
5www.teejet.com
Sentry 6141 ISOBUS Tip Flow Monitor
INSTALLATION
If there are questions concerning the installation of the Sentry 6141 ISOBUS Tip Flow Monitor system on this vehicle, or due to the
changes in component specications the parts supplied in the kit are not exactly as presented in this document, please contact your
dealer or TeeJet Customer service representative for clarication before installation. TeeJet Technologies is not responsible for misuse
or incorrect installation of the system.
NOZZLE BODY WITH FLOW METER AND TIP SENSOR INTERFACE
The turbine style ow meter used with the Sentry 6141 ISOBUS Tip Flow Monitor is compact, reliable and proven. The threaded connection allows
the sensor to be added onto a wide range of standard TeeJet single and multiple outlet nozzle bodies. ChemSaver® diaphragm check valves
remain in place allowing for positive spray tip shutoff. Ample clearance inside the ow meter means minimal ow restriction and generous free
passage for particles contained in the spray solution. Long wearing materials are used in bearing surfaces to ensure a consistent ow reading and
the ow meter sensor is mounted externally to prevent any direct contact with the spray solution for long-term reliability.
Flow Meter Assembly
1. Remove end cap from nozzle body.
2. Attach end cap to ow meter (H).
►The ow meter gasket has two different sides. The side with the
larger center is to be inserted towards the sensor or inside the
ow meter.
3. Attach ow meter to nozzle body. Hand tighten.
4. Loosely secure Tip Sensor Interface (F or G) close to nozzle
body / ow meter assembly. Cable ties (not included) can be
threaded through Tip Sensor Interface slots.
5. Push sensor of Tip Sensor Interface into slot on ow meter. Clips
on ow meter should be in the groves on the center of the sensor.
6. Secure Tip Sensor Interface.
7. Connect Start Terminator (J) to section 1 Tip Sensor Interface.
8. Connect each Tip Sensor Interface moving from left to right (while
standing at the back of the machine).
►Extension cables from Boom Interface Module Harness (D) and
Tip Flow Monitor Interface Harness (B) will connect between two
Tip Sensor Interfaces.
9. Connect End Terminator (I) to the last section’s Tip Sensor
Interface.
Figure 4: Flow Monitor Assembly
Tip Sensor Interface
to next Tip Sensor Interface
or End Terminator
to next Tip Sensor Interface
or Start Terminator
Tip Sensor Interface LEDFlow Meter
Nozzle Body End Cap
Nozzle Body & Tips
Tip Sensor
Figure 5: Flow Meter and Gasket Detail
Flow Meter
Gasket
Towards ow meter
Figure 6: Nozzle Body with Flow Meter Assembly
Flow Meter
Nozzle Body
Nozzle Body End Cap