298-01611-EN R0
REFERENCE GUIDE
Selecting a Mode
Application Mode is set by the Machine Type option on the OEM
Setup Menu. OEM setup mode contains the options that customize
the controller to the sprayer or sprayer components. These include
calibration steps and parameters that will never change once
programmed.
ADVISORY! OEM setup parameters (except Machine Type) should
not be changed unless advised by TeeJet Technologies or an
authorized dealer.
Enter OEM Setup Mode
To enter the OEM setup mode both the 845-AB console and Master
Switch must be off.
Press and hold the PLUS key and MINUS key
simultaneously while pressing the PROGRAMME key one time.
Wait for the display to show “Program menu OEM.”
While continuing to press and hold the PLUS key and
MINUS key simultaneously, press the PROGRAMME key
3 times within 3 seconds to conrm menu access.
Exit OEM Setup Mode
To exit the OEM setup mode the Master Switch must be off.
Press and hold the PROGRAMME key for 3 seconds.
The inputs are stored, and the console will enter the Operation
Screen.
For information on all OEM options, see 845-AB OEM Reference
Guide 98-01612.
SYSTEM SETUP MODE
Enter the System Setup Mode
The Master Switch must be off.
Press and hold the PROGRAMME button until the Program
System Menu screen appears (approximately 3 seconds).
Advance to the Next Option
Press the PROGRAMME button to advance the system to the
next Program step. After the nal setup option is complete, the
console will return to the initial setup option.
Exit the System Setup Mode
Press and hold the PROGRAMME button for 3 seconds.
The inputs are stored, and the console will exit the setup mode.
Step Display Description Default
Units Select the units for operation.
Options include: US, SI.
US
Restore Defaults If the units of measurement are changed, default values for all
settings must be restored.
XYes – Units WILL be changed, and value WILL be reset.
XNo – units will NOT be changed, and value will NOT be
reset.
Yes
Speed Sensor
Calibration
Set number of Pulses per 300 feet/100 metres.
While it is difcult to give an accurate starting value for a wheel
speed sensor, radar (or simulated radar as with GPS speed)
sources usually having a starting value. Make sure the source is
set to “rad”.
100 metres
WTeeJet GPS Speed Sensor – default calibration number is 1300.
WMatrix Pro GS consoles – default calibration number is 914.
WMatrix 430 – default calibration number is 1000.