Techly I-ALARM-KPAD Manuel utilisateur

Wireless
Keypad
www.techly.com EN

2
This keypad enables you to arm and disarm your alarm
system, or arm it in Home Mode.
Before entering your home, all you need to do is type
your passcode and press the Disarm button [ ], or swipe
the RFID tag (sold separately) in front of RFID reader to
disarm the system.
Box Content
Keypad X 1
AAA 1.5V batteries X 3
Screws x 4
User’s manual

3
Appearance
LED Indicator
Arm/Unlock
Disarm
Home Mode /
Unlock
SOS key
RFID reader*
*RFID tag (125 KHZ) sold separately.
The keypad supports up to 50 RFID tags.
Refer the instructions on page 9 of this
manual to learn how to register and
RFID tag in the keypad.

4
Rear cover
Battery compartment
Tamper switch

5
Preparation Before Use
How to turn the keypad on
The keypad is powered by 3 AAA batteries. Before using
for the rst time, remove the battery strip.
1. Unscrew and open the case.
2. Insert the batteries according to the positive and
negative signs.
3. Close the case and screw it back.
Remark
Because of the tamper switch, opening the rear cover of
the keypad when the latter is on triggers the alarm. In
such case, stop the alarm by disarming the system, as
explained in page 10 of this manual.

6
Installation
1. Unscrew the case and open it.
2. Screw the rear cover to a door frame or to a wall.
3. Fasten the front cover of the keypad to the real cover
and screw them together.
Remark
Because of the tamper switch, opening the rear cover of
the keypad when the latter is on triggers the alarm. In
such case, stop the alarm by disarming the system, as
explained in page 10 of this manual.

7
Setup
The keypad operates under 4 modes.
Normal mode
The LED indicator blinks once every 5 seconds.
Sleep mode
Under Normal mode, the keypad switches to sleep mode if
no operation is made for 35 seconds. Press the Arm [ ] or
Home Mode [ ] keys to exit Sleep mode. When the keypad
is in sleep mode, the LED indicator is o.
RFID Reader mode
Under Normal mode, press [*] on the keypad to activate
the RFID reader for 10 seconds: the LED indicator turns
on. After 10 seconds, the LED light turns o as the
RFID reader turns o automatically.
Setup mode
To enter Setup mode, switch to Normal mode and then
enter [your admin code+#] on the keypad. The LED in-
dicator blinks once every second. Press [*] to exit the
Setup mode and switch to the Normal mode. After 30
seconds without operation, the keypad goes back to the
Normal mode.
Default admin code: 123456
Remark
Correct operation: 1 beep and the LED light blinks once.
Wrong operation: 2 beeps and LED light blinks twice.

8
Register the keypad in the control panel
Make sure the control panel is in Connection mode (re-
fer to the user’s manual of your alarm system)
Press Arm [ ] or Home Mode [ ]
on the keypad to unlock it.
Type your usercode or admin
code on the keypad, and then
press any of the Arm [ ], Dis-
arm [ ] or Home Mode [ ]
keys. Your hear short beeps: the
registration has succeeded.
Default admin code: 123456. Defaut user code: 1234
The control panel of your alarm system can be con-
trolled from distance on the keypad once the latter has
been registered in the control panel.
Connect the keypad to a siren
The keypad can be connected to an indoor or outdoor
siren, which enables you to trigger the siren by pressing
the [SOS] key on your keypad.
To connect the keypad to a siren, set the wireless siren
to Connection Mode (refer to the manual of your siren if
necessary). Press the Arm [ ] or Home Mode [ ] key on
the keypad to switch to Normal Mode. Then type [your
admin code or user code] and press any of the Arm [ ],
Disarm [ ] or Home Mode [ ] keys on the keypad.

9
Register an RFID tag in the keypad
1. Press Arm [ ] or Home Mode
[] on the keypad to unlock it.
Then type [admin code + #] to
enter Setup Mode.
Default admin code: 123456
If you hear 2 beeps, the code you have typed is wrong.
2. Type [41#]. You hear one
beep and the LED indicator
lights up: the keypad switches
to Connection Mode.
3. Swipe the RFID tag in front
of the RFID reader. You hear
one beep: the connection is
successful.
lf you hear two
beeps, the RFID tags has
already been connected.
Press [*] to exit Setup Mode.
To clear all registred RFID tags, press any of the Arm [ ]
or Home Mode [ ] keys on the keypad to unlock it, and
then type [admin code + #42#]. You hear one beep: the
RFID tags have been deleted from the keypad.

10
Usage
The keypad can be used as a remote control. Your user
code or your admin code will be required before arming
or disarming the system, or switching to Home Mode or
Mute Mode.
Arm the system
1. Press Arm [ ] or Home Mode [ ] on
the keypad to unlock it.
2. Type your user code or admin code.
3. Press the Arm key [ ].The LED indica-
tor blinks once, the keypad beeps once
and sends to the control panel the sig-
nal to arm the system.
When the alarm panel receives the signal, the siren beeps
once and the Arm indicator on the control panel lights up: the
alarm system is now armed.
Default admin code: 123456, default user code: 1234
Disarming the system with the keypad
1. Press Arm [ ] or Home Mode [ ] on
the keypad to unlock it.
2. Type your user code or admin code.
3. Press the Disarm button [ ]: the LED
indicator blinks once, the keypad beeps
once and sends to the control panel the
signal to disarm the system.
When the alarm panel receives the signal, the siren
beeps twice and the Disarm indicator lights up: the
alarm system is now disarmed.