EN
Contents
1. Installation............................................................................. 33
2. Description............................................................................ 34
3. Wireless association ............................................................ 35
4. Configuration ........................................................................ 36
CF01 - Correcting the temperature measured............................ 36
CF02 - Temperature displayed in AUTO mode........................... 37
CF04 - Control type .................................................................... 37
CF05 - Energy saving mode....................................................... 37
CF06 - ON/OFF button display in standby mode........................ 38
CF07 - Backlighting .................................................................... 38
CF08 - Opening detection function............................................. 38
CF09 - Presence detection function ........................................... 39
CF10 - Value of the max. comfort setting.................................... 39
CF11 - Programming format....................................................... 39
CF12 - Time display format ........................................................ 40
CF13 - Automatic change to summer/winter time ...................... 40
CF15 - Display of the symbol ............................................... 40
CF16 - Display of the symbol (heating request) ..................... 40
CF17 - Display of the symbol ............................................. 41
CF18 - Display of the consumption ............................................ 41
CF28 - Anticipation function ..................................................... 42
CF29 - Anticipation sensitivity settings....................................... 42
CF30 - Display of room temperature in shutdown mode ........... 42
5. Setting the clock ................................................................... 43

- 32 -- 32 -
Contents
6. Setting the temperatures (settings) .................................... 44
6.1 Defining the comfort setting.................................................. 44
6.2 Defining the Economy setting............................................... 44
6.3 Defining the Frost protection setting..................................... 44
6.4 Behavioural indicator............................................................ 45
7. Programming ........................................................................ 46
8. AUTO mode ........................................................................... 48
9. "Party" mode......................................................................... 49
10. Absence mode .................................................................... 50
11. External override ................................................................ 51
12. Anticipation......................................................................... 51
13. Information button.............................................................. 52
14. Locking access to the settings ......................................... 53
15. Off mode.............................................................................. 53
16. Return to initial settings.....................................................54
16.1 Automatic reset of parameters to factory setting ................ 54
16.2 Initialisation of all the parameters....................................... 55
17. Remove the wireless association...................................... 56
18. Changing the batteries....................................................... 57
19. Troubleshooting .................................................................. 57
20.Technical characteristics ................................................... 58

- 33 -- 33 -
EN
1. Installation
Place the thermostat:
- in the main room (e.g. living room/dining
room) or in the centre of your home,
- wall-mounted or placed on a piece of
accessible furniture at a height of 1.50 m
- away from heat sources (fireplaces,
sunlight) and draughts (windows, doors)
IMPORTANT: Do not install the thermostat on a wall in contact
with the outdoors or with an unheated room (e.g. garage, etc.).
Mini 20 cm
1
2
3
3
4
5
OR

- 34 -- 34 -
2. Description
❶AUTO mode
❷Comfort mode
❸Economy mode
❹Frost protection
mode
❺Date and time setting/
Programming
❶Time
❷Day
❸Temperature measured
or setting
❹Active setting
❺Wireless transmission
❻"Party" mode
❼Absence mode
❽Information
❾Shutdown mode
Temperature
setting
1
2
3
4
5
1
3
4
2
5
8 96 7
Standby mode:
The product switches to standby mode after a certain time
without any activity. Activate the product by pressing a button
or turning the selector knob

- 35 -- 35 -
EN
>5s
>3s
>5s
2
1
3
4
... ... ...
3. Wireless association
❶Set the receiver(s) to association
mode (refer to receiver guide),
❷The thermostat must be in
shutdown mode.
Press and hold the 2nd button from
the left for 5 seconds.
The screen displays the thermostat version.
❸Press and hold the 2nd button from
the left for 5 seconds again.
The screen displays the rF01 menu.
❹Press OK.
The thermostat searches for the receivers
to associate.
The number of receivers found and
associated is displayed in the centre of
the screen. Number of receivers

- 36 -- 36 -
4. Configuration
The thermostat must be in shutdown mode.
❶Press and hold the 2nd button from the left for 5 seconds.
The screen displays the thermostat version.
❷Press OK.
The screen displays the CF01 menu.
❸Choose your selection or setting with + and -.
Press OK to validate and go to the next setting.
To exit the mode, turn the selector knob
Note: the greyed out sections of the tables match the default
values
CF01 - Correcting the temperature measured
Can be set from -5°C to +5°C.
Example: the temperature displayed by the unit is 19°C and the
actual temperature (thermometer) is 20°C, set +1°C.
>5s
EXIT
-5°C -> +5°C
1 2
3
4

- 37 -- 37 -
EN
4. Configuration
>5s
EXIT
-5°C -> +5°C
1 2
3
4
CF02 - Temperature displayed in AUTO mode
CF04 - Control type
CF05 - Energy saving mode
0Temperature setting
1Temperature measured
0Chrono-proportional (PI) control
1 ON/OFF control
0Display switches off after 10 seconds if nothing is pressed
1 Display switches off between midnight and 5am
2 Display always on

- 38 -- 38 -
4. Configuration
CF06 - ON/OFF button display in standby mode
CF07 - Backlighting
CF08 - Opening detection function
If a door/window magnetic contact (e.g. window) is associated with
the receiver, the heating will switch to Frost protection when the
window is opened.
0Symbol not displayed in standby mode
1Symbol displayed in standby mode
0Disabled
1 Enabled (switches off after timer)
0Disabled
1 Enabled

- 39 -- 39 -
EN
4. Configuration
CF09 - Presence detection function
If a motion detector is associated with the receiver, the
temperature will be lowered automatically in the event of an
extended absence:
• 1.5 h -> Active setting -1.5°C
• 3.5 h -> Active setting -3.5°C
• 48 h -> Frost protection setting
CF10 - Value of the max. comfort setting
Can be set from 22°C to 30°C.
Default value: 28°C
CF11 - Programming format
0Disabled
1 Enabled
0Programming in 1 h steps
1 Programming in 1/2 h steps
Table des matières
Autres manuels Technotherm Thermostat
Manuels Thermostat populaires d'autres marques

EWELLY
EWELLY EW-181 Manuel utilisateur

Prolon
Prolon T1100 Instructions d'installation

Computherm
Computherm Q20 Manuel utilisateur

Heatmiser
Heatmiser neoStat Manuel utilisateur

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manuel utilisateur

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manuel utilisateur