Topwell CUT-40Di Manuel utilisateur

OPERATION INSTRUCTIONS
Used for the CUT-40Di/40MV,with input power of 230V or
115/230V, 1-Phase ,50/60HZ.
Sturdy and durable
Plasma cutting machine

Liability relating to the operation of this equipment is restricted solely to the function of the equipment. No other
form of liability, regardless of type, shall be accepted. This exclusion of liability shall be deemed accepted by the
user on commissioning the equipment.
The manufacturer is unable to monitor whether or not these instructions or the conditions and methods are
observed during installation, operation, usage and maintenance of the equipment.
An incorrectly performed installation can result in material damage and injure persons as a result. For this reason,
we do not accept any responsibility or liability for losses, damages or costs arising from incorrect installation,
improper operation or incorrect usage and maintenance or any actions connected to this in any way.
CAUTION
Read the operating instructions!
The operating instructions provide an introduction to the safe use of the products.
• Read the operating instructions for all system components!
• Observe accident prevention regulations!
• Observe all local regulations!
• Confirm with a signature where appropriate.
General instructions

Contents
Notes on the use of these operating instructions
1 Contents
1 Contents...................................................................................................................................................
2 Safety instructions..................................................................................................................................
2.1 Notes on the use of these operating instructions ...........................................................................
2.2 Explanation of icons........................................................................................................................
2.3 General ..........................................................................................................................................
2.4 Transport and installation ...............................................................................................................
2.4.1 Ambient conditions .............................................................................................................
2.4.1.1 In operation .........................................................................................................
2.4.1.2 Transport and storage..........................................................................................
3 Intended use .............................................................................................................................................
3.1 Applications.....................................................................................................................................
3.1.1 Plasma welding ...................................................................................................................
3.2 Documents which also apply .........................................................................................................
3.2.1 Warranty .............................................................................................................................
3.2.2 Declaration of Conformity.....................................................................................................
3.2.3 Welding in environments with increased electrical hazards.................................................
3.2.4 Service documents (spare parts and circuit diagrams) .......................................................
3.2.5 Calibration/Validation ...........................................................................................................
4 Machine description – quick overview .................................................................................................
4.1 Front view........................................................................................................................................
4.2 Rear view........................................................................................................................................
4.3 Machine control – Operating elements...........................................................................................
5 Design and function................................................................................................................................
5.1 General ...........................................................................................................................................
5.2 Machine cooling..............................................................................................................................
5.3 Workpiece lead, general ................................................................................................................
5.4 Transport and installation ...............................................................................................................
5.4.1 Adjusting the length of the carrying strap...........................................................................
5.5 Mains connection.............................................................................................................................
5.5.1 Mains configuration ............................................................................................................
5.6 Shielding gas supply (shielding gas cylinder for welding machine).................................................
5.6.1 Get test ...............................................................................................................................
5.7 Welding torch and workpiece line connection.................................................................................
5.8 Function sequences/operating modes ...........................................................................................
5.8.1 Currentless Test - Simulation mode ...................................................................................
5.8.2 Explanation of symbols ......................................................................................................
5.8.3 Non-latched operation without Up- und Downslope ...........................................................
5.8.4 Non-latched operation.........................................................................................................
5.9 Pilot arc ..........................................................................................................................................
5.10 Welding task selection ..................................................................................................................
03
05
05
06
07
11
12
12
12
13
13
13
14
14
14
14
14
14
15
15
16
17
18
18
18
19
20
20
21
21
22
23
24
25
25
25
25
26
27
27
03
CUT-40Di/40MV

6 Maintenance, care and disposal ...........................................................................................................
6.1 General............................................................................................................................................
6.2 Maintenance work, intervals ...........................................................................................................
6.2.1 Daily maintenance tasks.....................................................................................................
6.2.1.1 Visual inspection ...................................................................................................
6.2.1.2 Functional test .......................................................................................................
6.2.2 Monthly maintenance tasks ................................................................................................
6.2.2.1 Visual inspection ...................................................................................................
6.2.2.2 Functional test ......................................................................................................
6.2.3 Annual test (inspection and testing during operation) .........................................................
6.3 Maintenance work ..........................................................................................................................
6.4 Disposing of equipment..................................................................................................................
6.4.1 Manufacturer's declaration to the end user ........................................................................
6.5 Meeting the requirements of RoHS................................................................................................
7 Rectifying faults.......................................................................................................................................
7.1 Checklist for rectifying faults ...........................................................................................................
8 Technical data..........................................................................................................................................
9 Accessories .............................................................................................................................................
9.1 Standard accessories ....................................................................................................................
9.2 Optional accessories......................................................................................................................
Contents
Notes on the use of these operating instructions
04
CUT-40Di/40MV
28
28
28
28
28
28
28
28
28
28
29
29
29
29
30
30
31
32
32
32

