Unicont DTS-100 Manuel utilisateur



User manual Rev 1.3
3
Contents
1. Introduction ......................................................................................................................4
2. System specifications...................................................................................................5
2.1.. General overview ..........................................................................................5
2.2. Maximum capacity ........................................................................................6
2.3. Electrical specifications ..............................................................................6
2.4. Mechanical specifications ..........................................................................6
2.5. Dimensions ......................................................................................................6
2.6. Environment limitations ..............................................................................6
2.7. Cable requirements ......................................................................................7
2.8. Power supply requirements ......................................................................7
2.9. Key telephone parameters ........................................................................7
2.10. Phones ............................................................................................................8
3. Mounting and wiring......................................................................................................10
3.1. Site requirements .........................................................................................10
3.2. System unpacking .........................................................................................12
3.3. Examination before mounting ..................................................................12
3.4. Stations and trunk lines wiring ................................................................12
3.5. External Public Address System
and external music source wiring ....................................................................14
3.6. Power supply wiring .....................................................................................14
3.7. Turning ON the system ...............................................................................14
3.8. System programming .................................................................................14
4. Equipment supplied .......................................................................................................17
5. Transportation and storage ......................................................................................18
6. Warranty ...........................................................................................................................19
7. Purchase information ...................................................................................................20
8. Acceptance report ........................................................................................................21
9. Installation report ...........................................................................................................22

UNICONT DTS-100
4
1. Introduction
All technical characteristics, specifications, commissioning procedure and
maintenance of UNICONT DTS-100 key telephone system are given in the
following manual. This information is intended for the technical specialists,
performing mounting and testing of the system.
Fig 1. System Connection Diagram

User manual Rev 1.3
5
2. System specifications
2.1. General overview
UNICONT DTS-100 marine telephone system was specially designed for
applications at industrial facilities, marine vessels and river boats. System
design is adapted to harmful effects of the ambient environment. Key telephone
and carrier sockets are suspended on the anti-vibrating absorbers in the sealed
case (IP 53 protection). The boards are processed with corrosion-resistant
coating in order to protect from harmful impact of increased humidity. Locks
with latches are installed on the case door in order to prevent sticking of the
door.
UNICONT DTS-100 is a full-featured PBX telephone system that includes
everything you need to sound big. It is basically a small communication
system with big-company features usually not found from other similar PBXs.
Outstanding feature in UNICONT DTS-100 is the ability to add digital feature
into simple analog line without additional cost or a need of special equipment.
Essential business services such as Caller ID, SMS and voice/fax tone detection,
voice mail, auto attendant, conferencing capability, and LAN interface for
Ethernet connectivity and much more are already available as part of standard
features.
Moreover, ability to cut-down your communications cost (phone bill) by up to
60% by utilizing Call cost control/monitoring as well as sophisticated Least
Cost Routing (LCR) capability are already built in as part of value-added features
not offered by other competitors.
Fig 2. DTS-100 reference designator
A powerful ARM7 microprocessor digitally controls all speech paths and system
functions. The operating program with default settings is stored in non-volatile
ROM. User’s data is protected by a rechargeable Ni-Cd battery for up to seven
day’s continuous loss of system power. After resumption of system supply, the
battery is recharging automatically.

UNICONT DTS-100
6
On the whole, the system which consists of key telephone, extension boards and
regular phones, represents a contemporary, flexible and convenient telephone
system.
2.2. Maximum capacity
Maximum number stations 47+2*
Maximum number of trunk lines 12
Public address system ports 1
External music source port 1
* - 48 of internal stations is present, only in case of 1 digital and 47 analog or
digital phones are connected to DTS-100.
2.3. Electrical specifications
Input voltage 220-240 VAC , 50Hz
Power consumption 91W (max)
Ring generator 80 VRMS, 25Hz
Battery backup supply 24 VDC
2.4. Mechanical specifications
Case color Gray
Protection IP 53
Door locking Latch locks 2 pcs.
Marine vibration absorber 4 pcs. (АКСС-25М type)
2.5. Dimensions
Case dimensions 760х600х210 mm
Weight 43 kg
2.6. Environment limitations
Operating temperatures 0 ~ 40 °С
Operating humidity 10 ~ 90%

User manual Rev 1.3
7
2.7. Cable requirements
Equipment Cable AWG Max distance
Digital keysets 2 twisted pairs 24 (0,22 mm2) 400 m
Single line station 1 twisted pair 24 (0,22 mm2) 1 km
Add-on modules 1 twisted pair 24 (0,22 mm2) 400 m
Door phone 2 twisted pairs 24 (0,22 mm2) 100 m
2.8. Power supply requirements
220-240VAC, 50Hz input voltage is required for power supply of the key
telephone system. In case of input voltage significant drop, the system
immediately switches to backup power supply, 24VDC. To supply 24 VDC, use
four 6V or 12V batteries connected in series, with battery capacity of 6 ~ 40
ampere-hours.
2.9. Key telephone parameters
Key telephone system are advanced, user-friendly digital keysets, offering the
convenience of 3 soft buttons and a navigation key.
Features:
-.Trendy and Stylish LDP Family design
-.Multi Level 3 Line LCD (3 x 24)
-.24 Flexible buttons with dual-color LED’s
-.Call Log Feature
-.Wall Mountable (Bracket Optional)

UNICONT DTS-100
8
Fig 3. Physical configuration of key telephone of DTS-100
2.10. Phones
The system is able to dial by means of either tone or pulse phones. It should
be taken into consideration, that only tone dialing phones are suitable for
programming the majority of functions. Pulse phones don’t have access to the
system functions and parameter changing.
Housing and overall dimensions of additional phones P-2350, that is also
available upon request.

User manual Rev 1.3
9
Fig 4. Physical configuration and overall dimensions of Р-2350

UNICONT DTS-100
10
3. Mounting and wiring
This chapter shortly describes how to mount and wire UNICONT
DTS-100 system. It is recommended to read this chapter thoroughly
before mounting the system.
3.1. Site requirements
When planning the installation of the UNICONT DTS-100 system, choose a site
that meets the following requirements:
- Select a location that minimizes cable lengths.
- The equipment should not be exposed corrosive fumes, dust, or strong
magnetic fields such as those generated by motors and copying machines.
- Select a location for the system that has enough space for ventilation.
- The equipment should not be exposed to direct sunlight. The equipment
must be located in an environment that will maintain a temperature range
of 0 ~ 40°С and a humidity range of 10% ~ 90% non-condensing. The
location should have adequate lighting and ventilation, and should be dry and
clean.
Overall and mounting dimensions of the case are given at Fig 5
Table des matières