Taylor 741 Manuel utilisateur

OPERATOR’S
MANUAL
Model 702, 741 & 772
Soft Serve Freezers
6/97 (Original Publication)
(Updated 6/28/2018)
Original Operating Instructions
028759-M

Complete this page for quick reference when service is required:
Taylor Distributor: __________________________________________________________
Address:_________________________________________________________________
Phone: __________________________________________________________________
Service: _________________________________________________________________
Parts: ___________________________________________________________________
Date of Installation: ________________________________________________________
Information found on the data label:
Model Number: ___________________________________________________________
Serial Number: ____________________________________________________________
Electrical Specs: Voltage__________________ Cycle__________
Phase__________________________________
Maximum Fuse Size: ______________________________________________________ A
Minimum Wire Ampacity: ___________________________________________________ A
Note: Continuing research results in steady improvements; therefore, information in this manual is subject to change
without notice.
Note: Only instructions originating from the factory or its authorized translation representative(s) are considered to be
the original set of instructions.
© 1997 Taylor Company
028759-M
Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work may be
a violation of copyright law of the United States of America and other countries, could result in the awarding of
statutory damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal
penalties. All rights reserved.
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072

i 028759-M
Table of Contents
Section 1: To the Installer
Installer Safety .............................................................................................................. 1-1
Site Preparation ............................................................................................................ 1-1
Air-Cooled Units............................................................................................................ 1-2
Water Connections ....................................................................................................... 1-2
Electrical Connections .................................................................................................. 1-2
Check Out..................................................................................................................... 1-3
Controls ........................................................................................................................ 1-3
Beater Rotation............................................................................................................. 1-3
Refrigerant .................................................................................................................... 1-3
Section 2: To the Operator
Section 3: Safety
Section 4: Operator Parts Identification
Model 702 .................................................................................................................... 4-1
Model 702 Door Assembly............................................................................................ 4-3
Model 741 ..................................................................................................................... 4-4
Model 772 ..................................................................................................................... 4-6
Model 741 & 772 Door Assembly ................................................................................. 4-8
Section 5: User Interface
Indicator Light—MIX LOW ............................................................................................ 5-1
Symbol Definitions ........................................................................................................ 5-1
Control Switch............................................................................................................... 5-1
Reset Button ................................................................................................................. 5-1
Thermistor Control ........................................................................................................ 5-2
Separate Hopper Refrigeration (SHR) System............................................................. 5-2
Section 6: Operating Procedures
Assembly ...................................................................................................................... 6-1
Sanitizing ...................................................................................................................... 6-4
Priming.......................................................................................................................... 6-5
Closing Procedures ...................................................................................................... 6-6
Draining Product from the Freezing Cylinder................................................................ 6-6
Rinsing.......................................................................................................................... 6-6
Cleaning........................................................................................................................ 6-6
Disassembly ................................................................................................................. 6-7
Brush Cleaning ............................................................................................................. 6-7

028759-M ii
Table of Contents
Section 7: Operator Checklist
During Cleaning and Sanitizing.....................................................................................7-1
Troubleshooting Bacterial Count...................................................................................7-1
Regular Maintenance Checks.......................................................................................7-1
Winter Storage ..............................................................................................................7-2
Section 8: Troubleshooting Guide
Section 9: Parts Replacement Schedule
Section 10: Limited Warranty on Equipment
Section 11: Limited Warranty on Parts

