Z+, Z-, 26C31 of Equivalent) (Line
Driver Output), Brake
1 When selected resolution is more than encoders resolution, motor shall operate by microstep between pulses.

7/24
2.2 Model naming
Figure 2-1: Model naming.
2.3 Product dimensions
Figure 2-2: Dimensions of the STDF PD drive.

8/24
3 INSTALLATION
3.1 Precautions of installation
1. STDF PD is designed for indoor use only.
2. The ambient temperature of the room should be 0 °C ∼50 °C.
3. If the temperature of the product case is higher than 50 °C, radiate heat of the
outside to cool down.
4. Do not install STDF PD under direct rays, near magnetic or radioactive objects.
5. If you set more than 2 drives, you must set over 20 mm vertically and over 50 mm
horizontally as shown below.
Figure 3-1: Installation dimensions for 2 or more drives.
3.2 Appearance and part name
Figure 3-2: Appearance of the STDF PD drive.

9/24
4 BRAKE OPERATION TIMING CHART
STDF PD controls Brake by Drive automatically.
Please refer to below Timing Chart when Brake is controlled by the upper controller other
than using STDF PD Brake control. Otherwise, Drive malfunctioning and loads can be fall
down.
Also, please do not operate Brake while motor operation to prevent damage.
Figure 4-1: Brake operation timing chart.

10/24
5 SETTINGS AND OPERATION
5.1 Drive Status LED
Table 5-1: Drive status LED indication.
Indication
Color
Function
ON/OFF Condition
PWR
Green
Power indication
LED is turned On
when power is
applied
INP
Yellow
Complete
Positioning Motion
Lights On when
Positioning error
reaches within the
preset pulse
selected by rotary
switch
SON
Orange
Servo On/Off
Indication
Servo On: Lights On
Servo Off: Lights Off
ALM
Red
Alarm Indication
Flash when
protection function
is activated
(Identifiable which
protection mode is
activated by
counting the
blinking times)
Figure 5-1: Alarm LED flashing cycle
Table des matières
Autres manuels Unimotion Entraînement CC
Manuels Entraînement CC populaires d'autres marques

Vincent Associates
Vincent Associates UNIBLITZ ED12DSS Manuel utilisateur

EKSMA OPTICS
EKSMA OPTICS DQ-100-4 Manuel de la liste des pièces

Chamberlain Garog
Chamberlain Garog D Series Manuel utilisateur

Parker
Parker PDS Series Manuel utilisateur

Festo
Festo DGC G Series Guide de configuration

Binks
Binks QS-5012-1-CE Manuel utilisateur