Unika DSP-1000 Manuel utilisateur

DSP Audio Processor
Operation Manual
Control Software and Device Front Panel Operation
Unika DSP-1000 Unika DSP-1001 Unika DSP- 428


DSP Audio Processor
● Index
Tools .................................................................................................................... 3
Unit Window:Main Panel ................................................................................
5
Main Setup Screen Functions ..........................................................................
8
Input Channel Settings Screen
......................................................................
10
Crossover Settings Window
.........................................................................
13
Output Channel Settings Window
................................................................
15
Access Control and Locking ..........................................................................
18
Firmware Update Process ...............................................................................
23
Front Panel Control Features .........................................................................
24
Specication ....................................................................................................
36
DSPControl Download
WINDOWS 32bit : https://goo.gl/mhQ0hH
WINDOWS 64bit : https://goo.gl/OaahBS
MAC OS X : https://goo.gl/PamXJ8

1
DSP Audio Processor
Introduction
Getting Started
Installation and Setup
The UNIKA DSP speaker management processors can be operated from their respective front
panels or control panels to a varying degree, depending on model. However, for maximum
exibility, remote operation from a Windows PC as well as from an Apple computer running OSX
is also possible; for this remote functionality, the device must be connected via a wired Ethernet
or a USB connection to the same network as the control computer. The control computer can be
connected to the network wired or through Wi-Fi.
● It is recommended that a router with DHCP server is connected to the network so that it assigns
the unit an IP address.
● When the controller is connected to the network, you can check or set its IP address via the unit
window under Hardware - > Congure - > Network Settings → IP address.
The default setting is DHCP (Auto IP).
● If Fixed IP address has been set, and this is no longer known or been forgotten, it can be
requested via the display on the device. Press the menu button four times and turn the encoder
wheel to the right three times to display the IP address.
● Note: you cannot connect the unit to the network through the USB or Ethernet at the same time.
You can only control the unit from one platform at the same time – if you switch from one
platform to another, you MUST shut down the control software at the previous platform rst.
● Local connectivity of the device to the control computer from a front-panel USB connector is also
possible to download initial settings or as a fallback in case of network failure.
● This Software Manual explains the remote setup and operation of the system through a network.
The operation is basically same for all platforms; where differences exist they will be noted.
● Download and install the latest software from the UNIKA website. Note that for a Windows
computer, there are separate applications for Windows 32 bit and 64 bit.
http://www.unika.com.tw
● The software consists of a network window that list all known UNIKA DSP devices on the local
network, and one or more unit windows for settings of a device. In the following sections we will
discuss the Unika DSPControl program for Windows.
● The mac version works very similar to the Windows version.
The mac menu bar is different from Windows for most program, the same differences are
present with DSPControl.

2
DSP Audio Processor
Unika DSPControl
Figure 1: DSPControl network panel
Figure 2: Tools menu items
● The Windows Unika DSPControl Network window is shown in Figure 1: DSPControl network
panel. During installation your rewall setting are congured to allow communication over the
network.
● Switch on the DSP and launch the DSPControl software. It will show the devices found on the
network together with their mac address and IP address, similar to Figure 1.
● Note: you can control the unit from only one PC at the same time. If you want to switch control
from one to the other, shut down the Unika DSPControl software on the previous control platform
rst.
● The ‘>’ icon at the right side may be either > or >. When >, the unit is on line and can be
activated by clicking the >.
The main purpose of the control app is to select a particular unit for manipulation and/or to group
several units in a Group.
The available Tools commands are shown in Figure 2: Tools menu items.

3
DSP Audio Processor
1. Tools
● 1.1 Tools | Set Software Password
Allows you to set up a password to access the graphical DSP software unit window. The
DSPControl software has a separate, extensive system of operation modes.
Note: you can modify the Unit Name in the Unika- DSPControl program slot for the connected
unit by just typing a new Name.
● 1.2 Tools / New Group
This command allows you to combine several on- line units into a named group. The group will
be shown in the Control screen, see Figure 3.
Clicking the cross icon on the right deletes the
Group; clicking the blue tool icon opens a screen
where you can select the members of the Group;
you will be able to select any unit which is on-line
to become a member of the group.
A further selection from this screen opens a
dialog where you can specify which parameter,
for which setting and for which channel you wish
to link within the Group.
For instance, you can link only gain, or gain and
PEQ settings for Input & Output channels.
An example Group setting screen is shown in
Figure 4.
Figure 3: network window showing a named Group (Cluster 01) consisting
of two units
Figure 4: Sample selecting dialog box
showing
some linked items for a Group