Section 1
1-1
Models 702/741/772
To the Installer
1
To the Installer
The following information has been included in the
manual as safety and regulatory guidelines. For complete
installation instructions, please see the installation
checklist.
!
Installer Safety
IMPORTANT! In all areas of the world,
equipment should be installed in accordance with
existing local codes. Please contact your local authorities
if you have any questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and service
of Taylor®equipment.
• Only authorized Taylor service personnel
should perform installation, maintenance, and
repairs on Taylor equipment.
• Authorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the industry
standards on lockout/tagout procedures before
beginning any installation or repairs.
• Authorized service personnel must ensure that
the Personal Protective Equipment (PPE) is
available and worn when required during
installation and service.
• Authorized service personnel must remove all
metal jewelry, rings, and watches before
working on electrical equipment.
DANGER! The main power supply(s) to the
machine must be disconnected prior to performing any
installation, maintenance, or repairs. Failure to follow this
instruction may result in personal injury or death from
electrical shock or hazardous moving parts as well as
poor performance or damage to the machine.
Note: All repairs must be performed by an authorized
Taylor service technician.
WARNING! This machine has many sharp
edges that can cause severe injuries.
Site Preparation
Review the area where the unit will be installed before
uncrating the unit. Make sure that all possible hazards to
the user and the equipment have been addressed.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of
70°F to 75°F (21°C to 24°C). The freezer has
successfully performed in high ambient temperatures of
104°F (40°C) at reduced capacities.
WARNING! This machine must NOT be
installed in an area where a water jet or hose can be
used. NEVER use a water jet or hose to rinse or clean
the machine. Failure to follow this instruction may result
in electrocution.
CAUTION! This machine must be placed on a
level surface. Extreme care should be taken when
moving for any reason. Two or more persons are
required to safely move this machine. Failure to comply
may result in personal injury or damage to the machine.
Uncrate the unit and inspect it for damage. Report any
damage to your Taylor distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.

1-2
TO THE INSTALLER
Models 702/741/772 To the Installer
1
Air-Cooled Units
Do not obstruct air intake and discharge openings.
The model 702 requires a minimum of 6 in. (152 mm) of
clearance around both sides of the freezer. Install the
deflector on the right side of the unit and place the back
of the unit against the wall to prevent recirculation of
warm air. The models 741 and 772 require a minimum of
3 in. (76 mm) of clearance around all sides. Install the
deflector provided. Failure to allow adequate clearance
can reduce the refrigeration capacity of the freezers and
possibly cause permanent damage to the compressors.
Water Connections
(Water-Cooled Units Only)
An adequate cold water supply must be provided with a
hand shutoff valve. On the underside rear of the base
pan, two 3/8 in. IPS (for single-head units) or two 1/2 in.
IPS (for double head units) water connections for inlet
and outlet have been provided for easy hookup. 1/2 in.
inside diameter water lines should be connected to the
machine. (Flexible lines are recommended, if local codes
permit.) Depending on local water conditions, it may be
necessary to install a water strainer to prevent foreign
substances from clogging the automatic water valve.
There will be only one water in and one water out
connection for both single-head and double-head units.
Do not install a hand shutoff valve on the water out line.
Water should always flow in this order: First, through the
automatic water valve; second, through the condenser;
and third, through the outlet fitting to an open trap drain.
!
IMPORTANT! A backflow prevention device is
required on the incoming water connection side. Please
see the applicable national, state, and local codes for
determining the proper configuration.
Electrical Connections
In the United States, this equipment is intended to be
installed in accordance with the National Electrical Code
(NEC), ANSI/NFPA 70-1987. The purpose of the NEC
code is the practical safeguarding of persons and
property from hazards arising from the use of electricity.
This code contains provisions considered necessary for
safety. In all other areas of the world, equipment should
be installed in accordance with the existing local codes.
Please contact your local authorities.
Each freezer requires one power supply for each data
label. Check the data label(s) on the freezer for branch
circuit overcurrent protection or fuse, wire ampacity, and
electrical specifications. See the wiring diagram provided
inside the electrical box for proper power connections.
WARNING! This machine must be properly
grounded. Failure to do so can result in severe personal
injury from electrical shock.
IMPORTANT! An equipotential grounding lug is
provided with this machine. Some countries require the
grounding lug to be properly attached to the rear of the
frame by the authorized installer. The installation location
is marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on both the removable panel and the
machine's frame.
IMPORTANT!
• Stationary appliances which are not equipped
with a power cord and a plug or another device
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 0.125 in. (3
mm) installed in the external installation.
• Appliances that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected
or not used for long periods, or during initial
installation, shall have protective devices to
protect against the leakage of current, such as a
Ground Fault Interrupter (GFI), installed by the
authorized personnel to the local codes.
• Supply cords used with this machine shall be
oil-resistant, sheathed flexible cable not lighter
!
FOLLOW YOUR LOCAL ELECTRICAL CODES.

