4
3Ultrasonic Sensor Installation
3.1 Ultrasonic Sensor Serial Number Arrangement
When installing the ultrasonic sensors, start with the smallest serial number on the left-hand
side, and proceed to the largest serial number on the right-hand side. Each ultrasonic sensor
has a serial number stamped on the sensor housing.
Apply a light coating of the supplied Permatex Anti-seize grease to all threaded
parts upon installation.
Figure 2: Sensor Serial Number Arrangement
Only the brackets shown in black are included in this kit.
The E07 sensors will be mounted in the positions shown in black.
A problem can arise if a sensor is not mounted correctly. It is possible for the
sensor to read off of the boom instead of the ground. This may only become
apparent once the control system is switched from soil to crop mode.
Be careful that the sensor bracket does not collide with any other part of the boom
when the boom is folded to transport position. If possible, mount the sensor
brackets while the booms are folded to ensure they will not cause interference.