suprema OM-120 Manuel utilisateur

Output Module
INSTALLATION GUIDE
Version 1.01
English
EN 101.00.OM-120 V1.01A

CONTENTS
Safety information 2
Instructional icons 2
Introduction 4
Components 4
Accessory 5
Name of each part 6
LED Indicator 7
Installation example 7
Installation 8
Power Connection 8
RS-485 Connection 9
Relay Connection 10
AUX 11
Using the Output Module with the enclosure 12
Product Specifications 16
Dimensions 17
FCC compliance information 18
Appendices 19
Disclaimers 19
Copyright Notice 19

2
Safety information
Safety information
Please read this safety instructions before you use the product to prevent injury to yourself and others and to prevent
property damage. The term 'product' in this manual refers to the product and any items provided with the product.
Instructional icons
Warning: This symbol indicates situations that could result in death or severe injury.
Caution: This symbol indicates situations that may result in moderate injury or property damage.
Note: This symbol indicates notes or additional information.
Warning
Installation
Do not install or repair the product arbitrarily.
• This may result in electric shock, fire, or product damage.
• Damages caused by any modifications or failure to follow installation instructions can void the manufacturer’s warranty.
Do not install the product in a place with direct sunlight, moisture, dust, soot, or a gas leak.
• This may result in electric shock or fire.
Do not install the product in a location with heat from an electric heater.
• This may result in fire due to overheating.
Install the product in a dry location.
• Humidity and liquids may result in electric shock or product damage.
Do not install the product in a location where it will be affected by radio frequencies.
• This may result in fire or product damage.
Operation
Keep the product dry.
• Humidity and liquids may result in electric shock, fire, or product damage.
Do not use damaged power supply adaptors, plugs, or loose electrical sockets.
• Unsecured connections may cause electric shock or fire.
Do not bend or damage the power cord.
• This may result in electric shock or fire.

3
Safety information
Caution
Installation
Do not install the power supply cable in a location where people pass by.
• This may result in injury or product damage.
Do not install the product near magnetic objects, such as a magnet, TV, monitor (especially CRT), or speaker.
• The product may malfunction.
Operation
Do not drop the product or cause impacts to the product.
• The product may malfunction.
Do not disconnect the power supply while upgrading the firmware of the product.
• The product may malfunction.
Do not press buttons on the product by force or do not press them with a sharp tool.
• The product may malfunction.
When cleaning the product, mind the following.
• Wipe the product with a clean and dry towel.
• If you need to sanitize the product, moisten the cloth or the wipe with a proper amount of rubbing alcohol and gently
clean all exposed surfaces including the fingerprint sensor. Use rubbing alcohol (containing 70% Isopropyl alcohol) and a
clean, non-abrasive cloth like lens wipe.
• Do not apply liquid directly to the surface of the product.
Do not use the product for anything other than its intended use.
• The product may malfunction.

4
Introduction
Introduction
Components
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
RELAY 0 RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
RELAY 11RELAY 10RELAY 9RELAY 8
RELAY 7
RELAY 6
POWER STATUS
RESET INIT
12V
0V
TRX+
TRX-
GND
POWER
GND
AUX IN 1
GND
AUX IN 0
AUX
RS-485
ON OFF
TERM
0
1
2
3
4
5
11
10
9
8
7
6
OM 120
-
Output Module
(OM-120) Drilling Template
Fixing screw x12 Spacer x6
• Components may vary according to the installation environment.

5
Introduction
Accessory
You can use the Output Module with the enclosure (ENCR-10). The enclosure is sold separately, and you can install two
Output Modules in one enclosure. The enclosure includes a power status LED board, power distribution board, power
supply, and tamper. To learn how to install the Output Module in the enclosure, refer to Using the Output Module with
the enclosure.
• There is no optimal height for installing ENCR-10 on the wall. Install it to a safe and convenient location for you
to use.
• Fixing screws for the enclosure, the device, and the power supply cable are included in the ENCR-10 package.
Use each screw correctly by following the details below.
- Fixing screws for the enclosure (diameter: 4 mm, length: 25 mm) x 4
- Fixing screws for the device (diameter: 3 mm, length: 5 mm) x 6
- Fixing screws for the power supply cable (diameter: 3 mm, length: 8 mm) x 1
ENCR-10

6
Introduction
Name of each part
5
• Press INIT button to reset Output Module interworking with a device and then connect to another device.
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
RELAY 0 RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
RELAY 11RELAY 10RELAY 9RELAY 8
RELAY 7
RELAY 6
POWER STATUS
RESET INIT
12V
0V
TRX+
TRX-
GND
POWER
GND
AUX IN 1
GND
AUX IN 0
AUX
RS-485
ON OFF
TERM
0
1
2
3
4
5
11
10
9
8
7
6
OM 120
-
RESET button
INIT button
Communication
status LED
(RS-485, AUX)
Power status LED Operation status LED
Relay 0 Relay 11
Relay 9
Relay 7
AUX1
Relay 10
Relay status LED
(0, 1, 11, 10)
Relay status LED
(2, 3, 9, 8)
Relay status LED
(4, 5, 7, 6)
Relay 8
Relay 6
AUX0
Relay 1
Relay 2
Relay 3
Relay 4
Relay 5
Power
RS-485
Termination
Switch

