UL LA618 Series Manuel utilisateur

LA618 SUSPENDED
INSTALLATION INSTRUCTIONS
www.ullighting.net | 718.726.7500U.L. Lighting Fixtures Corp.
Specifications and data subject to change without notice. Consult factory when critical.
Consult factory for additional configurations and options not listed or shown.
Visit our website for the most current data
Rev. 05/2017
Page 1 of 4
GENERAL SAFETY INFORMATION
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts,
cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box and
all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general
precautions.
Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed
electrician.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
DO NOT INSTALL DAMAGED PRODUCT!
This fixture is intended to be connected to a properly installed and grounded UL listed junction box.
Suitable for Dry or Damp locations
WARNING: RISK OF ELECTRICAL SHOCK
Turn o electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
Turn o the power when you perform any maintenance.
Verify that supply voltage is correct by comparing it with the luminaire label information.
Make all electrical and grounded connections in accordance with the National Electrical Code and any
applicable local code requirements.
All wiring connections should be capped with UL approved wire connectors.
CAUTION: RISK OF INJURY
Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or
performing maintenance.
Avoid direct eye exposure to the light source while it is on.
Account for small parts and destroy packing material, as these may be hazardous to children.
CAUTION: RISK OF FIRE
Keep combustible and other materials that can burn away from luminaire and lamp/lens.
MIN 90°C SUPPLY CONDUCTORS.
SAVE THESE INSTRUCTIONS
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Each luminaire
is to be used with inside driver kit. Wiring to be performed by qualified electrician only.
APPLIES TO MODELS: LA618-2, LA618-4, LA618-5

SUSPENDED INSTALLATION
Step 1: Accessories
Step 2: Drill hole in the ceiling, push the rubber plug into the ceiling, fix the fixing head 2 in the ceiling with 4X30PA screw.
Step 3: A. Suspended method on the left: thread the square-head screw through fixing hole of safety rope, clamp and
8-figure buckle,and fixed with sewing machine
B. Suspended method on the right: thread the square-head screw through fixing hole of safety rope,clamp, and
fixed with sewing machine.
Step 4: A. Suspended method on the left: thread the power wire through 8-figure buckle fixed on the left, then install the
whole set of fixing clip on the lamp;
B. Suspended method on the right install the clip on the lamp.
Step 5: Fix the fixing head 1 with fixing head 2 tightly, and adjust suspended rope with sewing machine to
balance the lamp, finally connect input wire of lamp.
L
N
D+
D-
GND
L
N
D+
D-
GND
G
K
L
FH
I
J
A
B
C
D
E
ITEM
A. LA618 LAMP BODY
B. SQUARE-HEAD SCREW
C. SAFETY ROPE
D. CLIP
E. SEWING MACHINE
F. SUSPENDED ROPE
G. FIXING HEAD 1
H. 4X30PA SCREW
I. FIXING HEAD 2
J. RUBBER PLUG
K. 8 FIGURE BUCKLE
L. DOUBLING CLAMP
QTY.
1
2
4
2
2
2
2
2
2
2
1
4
STEP 1
STEP 4
STEP 2 STEP 3
STEP 5
LA618 SUSPENDED
INSTALLATION INSTRUCTIONS
www.ullighting.net | 718.726.7500U.L. Lighting Fixtures Corp.
Specifications and data subject to change without notice. Consult factory when critical.
Consult factory for additional configurations and options not listed or shown.
Visit our website for the most current data
Rev. 05/2017
Page 2 of 4
APPLIES TO MODELS
LA618-2, LA618-4, LA618-5

CEILING SURFACE MOUNT INSTALLATION
Step 1: Accessories
Step 2: Plan hole distance, and drill 4 holes of 3.0mm φ and 1 hole of 10.0mm φ.
Step 3: Fasten clip and elevated parts of clip with screws.
Step 4: Fasten assembled clip kits in plastic rubber of ceiling with screws.
Step 5: Thread AC input wire of lamp through another side of ceiling.
Step 6: Thread screw through fixing hole of safety hole, then fasten it with clips kits.
Step 7: According above detailed figure, first snap one side on clip kits, then rotate it to install on another
side of clip kits.
Step 8: Connect AC according mark on the input wire, then illuminate lamp, installation finish.
A
B
C
D
FINAL INSTALLATION
E
F
G
ITEM
A. LA618 LAMP BODY
B. SCREW
C. SAFETY ROPE
D. CLIP
E. SCREW
F. ELEVATED PART OF CLIP
G. RUBBER PLUG
QTY.
1
6
2
2
2
2
4
STEP 2 STEP 3 STEP 4
STEP 5
STEP 8
STEP 6 STEP 7
STEP 1
L [BROWN]
N [BLUE]
GND [YELLOW]
DIM+ [GREY]
DIM- [BLACK]
L [BROWN]
N [BLUE]
GND [YELLOW]
DIM+ [GREY]
DIM- [BLACK]
LA618 CEILING SURFACE MONT
INSTALLATION INSTRUCTIONS
www.ullighting.net | 718.726.7500U.L. Lighting Fixtures Corp.
Specifications and data subject to change without notice. Consult factory when critical.
Consult factory for additional configurations and options not listed or shown.
Visit our website for the most current data
Rev. 05/2017
Page 3 of 4
APPLIES TO MODELS
LA618-2, LA618-4, LA618-5

CONTINUOUS RUN INSTALLATION
Step 1: Accessories
Step 2: Snap AC input wire of lamp into U-Shape notch of connected section, then align fixing hole of connected section
to fixing hole on lamp, finally fasten connected section and lamp with screws.
Step 3: Align fixing hole of other side to fixing hole of lamp tail, then fasten connection section and lamp.
Step 4: Installation finish.
AC 100-277V
AC 100-277V
AC 100-277V
AC 100-277V
AC 100-277V
AC 100-277V
AC 100-277V
AC 100-277V
AC 100-277V
a
b
c
ITEM
A. LA618 LAMP BODY
QTY.
1
ITEM
B. CONNECTED SECTIONS (N-1)
QTY.
1
ITEM
C. SCREW (N-1)
QTY.
8
STEP 1
STEP 2
STEP 3
STEP 4
LA618 CONTINUOUS RUN
INSTALLATION INSTRUCTIONS
www.ullighting.net | 718.726.7500U.L. Lighting Fixtures Corp.
Specifications and data subject to change without notice. Consult factory when critical.
Consult factory for additional configurations and options not listed or shown.
Visit our website for the most current data
Rev. 05/2017
Page 4 of 4
APPLIES TO MODELS
LA618-2, LA618-4, LA618-5
Ce manuel convient aux modèles suivants
3
Table des matières
Manuels Luminaire populaires d'autres marques

Emos
Emos CLASSIC ZY1431T Manuel utilisateur

Westinghouse
Westinghouse Outdoor Lighting Fixture Manuel utilisateur

Hedler
Hedler C 12 silent Manuel utilisateur

Blizzard Lighting
Blizzard Lighting Puck: CSI Manuel utilisateur

Energetic Lighting
Energetic Lighting ELYSL-5004 Series Manuel utilisateur

Lightmaxx
Lightmaxx Shaft 5R Manuel utilisateur

Cooper Lighting
Cooper Lighting Halo L3232E Manuel utilisateur

Stageline
Stageline ODW-2410RGBW Manuel utilisateur

Light Sky
Light Sky Tornado Series Manuel utilisateur

Lightolier
Lightolier Paralyte 2424 PLA2G9LS26U Manuel utilisateur

Lightolier
Lightolier Lytespan 83ED17S Manuel utilisateur

Lightolier
Lightolier Calculite CS8226 Manuel utilisateur