Safety instructions
Notes on the use of these operating instructions
2 Safety instructions
2.1 Notes on the use of these operating instructions
DANGER
Working or operating procedures which must be closely observed to prevent imminent
serious and even fatal injuries.
• Safety notes include the "DANGER" keyword in the heading with a general warning symbol.
• The hazard is also highlighted using a symbol on the edge of the page.
WARNING
Working or operating procedures which must be closely observed to prevent serious
and even fatal injuries.
• Safety notes include the "WARNING" keyword in the heading with a general warning
symbol.
• The hazard is also highlighted using a symbol in the page margin.
CAUTION
Working or operating procedures which must be closely observed to prevent possible
minor personal injury.
• The safety information includes the "CAUTION" keyword in its heading with a general
warning symbol.
• The risk is explained using a symbol on the edge of the page.
CAUTION
Working and operating procedures which must be followed precisely to avoid damaging
or destroying the product.
• The safety information includes the "CAUTION" keyword in its heading without a general
warning symbol.
• The hazard is explained using a symbol at the edge of the page.
NOTE
Special technical points which users must observe.
• Notes include the "NOTE" keyword in the heading without a general warning symbol.
Instructions and lists detailing step-by-step actions for given situations can be recognised via bullet
points, e.g.:
• Insert the welding current lead socket into the relevant socket and lock.
05
CUT-40Di/40MV

ENTER
ENTER
NAVIGATION
EXIT
4s
push
Safety instructions
Explanation of icons
Description
Press
Do not press
Turn
Switch
Switch off machine
Switch on machine
ENTER ENTER (enter the menu)
NAVIGATION NAVIGATION (Navigating in the menu)
EXIT EXIT (Exit the menu)
4 s Time display (example: wait 4s/press)
Interruption in the menu display (other setting options possible)
Tool not required/do not use
Tool required/use
2.2 Explanation of icons
Symbol
Press,turn
06
CUT-40Di/40MV

Safety instructions
General
2.3 General
DANGER
Electric shock!
Welding machines use high voltages which can result in potentially fatal electric shocks
and burns on contact. Even low voltages can cause you to get a shock and lead to
accidents.
• Do not touch any live parts in or on the machine!
• Connection cables and leads must be free of faults!
• Switching off alone is not sufficient!
• Place welding torch and stick electrode holder on an insulated surface!
• The unit should only be opened by specialist staff after the mains plug has been
unplugged!
• Only wear dry protective clothing!
• Wait for 4 minutes until the capacitors have discharged!
Electromagnetic fields!
The power source may cause electrical or electromagnetic fields to be produced which
could affect the correct functioning of electronic equipment such as IT or CNC devices,
telecommunication lines, power cables, signal lines and pacemakers.
• Observe the maintenance instructions! (see Maintenance and Testing chapter)
• Unwind welding leads completely!
• Shield devices or equipment sensitive to radiation accordingly!
• The correct functioning of pacemakers may be affected (obtain advice from a doctor if
necessary).
Do not carry out any unauthorised repairs or modifications!
To avoid injury and equipment damage, the unit must only be repaired or modified by
specialist, skilled persons!
The warranty becomes null and void in the event of unauthorised interference.
• Appoint only skilled persons for repair work (trained service personnel)!
WARNING
Risk of injury due to radiation or heat!
Arc radiation results in injury to skin and eyes.
Contact with hot workpieces and sparks results in burns.
• Use welding shield or welding helmet with the appropriate safety level (depending on the
application)!
• Wear dry protective clothing (e.g. welding shield, gloves, etc.) according to the relevant
regulations in the country in question!
• Protect persons not involved in the work against arc beams and the risk of glare using
safety curtains!
Explosion risk!
Apparently harmless substances in closed containers may generate excessive pressure
when heated.
• Move containers with inflammable or explosive liquids away from the working area!
• Never heat explosive liquids, dusts or gases by welding or cutting!
07
CUT-40Di/40MV