7
Introduction
LED Indicator
You can check the status of the device by the color of the LED indicator.
Item LED Status
POWER Solid red Power on
STATUS
Solid green Connected with the secure session
Solid blue Disconnected from a master device
Solid pink Upgrading the firmware
Solid yellow RS-485 communication error due to different encryption key or OSDP
packet loss
Solid sky blue Connected without the secure session
RELAY (0 - 11) Solid red Relay operation
RS-485 TX Blinking green Transmitting RS-485 data
RS-485 RX Blinking orange Receiving RS-485 data
AUX IN (0, 1) Solid orange Receiving an AUX signal
Installation example
OM-120 is an expansion module for floor access control. Combined with Suprema device and BioStar 2, a single module
can control 12 floors. When the OM-120 is connected as daisy chain via RS-485, you can control up to 192 floors per
elevator.
B3
B2
B1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
RELAY0 RELAY1 RELAY2 RELAY3 RELAY4 RELAY5
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
RELAY11RELAY10RELAY9RELAY8
RELAY7
RELAY6
POWER STATUS
RESET INIT
12V
0V
TRX+
TRX-
GND
POWER
GND
AUXIN 1
GND
AUXIN 0
AUX
RS-485
ON OFF
TERM
0
1
2
3
4
5
11
10
9
8
7
6
OM 120
-
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
RELAY0 RELAY1 RELAY2 RELAY3 RELAY4 RELAY5
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
RELAY11RELAY10RELAY9RELAY8
RELAY7
RELAY6
POWER STATUS
RESET INIT
12V
0V
TRX+
TRX-
GND
POWER
GND
AUXIN 1
GND
AUXIN 0
AUX
RS-485
ON OFF
TERM
0
1
2
3
4
5
11
10
9
8
7
6
OM 120
-
BioStar 2
TCP/IP
Relay
Relay
Relay
Controller / Reader
Floor Button
Call button
controller
Call button
controller
Call button
controller
RS-485
OM-120OM-120
RS-485
Elevator

8
Installation
Installation
Output Module can be mounted in the enclosure or elevator control panel.
• To learn how to install the Output Module in the enclosure, refer to Using the Output Module with the
enclosure.
1
Fix a spacer on the position to mount Output Module using a fixing screw.
2
Fix the product on top of the fixed spacer firmly using a fixing screw.
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
RELAY 0 RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
RELAY 11RELAY 10RELAY 9RELAY 8
RELAY 7
RELAY 6
POWER STATUS
RESET INIT
12V
0V
TRX+
TRX-
GND
POWER
GND
AUX IN 1
GND
AUX IN 0
AUX
RS-485
ON OFF
TERM
0
1
2
3
4
5
11
10
9
8
7
6
OM 120
-
Power Connection
NO
COM
NC
NO
COM
NC
RELAY 4 RELAY 5
12V
0V
TRX+
TRX-
GND
POWER RS-485
ON OFF
TERM
DC
Power
• Make sure to use separate power for the access control device and Output Module.
• Use the correct power specifications (12 VDC, 1 A).
• It is recommended to connect and use an Uninterruptible Power Supply (UPS) to prevent power failure.

9
Installation
RS-485 Connection
• RS-485 should be AWG24, twisted pair, and maximum length is 1.2 km.
• Connect a termination resistor (120Ω) to both ends of a RS-485 daisy chain connection. It should be installed at both
ends of the daisy chain. If it is installed in the middle of the chain, the performance in communicating will deteriorate
because it reduces the signal level.
• Up to 31 modules can be connected to the master device.
NO
COM
NC
NO
COM
NC
RELAY 4 RELAY 5
NC
COM
NO
NC
COM
NO
RELAY 7
RELAY 6
12V
0V
TRX+
TRX-
GND
POWER
GND
AUX IN 1
GND
AUX IN 0
AUX
RS-485
ON OFF
TERM
4
5
7
6
NO
COM
NC
NO
COM
NC
RELAY 4 RELAY 5
12V
0V
TRX+
TRX-
GND
POWER RS-485
ON OFF
TERM
Access Controller
OM-120
Termination
RS-485
TRX+
RS-485
TRX-
Terminating
resistance
(120Ω)
GND
Autres manuels pour OM-120
1
Table des matières
Autres manuels suprema Système d'E/S