Sun Microsystems XCP2040-TRN Manuel utilisateur

Sun Microsystems, Inc.
4150 Network Circle
Santa Clara, CA 95054 U.S.A.
650-960-1300
XCP2040-TRN I/O
Transition Card Manual
For Netra™CP2040 and Netra CP2140 CompactPCI
Boards
Part No. 806-6743-11
October 2002, Revision A

Copyright 2002 Sun Microsystems, Inc., 4150 Network Circle,Santa Clara, California 95054, U.S.A. All rights reserved.
Sun Microsystems, Inc. has intellectual property rights relating to technology embodied in the product that is described in this document. In
particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at
http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries.
This document and the product to which it pertains are distributed under licenses restricting their use, copying, distribution, and
decompilation. No part of the product or of this document may be reproduced in any form by any means without prior written authorization of
Sun and its licensors, if any.
Third-party software, including font technology, is copyrighted and licensed from Sun suppliers.
Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in
the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd.
Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, Netra and Solaris are trademarks or registered trademarks of Sun
Microsystems, Inc. in the U.S. and in other countries.
All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and in other
countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc.
The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges
the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun
holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN
LOOK GUIs and otherwise comply with Sun’s written license agreements.
Use, duplication, or disclosure by the U.S. Government is subject to restrictions set forth in the Sun Microsystems, Inc. license agreements and as
provided in DFARS 227.7202-1(a) and 227.7202-3(a) (1995), DFARS 252.227-7013(c)(1)(ii) (Oct. 1998), FAR 12.212(a) (1995), FAR 52.227-19, or
FAR 52.227-14 (ALT III), as applicable.
DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.
Copyright 2002 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés.
Sun Microsystems, Inc. a les droits de propriété intellectuels relatants à la technologie incorporée dans le produit qui est décrit dans ce
document. En particulier, et sans la limitation, ces droits de propriété intellectuels peuvent inclure un ou plus des brevets américains énumérés
à http://www.sun.com/patents et un ou les brevets plus supplémentaires ou les applications de brevet en attente dans les Etats-Unis et dans
les autres pays.
Ce produit ou document est protégé par un copyright et distribué avec des licences qui en restreignent l’utilisation, la copie, la distribution, et la
décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, parquelque moyen que ce soit, sans
l’autorisation préalable et écrite de Sun et de ses bailleurs de licence, s’il y ena.
Le logiciel détenu par des tiers, et qui comprend la technologie relative auxpolices de caractères, est protégé par un copyright et licencié par des
fournisseurs de Sun.
Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque
déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd.
Sun, Sun Microsystems, le logo Sun, AnswerBook2, docs.sun.com, Netra et Solaris sont des marques de fabrique ou des marques déposées de
Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays.
Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc.
aux Etats-Unis et dans d’autres pays. Les produits protant les marques SPARC sont basés sur une architecture développée par Sun
Microsystems, Inc.
L’interface d’utilisation graphique OPEN LOOK et Sun™ a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun
reconnaît les efforts de pionniers de Xerox pour la recherche et le développment du concept des interfaces d’utilisation visuelle ou graphique
pour l’industrie de l’informatique. Sun détient une license non exclusive do Xerox sur l’interface d’utilisation graphique Xerox, cette licence
couvrant également les licenciées de Sun qui mettent en place l’interface d ’utilisation graphique OPEN LOOK et qui en outre se conforment
aux licences écrites de Sun.
LA DOCUMENTATION EST FOURNIE "EN L’ÉTAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT
TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A
L’ABSENCE DE CONTREFAÇON.

3
Contents
Features 2
I/O Interfaces 3
PIM Card Support 4
SIP Switch Settings 5
Switch SW1101—SCSI Termination 6
Switch SW1401—I2C Write Protect 7
Switch SW0501—Ethernet Boot Selection 7
Software Support 8
Specifications 8
Mechanical Dimensions 8
Power Requirements 8
Environmental Specifications, Compliance, Reliability, and
Availability 9
Determining Part Number, Serial Number, and Revision Number 9
Connectors 10
Upgrading Backplanes for PICMG Compliance 10
Transition Card I/O Rear Panel Connectors 11
USB Ports 12
Serial Ports 13
Fast Ethernet 14

4XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002
SCSI Connectors 14
On-Board Interfaces/Connectors on
XCP2040-TRN I/O Transition Card 16
I2C Bus Access Header 17
PIM Connectors 18
On-board SCSI Connector 19
Parallel Port 20
Floppy Header Connector 21
Backplane Interface 22
J3 Connector 22
J4 Connector 24
J5 Connector 25
PIM Card Interface 28
Installing the Transition Card in a CompactPCI Chassis 30

5
Preface
The XCP2040-TRN I/O Transition Card (P/N 806-6743-11) is a fully compatible,
carrier-grade CompactPCI I/O card designed for the Netra™ CP2040/CP2140
CompactPCI boards. This manual describes the functions of the XCP2040-TRN I/O
Transition Card, its specifications, connectors, and installation process.
Who Should Use This Book
The XCP2040-TRN I/O Transition Card Manual for Netra CP2040 and Netra CP2140
CompactPCI Boards is written for computer hardware engineers, system
programmers, computer technicians, and others involved in the integration of the
Netra CP2040/CP2140 boards. References are provided for further details.
Related References
This section provides a list of related references.
Specifications and Standards
■CompactPCI Core Specification, Release Note for PICMG 2.0 Revision 3.0, October 1999,
PCI Industrial Computers Manufacturers Group
■IEEE Standard 1101.11-1998, Standard For Mechanical Rear Plug-in Units
Specifications for Microcomputers Using IEEE 1101.1 and IEEE 1101.10 Equipment
Practice

6XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002
■VITA 36, PMC I/O Module Draft Standard
■Ethernet IEEE 802.3 Standard
■Universal Serial Bus Specification Rev. 1.1
■I2C-Bus Specification Version 2.1
Related Documents
■Netra CP2040 Technical Reference and Installation Manual
(P/N 806-4994-xx)
■Netra CP2140 Technical Reference and Installation Manual
(P/N 816-4908-xx)
Using UNIX Commands
This document might not contain information on basic UNIX®commands and
procedures such as shutting down the system, booting the system, and configuring
devices.
See one or more of the following for this information:
■Solaris Handbook for Sun Peripherals
■AnswerBook2™online documentation for the Solaris™operating environment
■Other software documentation that you received with your system

Preface 7
Typographic Conventions
Shell Prompts
Typeface Meaning Examples
AaBbCc123 The names of commands, files,
and directories; on-screen
computer output
Edit your.login file.
Use ls -a to list all files.
% You have mail.
AaBbCc123 What you type, when contrasted
with on-screen computer output %su
Password:
AaBbCc123 Book titles, new words or terms,
words to be emphasized.
Replace command-line variables
with real names or values.
Read Chapter 6 in the User’s Guide.
These are called class options.
You must be superuser to do this.
To delete a file, type rm filename.
Shell Prompt
C shell machine-name%
C shell superuser machine-name#
Bourne shell and Korn shell $
Bourne shell and Korn shell superuser #

8XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002
Accessing Sun Documentation Online
You can view and print a broad selection of Sun™ documentation, including
localized versions, at:
http://www.sun.com/documentation
You can also purchase printed copies of select Sun documentation from iUniverse,
the Sun documentation provider, at:
http://corppub.iuniverse.com/marketplace/sun/
Sun Welcomes Your Comments
Sun is interested in improving its documentation and welcomes your comments and
suggestions. You can email your comments to Sun at:
Please include the part number (806-6743-11) of your document in the subject line of
your email.

1
XCP2040-TRN I/O Transition Card
Manual for Netra CP2040/CP2140
CompactPCI Boards
The XCP2040-TRN I/O Transition Card (806-6743-11) is designed to be used with the
Netra CP2040/CP2140 CompactPCI boards and is fully compliant with the
CompactPCI Core Specification, Release Note for PICMG 2.0 Revision 3.0 (October 1999,
PCI Industrial Computers Manufacturers Group).
The 6U form factor, single slot transition card supplies rear I/O connection to
support additional peripherals with simplified system cabling for use with the
compatible CompactPCI system host boards. The rear I/O access also enables the
complementary system host boards to be replaced without disconnecting cables. The
XCP2040-TRN I/O Transition Card enables the creation of high-density systems by
enabling easy access to I/O.
Note – It is the responsibility of the system designer to integrate peripheral devices
to the connectors on the backplane in a CP2040/CP2140 chassis configuration. A
designer can either connect directly to the backplane signals or use a XCP2040-TRN
I/O Transition Card.
This document contains the following sections:
■“Features” on page 2
■“Determining Part Number, Serial Number, and Revision Number” on page 9
■“Connectors” on page 10
■“PIM Card Interface” on page 28
■“Installing the Transition Card in a CompactPCI Chassis” on page 30

2XCP2040-TRN I/O Transition Card Manual for Netra CP2040/CP2140 CompactPCI Boards • October 2002
Features
The XCP2040-TRN I/O Transition Card requires a CompactPCI chassis with a
backplane that accommodates front and rear board installation. The primary
purpose of this card is to provide the connections to the CP2040/CP2140 board I/O
ports. This section lists the important features of the transition card.
These features include:
■Provides access to the I/Os available on cPCI J3, J4, and J5 connectors including
two Ethernet ports, two SCSI ports, a parallel port, a floppy header connector,
two serial ports, PS2 keyboard/mouse connectors, and two USB ports
Note – Some I/O connections are available through the rear panel; others are
available through on-board headers.
■Meets CompactPCI 6U transition card form factor specifications of 3.1 in.
(78.74mm) x 9.2 in. (233.68mm)
■Meets NEBS Level 3 compliance (see the NEBS statement in “Installing the
Transition Card in a CompactPCI Chassis” on page 30), FCC Class B, CE, UL, and
TUV
■Provides miscellaneous feature headers (I2C, backplane Reset IN/OUT, Tx/Rx)
for the System Management Controller (SMC) on the host CP2040/CP2140 board
■Supports I2C EEPROM (64 Kbits) for ID and local environmental monitoring by
the SMC for temperature
■Supports A/B cPCI connectors as described in the CompactPCI Core Specification,
Release Note for PICMG 2.0 Revision 3.0, "Connectors 2mm Type AB Connector
System" section
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Sun Microsystems Système d'E/S