4
DSP Audio Processor
● 1.3 Tools / Enter Demo Mode
Allows you to exercise the functionality of an Unika DSP unit without hardware present for
training and familiarization purposes.
● 1.4 Tools / Disable / Enable Updates
When set to Enable Updates, there will be an indication when rmware updates for the unit will
be available. This is shown on the right edge of the unit identication in the control program with
a ‘rotary’ icon, see Figure 5. The icon turns yellow color when updates are available. Clicking
the icon will initiate the update.
This is a ‘brute force’ update which will also restore the unit after a crash or other unrecoverable
situation. All presets and other settings will be lost however.
Clicking the green > symbol at the right of the connected unit info line in the Unika DSPControl
window will load the software for the unit. At this point, the software will go through a
synchronization cycle and, if a Personal Identication Number (PIN) was dened before, will ask
for the PIN.
The Main graphical interface screen will come up similar to Figure 6; this is the opening screen of
the actual application controlling the settings of the unit.
● 1.5 Other Settings
● 1.5.1 Power-On Preset
In the menu item Hardware - > Congure - > Power On Preset, a preset can be selected, which
is automatically loaded when the device starts.
● 1.5.2 Read Only Preset Range
When you are logged on as Developer or higher, you can block a certain preset range from
being altered.
In Hardware - > Congure - > Read-Only Preset. If the value is, for example, set to 10, the rst
10 memory locations in the preset list for User and Admin mode are read only and the user
cannot save presets to those locations.
Figure 5: rotary’ icon yellow color at right indicates rmware update for this
unit is available

5
DSP Audio Processor
2. Unit Window: Main Panel
Figure 6: unit window
● 2.1 Unit Window Menu
Figure 6: unit window shows the unit window from which all setup screens and options can be
reached. Clicking the exit cross will close the software but leave the network Control program
running.
● 2.2 File Commands
● 2.2.1 File / Open and File / Save
Presets are the snapshot of all settings for a particular conguration. With these commands you
can save a preset, and reload it at a later time. In addition it offers the choice to use the .preset
le format or the .txt format. Text les are a way to archive settings for documentation purpose.
● 2.2.2 File / Backup presets and File / Restore presets
These commands operate similarly to Save and Open, but will save all presets in the unit in one
directory, or load all presets from a directory.
● 2.2.3 File Quit – self-explanatory

6
DSP Audio Processor
● 2.3.1 Hardware / Enter Password
The unit has three access levels plus locked. Entering the right access level password unlocks
that access level. Please see password protection, access control & locking.
● 2.3.2 Hardware / Congure
The Congure menu item opens an additional screen where several options are presented. However,
the options shown will depend on the access level currently in force – to be discussed.
● 2.3.3 Hardware / Congure / Power On Preset
Allows you to select a preset that will be automatically loaded at power-on;however any
changes to this preset will not be carried over to the next power-on cycle unless you have
saved the new setting, i.e. it will revert to the saved preset.
● 2.3 Hardware Commands
The Hardware menu offers several functions as shown in Figure 7: unit panel Hardware menu
items.
Figure 7: unit panel Hardware menu items

7
DSP Audio Processor
● 2.3.4 Hardware / Lock Unit
Clicking this menu item will lock the unit. When locked, the unit window shows input levels but
no controls or other settings, and nothing can be changed, as shown in Figure 8: detail of unit
panel in locked state.
An attempt to lock the unit will generate a warning that unlocking will only be possible with a valid
password. The actual operation of this function depends on the access level as described later.
● 2.3.5 Hardware / Go to Standby
Will place the unit in Standby. In this state, outputs are disabled but all settings can still be
manipulated.
● 2.3.6 Hardware / Set PIN
Clicking this option allows you to enter a 4-digit PIN number. When this is set, you will need
to enter the PIN number at any time you connect to the unit. Note: the PIN control can be
switched off by setting the PIN to 0000.
Figure 8: detail of unit panel in locked state.
Ce manuel convient aux modèles suivants
2
Table des matières

















