Supero SBI-7226T-T2 Manuel utilisateur

SBI-7226T-T2
Blade Module
User’s Manual
Revison 1.0a

SBI-7226T-T2 Blade Module User’s Manual
ii
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The
vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no
commitment to update or to keep current the information in this manual, or to notify any person or
organization of the updates. Please Note: For the most up-to-date version of this manual, please see
our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described
in this manual at any time and without notice. This product, including software and documentation, is the
property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction
of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE
THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE,
SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF
REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE,
SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara
County in the State of California, USA. The State of California, County of Santa Clara shall be the
exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not
exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital
device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the manufacturer’s instruction manual, may cause harmful interference with radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference,
in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning
applies only to products containing CR (Manganese Dioxide) Lithium coin cells. Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate for further
details.
Manual Revison 1.0a
Release Date: May 18, 2011
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy
any part of this document.
Information in this document is subject to change without notice. Other products and companies referred
to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2011 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
WARNING: HANDLING OF LEAD SOLDER MATERIALS USED IN THIS
PRODUCT MAY EXPOSE YOU TO LEAD, A CHEMICAL KNOWN TO THE
STATE OF CALIFORNIA TO CAUSE BIRTH DEFECTS AND OTHER
REPRODUCTIVE HARM.

iii
Preface
About this Manual
This manual is written for professional system integrators, Information Technology
professionals, service personnel and technicians. It provides information for the
installation and use of Supermicro's SBI-7226T-T2 Blade Module. Installation and
maintenance should be performed by experienced professionals only.
Manual Organization
Chapter 1: Introduction
The first chapter provides a checklist of the main components included with the
SBI-7226T-T2 Blade Module and describes its main features.
Chapter 2: System Safety
You should familiarize yourself with this chapter for a general overview of safety
precautions that should be followed when installing and servicing the SBI-7226T-T2
Blade Module.
Chapter 3: Setup and Installation
Refer to this chapter for details on installing the SBI-7226T-T2 Blade Module into the
SuperBlade chassis. Other sections cover the installation and placement of memory
modules and the installation of hard disk drives into the blade module.
Chapter 4: Blade Module Features
This chapter coves features and component information about the SBI-7226T-T2 Blade
Module. Included here are descriptions and information for mainboard components,
connectors, LEDs and other features of the blade module.
Chapter 5: RAID Setup Procedure
RAID setup and operations for the SBI-7226T-T2 Blade Module are covered in this
chapter.
Chapter 6: BIOS
BIOS setup is covered in this chapter for the SBI-7226T-T2 Blade Module.
Appendix A: BIOS POST Codes
BIOS POST Codes for the SBI-7226T-T2 Blade Module are explained in this appendix.

SBI-7226T-T2 Blade Module User’s Manual
iv
Notes

v
Table of Contents
Chapter 1 Introduction.......................................................................1-1
1-1 Overview.............................................................................................1-1
1-2 Product Checklist of Typical Components.....................................1-1
1-3 Blade Module Features....................................................................1-2
Processors..............................................................................................1-2
Memory...................................................................................................1-2
Storage....................................................................................................1-3
Density....................................................................................................1-3
1-4 Contacting Supermicro.....................................................................1-5
Chapter 2 System Safety..................................................................2-1
2-1 Electrical Safety Precautions...........................................................2-1
2-2 General Safety Precautions.............................................................2-2
2-3 Electrostatic Discharge Precautions ..............................................2-2
2-4 Operating Precautions......................................................................2-3
Chapter 3 Setup and Installation.................................................3-1
3-1 Overview.............................................................................................3-1
3-2 Installing Blade Modules..................................................................3-1
Powering Up a Blade Unit.......................................................................3-1
Powering Down a Blade Unit ..................................................................3-1
Removing a Blade Unit from the Enclosure............................................3-1
Removing/Replacing the Blade Cover....................................................3-2
Installing a Blade Unit into the Enclosure ...............................................3-2
3-3 Processor Installation.......................................................................3-4
3-4 Onboard Battery Installation............................................................3-5
3-5 Memory Installation...........................................................................3-6
Populating Memory Slots........................................................................3-6
DIMM Installation ....................................................................................3-8
3-6 Hard Disk Drive Installation.............................................................3-9
3-7 Installing the Operating System....................................................3-11
Installing with an External USB CD-ROM Drive....................................3-11
Installing via PXE Boot..........................................................................3-11
Installing via Virtual Media (Drive Redirection) .....................................3-12
3-8 Management Software...................................................................3-12