Safety instructions
General
WARNING
CAUTION
Smoke and gases!
Smoke and gases can lead to breathing difficulties and poisoning. In addition, solvent
vapour (chlorinated hydrocarbon) may be converted into poisonous phosgene due to
the ultraviolet radiation of the arc!
• Ensure that there is sufficient fresh air!
• Keep solvent vapour away from the arc beam field!
• Wear suitable breathing apparatus if appropriate!
Fire hazard!
Flames may arise as a result of the high temperatures, stray sparks, glowing-hot parts
and hot slag produced during the welding process.
Stray welding currents can also result in flames forming!
• Check for fire hazards in the working area!
• Do not carry any easily flammable objects such as matches or lighters.
• Keep appropriate fire extinguishing equipment to hand in the working area!
• Thoroughly remove any residue of flammable substances from the workpiece before
starting welding.
• Only continue work on welded workpieces once they have cooled down.
Do not allow to come into contact with flammable material!
• Connect welding leads correctly!
Risk of accidents if these safety instructions are not observed!
Non-observance of these safety instructions is potentially fatal!
• Carefully read the safety information in this manual!
• Observe the accident prevention regulations in your country.
• Inform persons in the working area that they must observe the regulations!
Danger when coupling multiple power sources!
Coupling multiple power sources in parallel or in series has to be carried out by
qualified personnel and in accordance with the manufacturer's guidelines. Before
bringing the power sources into service for arc welding operations, a test has to verify
that they cannot exceed the maximum allowed open circuit voltage.
• Connection of the machine may be carried out by qualified personnel only!
• When decommissioning individual power sources, all mains and welding current leads have
to be safely disconnected from the welding system as a whole (danger due to inverse
voltages)!
Noise exposure!
Noise exceeding 70 dBA can cause permanent hearing damage!
• Wear suitable ear protection!
• Persons located within the working area must wear suitable ear protection!
08
CUT-40Di/40MV

Safety instructions
General
CAUTION
Obligations of the operator!
The respective national directives and laws must be observed for operation of the
machine!
• National implementation of the framework directive (89/391/EWG), as well as the
associated individual directives.
• In particular, directive (89/655/EWG), on the minimum regulations for safety and health
protection when staff members use equipment during work.
• The regulations regarding work safety and accident prevention for the respective country.
• Setting up and operating the machine according to IEC 60974-9.
• Check at regular intervals that users are working in a safety-conscious way.
• Regular checks of the machine according to IEC 60974-4.
Damage due to the use of non-genuine parts!
The manufacturer's warranty becomes void if non-genuine parts are used!
• Only use system components and options (power sources, welding torches, electrode
holders, remote controls, spare parts and replacement parts, etc.) from our range of
products!
• Only insert and lock accessory components into the relevant connection socket when the
machine is switched off.
Damage to the machine due to stray welding currents!
Stray welding currents can destroy protective earth conductors, damage equipment and
electronic devices and cause overheating of components leading to fire.
• Make sure all welding leads are securely connected and check regularly.
• Always ensure a proper and secure electrical connection to the workpiece!
• Set up, attach or suspend all conductive power source components like casing, transport
vehicle and crane frames so they are insulated!
• Do not place any other electronic devices such as drillers or angle grinders, etc., on the
power source, transport vehicle or crane frames unless they are insulated!
• Always put welding torches and electrode holders on an insulated surface when they are
not in use!
Mains connection
Requirements for connection to the public mains network
High-performance machines can influence the mains quality by taking current from the mains
network. For some types of machines, connection restrictions or requirements relating to the
maximum possible line impedance or the necessary minimum supply capacity at the interface
with the public network (Point of Common Coupling, PCC) can therefore apply. In this respect,
attention is also drawn to the machines' technical data. In this case, it is the responsibility of
the operator, where necessary in consultation with the mains network operator, to ensure that
the machine can be connected.
09
CUT-40Di/40MV

CAUTION
Safety instructions
General
10
EMC Machine Classification
In accordance with IEC 60974-10, welding machines are grouped in two electromagnetic
compatibility classes (see technical data):
Class A machines are not intended for use in residential areas where the power supply comes
from the low-voltage public mains network. When ensuring the electromagnetic compatibility of
class A machines, difficulties can arise in these areas due to interference not only in the supply
lines but also in the form of radiated interference.
Class B machines fulfil the EMC requirements in industrial as well as residential areas,
including residential areas connected to the low-voltage public mains network.
Setting up and operating
When operating arc welding systems, in some cases, electro-magnetic interference can occur
although all of the welding machines comply with the emission limits specified in the standard.
The user is responsible for any interference caused by welding.
In order to evaluate any possible problems with electromagnetic compatibility in the
surrounding area, the user must consider the following: (see also EN 60974-10 Appendix A)
• Mains, control, signal and telecommunication lines
• Radios and televisions
• Computers and other control systems
• Safety equipment
• The health of neighbouring persons, especially if they have a pacemaker or wear a hearing
aid
• Calibration and measuring equipment
• The immunity to interference of other equipment in the surrounding area
• The time of day at which the welding work must be carried out
Recommendations for reducing interference emission
• Mains connection, e.g. additional mains filter or shielding with a metal tube
• Maintenance of the arc welding equipment
• Welding leads should be as short as possible and run closely together along the ground
• Potential equalization
• Earthing of the workpiece. In cases where it is not possible to earth the workpiece directly,
it should be connected by means of suitable capacitors.
• Shielding from other equipment in the surrounding area or the entire welding system
CUT-40Di/40MV
Ce manuel convient aux modèles suivants
1
Table des matières

















