Thelin providence Manuel utilisateur

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
1 of 44
PROVIDENCE INSERT PELLET STOVE
Leave this manual with the owner. Please read this enre manual before installaon and use of the pellet fuel-burning stove. Failure
to follow these instrucons could result in property damage, bodily injury or even death.
SAFETY NOTICE
STOVE MUST BE PROPERLY INSTALLED AND MAINTAINED OR A HOUSE FIRE MAY RESULT.
FOR YOUR SAFETY, FOLLOW THE INSTALLATION INSTRUCTIONS.
CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION AND PERMIT.
FAILURE TO COMPLY WITH OWNER'S MANUAL INSTRUCTIONS AND INSTALLATION GUIDELINES WILL VOID
WARRANTY. SAVE THESE INSTRUCTIONS.
TH-REF-SLS-237 Rev. A

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
2 of 44
Table of Contents
Introducon
-5
Laboratory Lisng Label...................................................................................................................................................... 6
WARNINGS .......................................................................................................................................................................... 7
General Informaon........................................................................................................................................................... 7
Speci®caons.......................................................................................................................................................................... 8
Figure 1 - Stove Dimensions................................................................................................................................................ 8
Vent Informaon.................................................................................................................................................................... 9
Terminaon......................................................................................................................................................................... 9
Distance to openings........................................................................................................................................................... 9
MOBILE HOME INSTALLATION .......................................................................................................................................... 10
Installaon............................................................................................................................................................................ 11
Unpacking and Inspecng your Stove............................................................................................................................... 11
Factory Built (Metal) Fireplace Installaon....................................................................................................................... 11
Masonry Fireplace Installaon.....................................................................................................................................12-13
FIGURE 2 CLEARANCES................................................................................................................................................... 14
Figure 3A- -16
Zero Clearance Built-In (Wood or Metal Framing) Installaon & Minimum Dimensions ...........................................17-18
Figure 5-
Figure 6-
Figure 7-
Figure 8-
Figure 9-
Combuson air adjustment .............................................................................................................................................. 24
Surround Installaon ........................................................................................................................................................ 25
Operaon.............................................................................................................................................................................. 26

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
3 of 44
Start-Up and Operaon CONTROL PANEL ..................................................................................................................... 26
Lighng Instrucons.......................................................................................................................................................... 26
START UP AND OPERATION - HANDHELD REMOTE AND THERMOSTAT .....................................................................26-28
Control Funcons ............................................................................................................................................................. 29
High Temperature / Flue, Trim, and Baery Indicators.................................................................................................... 30
Baery Backup Operaon................................................................................................................................................. 30
EXTERNAL Baery Backup Operaon ............................................................................................................................... 31
Maintenance......................................................................................................................................................................... 32
Daily Maintenance ............................................................................................................................................................ 32
Weekly Maintenance ...................................................................................................................................................32-33
Monthly Maintenance .................................................................................................................................................33-34
Yearly Maintenance .....................................................................................................................................................34-37
Troubleshoong Guide......................................................................................................................................................... 38
Parts List ............................................................................................................................................................................... 39
Figure 16 Replacement Parts List................................................................................................................................... 39
Diagrams..........................................................................................................................................................................40-42
Figure 17 Circuit Board Diagram .................................................................................................................................... 40
Figure 18 - Electrical Schemac/Wiring Diagram ............................................................................................................. 41
Figure 19 - Igniter Locaon ............................................................................................................................................... 42
WARRANTY........................................................................................................................................................................... 43

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
4 of 44
Congratulaons on your purchase of Thelin Hearth Products Providence Insert pellet stove! In this manual you
will ®nd informaon on stove speci®caons, installaon instrucons, operang guide, how to perform
scheduled maintenance, a troubleshoong guide, a detailed parts list and associated diagrams. Also included
is your warranty informaon. Please take the me to read this manual and become familiar with your pellet
stove.
If you have any quesons or comments, please contact your local Thelin authorized dealer. Thelin dealers are
quali®ed industry professionals who are able to address any quesons or comments you might have regarding
Thelin product. Thank you for choosing Thelin.
Safety Informaon
FIRE RISK
Do not operate appliance before reading and understanding operang instrucons.
Failure to operate appliance properly may result in a house ®re.
Inspect appliance and components for damage. Damaged parts may impair safe operaon.
DO NOT install damaged components.
DO NOT install incomplete components.
DO NOT install substute components.
Report damaged parts to dealer.
DO NOT connect this unit into a chimney ¯ue servicing another appliance.
DO NOT connect to any air distribuon or duct system.
WARNING
THELIN HEARTH PRODUCTS DISCLAIMS ANY RESPONSIBILITY FOR, AND THE WARRANTY WILL BE VOIDED BY
THE FOLLOWING ACTIONS:
MODIFICATION OF APPLIANCE
INSTALLATION OTHER THAN AS INSTRUCTED IN THIS MANUAL BY THELIN HEARTH PRODUCTS.
INSTALLATION AND/OR USE OF ANY COMPONENT PART NOT APPROVED BY THELIN HEARTH PRODUCTS.
OPERATING APPLIANCE WITHOUT FULLY ASSEMBLING ALL COMPONENTS CORRECTLY.
Introducon

