7
5 6
Preset temperature ( 25 °С)factory setting
When button or is pressed thermoregulator
switches to the mode of display and change of preset
temperature. While flashing, if button «+» is pressed
tpreset will be increased, if button «–» is pressed tpreset
will be decreased.
«–» «+»
Hold down button for a certain number of seconds
(see Table 1). Then change the parameter with the
and buttons. 3 seconds after the last pressing,
the thermostat will automatically return to the sensor
temperature display. In the waiting mode (when the
buttons aren`t currently being used) the brightness of the
indicator and the screen will be reduced to 30 %.
«–»
«+»
«–»
Switching to sleep mode
Hold down the « »
« »oFF
+ button for 4 seconds
(three dashes will appear on the screen one
after the other) until appears
on the screen. To turn it off completely, you
need to turn off the automatic switch.
Button blocking ( )
child and public protection
In order to enable disable button blocking
press the and buttons at the same
time for 6 seconds till the ( ) sign
appears on the screen.
+ –
/
« » « »
«Loc» «oFF»
To exit sleep mode, also hold the « »
« »on
+ button
for 4 seconds until appears
on the screen.
The temperature inside the housing exceeded
8 °C, the protection against internal
overheating worked.
5
Load is off, screen and indicator are off
Heating temperature does not correspond to
the settings
Possible cause: No power supply.
It is necessary: to check the tightening of power wires
in the terminals of the thermostat, make sure that
the switching load power does not exceed the permissible
one, the cross section of the wires for connection are
selected correctly.
Possible cause: load power is not correctly set.
It is necessary: make sure that the supply voltage is
available. If power supply is available, contact the Service
Center.
It is necessary: to correctly set the load power (Tab. 1).
If it is installed correctly, contact the Service Center.
The load does not work, the flashes on the
screen
ПРГ« »
Possible cause: internal overheating of the thermostat,
which can be caused by: poor contact in the terminals
of the thermostat, high ambient temperature, exceeding
the power of the switching load, or the cross section
of the wires for connection is incorrectly selected.
Features of the protection against internal overheating:
when the temperature inside the housing drops below
8 0 °C, the thermostat will resume operation. When
the protection is triggered more than 5 times in a row,
the thermostat will be blocked until the temperature inside
the housing drops below 0 °C and one of the buttons
is pressed.
8
Correction of screen reading
factory setting range( 0, ±5,0 °С,
0,1 °С)step
Firmware version
Load power setting
factory setting 2
0,1 – 3,0 , 0,1 )
1, kW( ,
range kW step kW
Resetting to
factory settings
6 sec
11 sec
9 sec
30 sec
The manufacturer reserves the right to modify the firmware
to enhance the device technical characteristics.
After releasing the button, the thermoregulator will reset
all settings to the factory settings and will reboot.
If necessary you can use the adjustment in the floor
temperature display on the thermostat screen.
Be sure to set the load power. The accuracy of
measurements depends on it.
Possible cause: is a break or short circuit of the
internal overheating sensor. Internal
overheating is not monitored.
Every 5 seconds the screen displays Ert« »
It is necessary: to send the thermostat to the service
center. Otherwise, overheating control will not be carried
out.
SET THE POWER OF THE CONNECTED LOAD
before its operation.
EXPLOITATION
vu11 11_2 201
Do not store the device and do not use it in areas with the
dust.
Turning on and off or and configure the device should be
with dry hands.
Never clean the device with the use of chemicals such as
benzene, solvents.
To protect against overvoltage caused by lightning
discharges, use a lightning protector.
Do not exceed the landmarks value adaptor and power.
Protect the children from games with the working device,
it is dangerous.
Avoid hitting of water or moisture to the device.
Do not expose the device to extreme temperatures
(higher than 40 ºС or below 5 °C) and high humidity.–
Do not connect the device to the network disassembled.
Do not switch the non assembled device to the network.
Do not attempt to disassemble and repair the device.
Carefully read and become aware of yourself these
instructions.
Connection of the device must be done by a qualified
electrician.
Do not connect 230 V mains voltage instead of the sensor
(it leads to failure of the thermostat).
Before the installation (dismantling) and connection
(disconnection) of the device, turn off voltage supply and
also act according to the «Rules of an arrangement of
electric installations».
Do not immerse the sensor with a connecting wire in the
liquid medium.
SAFETY INSTRUCTIONS
Low Voltage Directive 2014/35/E U
1 30 UEMC Directive 20 4/ /E
Manufacturer and vendor: DS ELECTRONICS, LTD
04136,
+38 (091) 1-91-8 , : +38 (091) 1-91-8
support@dse.com.ua www.ds-electronics.com.ua/en/
Ukraine, Kyiv region, Kyiv, 1–3 Pivnichno-Syretska str.
48 1 48 1Service Center
After the end of its service life, the product must be
disposed of in accordance with applicable law.
Transportation of goods carried in the package, ensuring
the safety of the product.
Do not fire and do not throw away the device with the
household waste.
If you have any questions or you something will not clear,
call the Service centre the telephone number listed below.
The device does not contain harmful substances.
The devi e is transported by any kind of transport (rail, sea,
motor, air transportation).
c
Date of manufacture is on the back side of device.
Application time is unlimited.
ADDITIONAL INFORMATION
POSSIBLE PROBLEMS, CAUSES
AND WAYS TO OVERCOME THEM
Menu section NotesScreenHold
« »≡
Table 1. FUNCTION MENU