1.5 Technical Information
Flow measuring range Rangeable from 0.5 to 5 m/s up to 0.5 to 30 m/s
Accuracy +/- 2% within 12.5° rotation of flow axis
Linearity +/- 1%
Ambient temperature limits -20 to +40°C
Sensor temperature limit -20 to +150°C
Humidity 0 to 95% non-condensing
Protection classification Dust and waterproof to IP65
Process media Air, steam or saturated vapour
Housing material Reinforced polymer
Sensor material Stainless steel - grade 316
Flexible cable (remote
sensor)
PVC coated armoured flexible conduit
Maximum static pressure 20 bar
Process fittings • 11/2” BSP mounting bush
• 50 mm ANSI mounting flange
Cable entry • Side projecting sensing probe - 1 x M20
• Remote mounted sensing probe - 1 x 2M20
Nett weight • Side projecting sensing probe - 1.5 kg
• Remote mounted sensing probe - 2.5 kg
Information display 128 x 64 dot graphic backlit LCD screen
Vibration limits Vibration limits (EN 60079-29-1):
• 10 to 30 Hz - 1.00 mm total excursion
• 31 to 150 Hz - 19.6 m/s2acceleration peak
Impact limits 20 joules (housing)
Output Signals • CommTrac wireless proprietary signal
• Auxiliary analogue output signal (4 to 20 mA)
to drive a local audio visual alarm
Alarms Programmable General and High alarm levels
with built-in LED indicators