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
5 of 44
DO NOT over®re. If any external part starts to glow, you are over ®ring. Reduce feed rate.
Over®ring or any such acon that may cause a ®re hazard including failure to perform regular maintenance as
outlined in these instrucons will void warranty.
DO NOT store or use gasoline or other ¯ammable vapors and liquids in the vicinity of this or any other
appliance.
CAUTION
TESTED AND APPROVED FOR PREMIUM WOOD PELLETS OF HIGHEST BTU OUTPUT AND LOWEST % OF ASH
CONTENT ONLY. BURNING ANY OTHER TYPE OF FUEL WILL VOID YOUR WARRANTY.
Fire Safety
Maintain the designated clearances to combustibles as diagramed in this manual. Insulaon must not touch
the chimney or venng system. You must maintain the designated airspace clearance around the chimney.
This space around the chimney is necessary to allow heat to ¯ow away from the chimney area. Insulaon in
this area will cause heat buildup, which could ignite wood framing.
The following should be considered when installing any solid fuel appliance:
1. Install at least one smoke detector on each ¯oor of your home to ensure safety. They should be located
away from the heang appliance and near the sleeping area.
2. Conveniently locate a Class A ®re exnguisher near the appliance.
3. Write down and pracce an evacuaon plan with two escape routes.
Check with your local building code department before you begin your installaon. Obtain a building
permit in order to meet local building code requirements.
Contact your local dealer if assistance is required before, during and aer installaon.
Before Start-Up Check List
1. All Safety Warnings have been read and followed.
2.
3. Floor protecon requirements have been adhered to.
4. All venng has been properly installed.
5. The proper clearances from the stove and chimney to combusble materials have been followed.
6. The masonry chimney has been inspected by a professional and is clean, or the factory built (metal) ®replace is
7. A grounded power outlet with a surge protector is available nearby without having to use an extension cord.

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
6 of 44
Laboratory Lisng Label

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
7 of 44
WARNINGS
HOT SURFACES! HOT GLASS WILL CAUSE BURNS. SURFACES AND GLASS ARE HOT DURING OPERATION AND
DURING COOL-DOWN PERIOD.
DO NOT TOUCH GLASS UNTIL IT IS COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS. ALERT CHILDREN TO HAZARDS OF HIGH TEMPERATURES.
HIGH TEMPERATURES MAY IGNITE CLOTHING OR OTHER FLAMMABLE MATERIALS. KEEP CLOTHING,
FURNITURE, DRAPERIES AND OTHER FLAMMABLE MATERIALS AWAY FROM STOVE.
General Informaon
Installaon and repair should be done by a quali®ed service professional. The stove should be inspected
before use and at least annually by a service professional. More frequent cleaning may be required due to fuel
quality, excessive lint from carpeng, bedding material, etc. It is imperave that control compartments, burn
pot and pot holder, and circulang air passageways of the stove be kept clean and free of ash buildup, lint,
and dust.
The Providence Insert has been designed and approved for burning PREMIUM WOOD PELLETS OF HIGHEST
BTU OUTPUT AND LOWEST % OF ASH CONTENT ONLY.
Burning bio mass fuels in other forms or poor quality pellet fuel is not permied and will void your warranty
and/or could cause a burn back or house ®re. FOR BEST RESULT
Store fuel in a covered, dry area. Pellet bags can absorb moisture and must be kept dry. Never place bags of
fuel next to the heater. Keep fuel away from combusble materials and moisture. NEVER use gasoline,
Keep all such liquids well away from the stove while it is in use.
Pellet ashes should be placed in a metal container with a ght-® ng lid. The closed container of ashes should
be placed on a non-combusble ¯oor or the ground, well away from all combusble materials, pending ®nal
disposal. If the ashes are disposed of by burial in soil or otherwise locally disbursed, they should be retained in
the closed container unl all cinders have been thoroughly exnguished.
NOTE: During the ®rst few burns (up to 2 4 hours) the high-temperature paint and sealant used in the
manufacture will emit some odor and smoke. Open doors and windows to the outside for proper venlaon
during the ®rst burn cycle and the curing of the paint. SEE INITIAL FIRING PROCESS PAMPHLET WITH STOVE.
This stove must be electrically grounded according to local codes or, in the absence of local codes, with the
Naonal Electrical Code, ANSI/NFPA 70-1987.
Provide adequate clearances around air openings into the combuson chamber and provide adequate
accessibility clearance for servicing and proper operaon. Never obstruct the front opening of the stove.