SBI-7226T-T2 Blade Module User’s Manual
vi
3-9 Configuring and Setting up RAID .................................................3-12
Chapter 4 Blade Module Features..............................................4-1
4-1 Control Panel.....................................................................................4-2
Power Button ..........................................................................................4-3
KVM Button.............................................................................................4-3
LED Indicators ........................................................................................4-3
KVM Connector.......................................................................................4-3
4-2 Mainboard...........................................................................................4-4
Jumpers..................................................................................................4-7
CMOS Clear............................................................................................4-7
4-3 Blade Unit Components...................................................................4-8
Memory Support .....................................................................................4-9
Hard Disk Drives.....................................................................................4-9
Chapter 5 RAID Setup Procedure...............................................5-1
5-1 BIOS Configuration Utilities.............................................................5-2
5-2 BIOS Setup........................................................................................5-2
Chapter 6 BIOS.......................................................................................6-1
6-1 Introduction.........................................................................................6-1
Running Setup........................................................................................6-1
6-2 Main BIOS Setup Menu ...................................................................6-1
System Time/System Date .....................................................................6-2
6-3 Advanced Settings Menu.................................................................6-2
CPU & Clock Configuration.....................................................................6-3
IDE Configuration....................................................................................6-4
PCI/PnP Configuration............................................................................6-5
Super IO Configuration...........................................................................6-6
Chipset Configuration .............................................................................6-6
CPU Bridge Configuration....................................................................6-7
NorthBridge Configuration....................................................................6-7
SouthBridge Configuration...................................................................6-8
ACPI Configuration.................................................................................6-9
AHCI Configuration.................................................................................6-9
Event Log Configuration .......................................................................6-10
IPMI Configuration ................................................................................6-10
Intel VT-d Configuration........................................................................6-11
MPS Configuration................................................................................6-11
PCI Express Configuration....................................................................6-12

vii
SMBIOS Configuration..........................................................................6-12
Remote Access Configuration ..............................................................6-12
System Health Monitor..........................................................................6-13
6-4 Boot Menu........................................................................................6-13
6-5 Security Menu..................................................................................6-14
6-6 Exit Menu..........................................................................................6-15
Appendix A BIOS POST Codes....................................................A-1
A-1 BIOS POST Messages....................................................................A-1
A-2 BIOS POST Codes...........................................................................A-3
Recoverable POST Errors......................................................................A-4
Terminal POST Errors.............................................................................A-4

SBI-7226T-T2 Blade Module User’s Manual
viii
Notes

ix
List of Figures
Figure 1-1. Full Rack of Blade Enclosures and Blade Servers.........................1-4
Figure 3-1. Inserting a Blade into the Enclosure...............................................3-3
Figure 3-2. Locking the Blade into Position.......................................................3-3
Figure 3-3. Installing a Processor in a Socket...................................................3-5
Figure 3-4. Installing the Onboard Battery........................................................3-5
Figure 3-5. 8-Slot DIMM Numbering.................................................................3-7
Figure 3-6. Installing a DIMM into a Memory Slot.............................................3-8
Figure 3-7. Installing a Hard Drive in a Carrier................................................3-10
Figure 4-1. SBI-7226T-T2 Blade Unit Front View .............................................4-1
Figure 4-2. Blade Control Panel........................................................................4-2
Figure 4-3. B8DTT Mainboard ..........................................................................4-5
Figure 4-4. Intel 5500/IOH-24D Tylersburg + ICH10R Chipset:
Block Diagram
for SBI-7226T-T2 ..............................................................................................4-7
Figure 4-5. Exploded View of SBI-7226T-T2 Blade Module .............................4-8
Figure 5-1. Advanced Settings Screen .............................................................5-2
Figure 5-2. IDE Configuration Screen – Configure RAID Drives.......................5-3
Figure 5-3. Selecting Max Ports Option............................................................5-4
Figure 5-4. Selecting RAID Utility......................................................................5-5
Figure 5-5. Enabling Hot Plug...........................................................................5-6
Figure 5-6. Exit BIOS Setup..............................................................................5-7
Figure 5-7. Screen Message.............................................................................5-8

SBI-7226T-T2 Blade Module User’s Manual
x
Notes
Table des matières
Autres manuels Supero Matériel réseau
Manuels Matériel réseau populaires d'autres marques

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuel utilisateur

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuel utilisateur

Yudor
Yudor YDS-16 Manuel utilisateur

D-Link
D-Link ShareCenter DNS-320L Manuel utilisateur

Samsung
Samsung ES1642dc Instructions d'utilisation

Honeywell Home
Honeywell Home LTEM-PV Instructions de montage