TO THE INSTALLER
1-3
Models 702/741/772
To the Installer
1
than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(code designation 60245 IEC 57) installed with
the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals
and protect the insulation of the conductors from
abrasion.
If the supply cord is damaged, it must be replaced by an
authorized Taylor service technician in order to avoid a
hazard.
Check Out
Once the unit is installed, it is advisable to check the
following controls and mechanical operations of the
freezer and make any necessary adjustments. If
applicable, repeat these checks for the second freezing
cylinder on double-head units.
Controls
Place the control switch in the AUTO position. The main
refrigeration system will operate (compressor, beater
motor, and condenser fan). The dial light and the mix low
indicator will be lit.
Figure 1-1
If the freezer is water cooled, the automatic water valve
will begin to open, and cold water will flow into the
condenser. This will remove heat from the refrigerant. As
the water flows into the open trap drain, it should be
warm to the touch. Place the control switch in the OFF
position.
Beater Rotation
NOTICE! Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
To correct the rotation on a three-phase machine,
interchange any two incoming power supply lines at the
freezer main terminal block only. To correct rotation on a
single-phase machine, exchange leads inside the beater
motor. (Follow the diagram printed on the motor.)
Electrical connections are made directly to the terminal
block provided in the main control box located behind the
service panel.
It is recommended that beater rotation be performed by
an authorized Taylor service technician.
Refrigerant
CAUTION! In consideration of our environment,
Taylor uses only earth-friendly hydro-fluorocarbon (HFC)
refrigerants. The HFC refrigerant used in this machine is
R404A. This refrigerant is generally considered nontoxic
and nonflammable, with an Ozone Depleting Potential
(ODP) of zero (0). However, any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion.
!
CAUTION! Use only R404A refrigerant that
conforms to the Air-Conditioning, Heating and
Refrigeration Institute (AHRI) standard 700 specification.
The use of any other refrigerant may expose users and
operators to unexpected safety hazards.
WARNING! Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
13998

1-4
TO THE INSTALLER
Models 702/741/772 To the Installer
1
and skin protected. If refrigerant burns should occur,
flush immediately with cold water. If burns are severe,
apply ice packs and contact a physician immediately.

TO THE INSTALLER
1-5
Models 702/741/772
To the Installer
1
NOTICE! Taylor reminds technicians to be
aware of and in compliance with local government laws
regarding refrigerant recovery, recycling, and reclaiming
systems. For information regarding applicable local laws,
please contact your local authorized Taylor distributor.
!
IMPORTANT! R404A refrigerant used in
conjunction with polyolester oils is extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.

1-6
TO THE INSTALLER
Models 702/741/772 To the Installer
1
Ce manuel convient aux modèles suivants
2
Table des matières
Autres manuels Taylor sorbetière

Taylor
Taylor Wawa C708 Manuel utilisateur

Taylor
Taylor C125 Instructions d'utilisation

Taylor
Taylor Freezemaster 336 Manuel utilisateur

Taylor
Taylor 441 Manuel utilisateur

Taylor
Taylor 142 Manuel utilisateur

Taylor
Taylor Horizon 8756 Manuel utilisateur

Taylor
Taylor Soft Serve Little Softy Manuel utilisateur

Taylor
Taylor Wawa C708 Manuel utilisateur

Taylor
Taylor Taylormate 152 Manuel utilisateur

Taylor
Taylor Freezemaster 336 Manuel utilisateur