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
8 of 44
Speci®caons
Figure 1 - Stove Dimensions

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
9 of 44
Vent Informaon
Install vent at clearances speci®ed by vent manufacturer.
-TEMP RTV silicone and using at least three sheet
metal screws. Subsequent secons must also be aached with three screws. Each pipe secon should be
sealed with hi-
venng systems!
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
Terminaon
DO NOT terminate vent in any enclosed or semi-enclosed area such as carport, garage, a c, crawl space,
under a sun deck or porch, narrow walkway or closely fenced area or any locaon where fumes can build up
and concentrate such as stairwell, covered breezeway, etc.
Distance to openings
1. 3 feet minimum above any forced air inlet located within 10 feet.
2. 4 . minimum below, or 4 . horizontally from, or 1 foot minimum above any door, window, or gravity
air inlet into any building.
3. Permanently closed windows not less than 1 foot below, horizontally from, or above the permanently
closed window.
4. 2 feet minimum to an adjacent building and 7 feet minimum above grade when located adjacent to
public walkways
5.
6. Grade surface must be non-combusble material such as rock, dirt, gravel. Beware of plants, lawn,
bushes, and shrubs, which are considered combusble material.
7. Consult local building, ®re or other oYcial codes. Local codes may be diVerent and require other
clearances than described here.

Thelin Hearth Products, Inc. Providence Insert Pellet Stove
10 of 44
MOBILE HOME INSTALLATION
Mobile home installaon should be in accordance with the manufactured home and safety standard (HUD),
CFR 3280, PART 24.
The following criteria are mandatory for mobile home installs:
Outside combuson air is mandatory on all mobile home installs. We recommend the Dura ent wall thimble
with outside air hookup built into the thimble. The air inlet must remain unrestricted while unit is in use.
See Figure 6 for locaon of outside air hook-up to the le side of the stove. Metal ¯ex hose must be used for
outside air hook-up.
Stove must be secured to the ¯oor (use lag bolts) in stove feet
The stove must be grounded with #8 solid copper grounding wire or equivalent, terminated at each end with
an NEC-approved grounding device.
A grounded power outlet with a surge protector is recommended.
Clearance to combusbles and ¯oor protecon is exactly the same for mobile homes as residenal installs.
WARNING: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOORS, WALL, CEILING, AND ROOF MUST
BE MAINTAINED. DO NOT INSTALL IN SLEEPING ROOM.
Autres manuels pour providence
2
Autres manuels Thelin Poêle

Thelin
Thelin PARLOUR Manuel

Thelin
Thelin GNOME Manuel utilisateur

Thelin
Thelin PARLOUR Guide d'installation et d'utilisation

Thelin
Thelin PARLOUR Guide d'installation et d'utilisation

Thelin
Thelin Parlour Direct Vent Manuel utilisateur

Thelin
Thelin TIBURON PELLET STOVE Manuel utilisateur

Thelin
Thelin providence Manuel utilisateur
Manuels Poêle populaires d'autres marques

Vermont Castings
Vermont Castings Intrepid 2 Manuel utilisateur

Italiana Camini
Italiana Camini CLASSICA Guide de démarrage rapide

Avalon
Avalon Vashon Avanti DVS FS Manuel utilisateur

Spartherm
Spartherm ambiente a1 Manuel utilisateur

Dimplex
Dimplex MCFSTV12AU Manuel utilisateur

Warmlite
Warmlite WL46040 Manuel utilisateur