1. Before use
…………………………………………
1
2. Nomenclature
………………………………………
2
3. Assemblage
…………………………………………
.5
4. Operation
……………………………………………
7
5. Configuration
………………………………………
13
6. Technical parameter
………………………………
15
7. Troubleshooting
……………………………………
17
1

1 Before use
1-1 NOTICE
1) Microscope ought to be placed in a dry and clean place. Do not expose the microscope
in the sun directly. Avoid high temperature and violent vibration.
2) As microscope is a precision instrument, handle with care, avoiding impact or abrupt
movement during transportation.
3) To keep the image clear, do not leave fingerprints or stains on the surfaces of the lens.
4) Never turn the left and right focusing knob in the adverse direction at the same time,
otherwise the microscope will be damaged.
5) Hold the camera with one hand for fearing of falling when you take the films out of
the big camera.
1-2 MAINTENANCE
1) All lenses must be kept clean. Fine dust on the surface of the lens should be blown off
with hand blower or wiped off gently with a soft lens tissue; Fingerprints or oil marked
on it should be wiped off with a tissue moistened with a small amount of xylene or a
3:7 mixture of alcohol and ether.
2) Never use the organic solution to clean the other surface (especially the plastic
surfaces). If necessary, please choose the neutral detergent.
3) Do not take the microscope apart for fearing that it is damaged.
4) After using, cover the microscope with the dust-cover provided and store it in a dry and
clean place free from moisture to prevent rust.
5) To keep the performance of the microscope, please check it periodically. The detail
can be gotten from the agent nearby.

2 Nomenclature
2-1 SZM-45B1BL2
Eyepiece shield
Eyepiece
Diopter adjusting ring
Head
Illumination device
Zoom control knob
Focusing
Lamp lock-screw
Glass stage
Clip
Base
Top variable light control
Fuse
Bottom variable light control
Switch

2-2 SZM-T1BL2
Diopter adjusting ring Eyepiece shield
Zoom control knob
Eyepiece
Head lock-screw
Head
Focusing knob
Glass stage
Base Clip

3Assemblage
3-1 SZM-45B1BL2
Eyepiece shield
Eyepiece
Head
Head lock-screw
Illumination device
Clips
Glass stage
Base

3-2 SZM-45T1BL2 + SZM-PH OR SZM-CTV

4 Operation
4-1 Use the glass stage
PK-
mount
Photo
eyepiece
Eyepiece
shield
Eyepiec
e
Head
C-
mount
Illumination device
Clip
Glass
stage
Base

1) Press the glass stage on the sunken place then the other side of the glass stage will be
lifted. (Fig.1)
Fig.1
4-2 Adjust the degree of tightness of the focusing arm.
1) If you want to adjust degree of tightness of the focusing arm,
you can hold one of the focusing knobs and turn another one
to attain a suitable position. The degree of tightness relies on
the direction to be turned. The clockwise direction is tight,
otherwise, is loose.
2) The suitable position of tightness can make the adjustment more
comfortable and prevent the focusing bracket from
slipping down by its weight during the observation.
(Fig.2)
4-3 Set the specimen slide
1) Set the specimen on the center of stage plate. If
necessary, clamp the slide with the clips.
2) Turn on the light.
4-4 Adjust the specimen slide
1) Turn the zoom control knob to the maximum
magnification.
2) Turn the diopter adjusting rings to the zero.
3) Observe the specimen through the right eyepiece
and make the
jkj image clear by turning the focusing knob.
Fig.3 4) Rotate the zoom control knob to the minimum magnification.
5) Observe the specimen through the right eyepiece and
make the image clear by turning the right diopter
adjusting ring②.(Fig.3)
6) Redo the step(1),(3),(4)and (5) till the right adjusting
ring is more precise.
Fig.2

7) Do the step (4) and make the image clear which is
observed through the left eyepiece by turning the left
diopter adjusting ring ①. (Fig.3)
4-5 Adjust the interpupillary distance
1) Adjust the prism housing along the direction
of arrowhead of the
Fig.4 till the observation is comfortable.
4-6 Use Eyepiece shields
1) For user who does not wear glasses, hold the diopter-
adjusting ring to prevent them from rotating and turn the
eyepiece till the eyepiece shields fit the observer well.
2) For user who wears glasses, take the eyepiece shields
off before
observation
4-7 Mount and Remove the Optional Eyepiece Micrometer
1) Turn and remove the mounting ring②from the
eyepiece.(Fig.5)
2) Clean the eyepiece micrometer①and mount it to the
mounting
ring with the inscription side downward.
3) Gently twist the mounting ring with the eyepiece micrometer into
the eyepiece till tightening②securely.
4) To remove the eyepiece micrometer, take down the mounting
ring③by twisting and take out of the micrometer, and
then wrap it.
4-8 Install the illumination device
1)Insert the illumination device①in the bracket with the
protrudent
Fig.4
Fig.5

side toward the lock-screw②and tighten the lock-screw. (Fig.6)
2) Put the plug into the socket of the pillar stand③.
Fig.6
4-9 Choose the optical system
1) You can alternate the binocular observation and video
capture by
pushing or pulling the pole. You can attain binocular
observation by
pushing the pole inside, or attain video capture by pulling it
outside.
No matter what optical system is chosen, push or pull the pole
thoroughly.
Fig.7
4-10 Mount the photo eyepiece and the PK-mount
adapter
1) Put the photo eyepieces socket of the tri-ocular.
2) Connect the PK-mount adapter with the photo eyepiece,
and then tighten the lock-screw. (Fig.8)
Fig.8
Fig.9
Fig.10
4-11 Adjust the CTV
1) Adjust the CTV to a suitable position by rotating C-
mount.
Note: The range of the adjustment: 1~2mm in
general.(Fig.9)
4-12 Connect the Digital head With the Monitor
or TV set
1) Plug one end of the PVA cable into the socket of the
digital head. (Fig.10)
2) Plug the C-VIDEO or S-VIDEO of the PVA cable
into the correct socket of Monitor (TV set).
3) Connect the 12V DC power with the power socket
of the PVA cable.
4-13 Appear the image on the Monitor or TV
1) Connect the power supply and then turn on the
Monitor or TV.
Pole
C-mount
Table des matières
Manuels Microscope populaires d'autres marques

VWR
VWR VisiScope 384 Series Manuel utilisateur

Nikon
Nikon ECLIPSE E200 POL Manuel utilisateur

Leica
Leica DI C800 Manuel

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Manuel utilisateur

ThermoFisher Scientific
ThermoFisher Scientific Continuµm Manuel utilisateur

Olympus
Olympus SZ61 Manuel utilisateur