WiFi OPERATION
Handset includes rechargeable battery and the running time of this
battery (if full) is approx. 4 hours (continuous usage). Therefore
please S/W OFF always when you don't inspect. The Charging LED
show RED when the battery is charging and this RED LED will be
OFF when the battery is full charged or un-charged. You can see the
below how to charge more detail.
a. Download and install the recommended App (IP Cam Viewer) in
App Store (iPhone) and Google Play Store (Android Smartphone).
b. Handset S/W OFF
c. Handset S/W WiFi and then S/W ON. Waits for a seconds and
then the WiFi LED is blinking with GREEN color.
d. Smartphone Wi-Fi ON and connect to TheFibers AP.
e. Open iOS iPhone and set like below.
- click Menu
- click Manage Cameras
- click Add Camera
- click IP Camera
- set Name
- set Type to "Unknown IP-06"
- set IP/Host to 10.10.1.1
and HTTP to 8196
- click Save
f. Open Android Smartphone App and camera properly like below.
- click Camera Control
- click Setting Icon
- click IP Camera
- set Camera Name
- set Camera Model to
"Unknown IP-06"
- set IP to 10.10.1.1 and
HTTP Port to 8196
- click Save
g. Insert the tip into adaptor or female side of fiber optic devices. You
can feel reaching edge of the adaptor. To get clear images, you have
to rotate 360° FOCUS.
h. Change Tip : The handset basically was assembled by SC/FC/PC
Female Tip. If you want to change Tip to others, it could be changed
by screw easily. Please keep clean lens in Handset when removing
and changing the Tip. The lens is important to get clean images. So
we recommend you should be careful.
USB OPERATION
a. Download and install the supplied software to your PC.
b. Connect Handset to PC by USB to mini 5-pin cable and move
S/W USB and then S/W ON.
c. Run the software (click icon).
[If your software don't work yet, you have to change the name of
Imaging Device.]
d. Check button: To analysis Pass/Fail and Resume to return.
e. Select Single Mode or Multi Mode button.
f. Set Acceptance Criteria
g. Parameter Setting button: To control Video Process and Camera
Control (Setting 1, Setting 2)
h. Change Core/Clad Threshold (recommend 70~90) according to
your PC condition.
i. Save & Print button: After click Check button, you can save (or
print) the analysis report by bmp or jpg file. After click Resume button,
you can capture (or print) the inspected image only automatically like
Capture_0001, Capture_0002....
Charging Battery
a. Connect AC Battery Charger to Handset and the required electric
power is 110/220V@50/60Hz. The full charging time takes about 3
hours. When charging, the S/W position is no problem at ON or OFF
but OFF is more faster.
b. Connect Handset to PC by USB to mini 5-pin cable and then the
battery will be recharged but slowly. During use it with USB operation,
if the Battery is full, the charging process is stopped automatically.
c. The Battery Life Time is about 500 cycles. Unless you use full
battery every day or unless it is charged by un-recommended
Charger, no need battery replacement for long time. To replace the
Battery, the Handset should be sent to TheFibers A/S Center only
and the replacement takes just 1 day.
TheFibers A/S Center
A-1109 Keumkang Penterium IT Tower
282 Hagui-ro, Anyang-City, Korea
Tel: +82-31-381-6108
www.thefibers.com