CHIMNEY FIRE
• Call the re department
• Make preparations to leave the house.
• Shut off main power switch to the furnace.
• Close all combustion air openings in the furnace to reduce the re size.
• Do not remove the smoke pipe(s) until the re is completely out.
• Inspect the chimney and repair as necessary after any chimney re. Do not use
the furnace until these steps have been affected.
OIL SECTION NORMAL OPERATION
When operating with the oil burner, the furnace will cycle on call from the oil
thermostat as an oil furnace operates.
When the oil burner starts, the damper which controls the wood re will close
automatically. When using the wood section, the wood thermostat will cause the
damper motor to open the damper door on a call for heat, closing when the wood
thermostat has bee satised.
Should the temperature in the warm air plenum reach its highest allowable limit
( 230º F or 110º C ), the damper motor will close the damper door and the oil
burner will not start, the blower will continue to operate. When the temperature
returns to normal levels, the normal cycle will start.
OIL SECTION OPERATING INSTRUCTIONS
• Use No 2 furnace oil ONLY
• Do not use gasoline, crankcase oil, or any oil containing gasoline.
• Do not attempt to start the burner if excess oil has accumulated, when the
furnace is full of vapor, or if the combustion chamber is hot.
• Do not start the burner unless the blower access door in place.
• Press the burner relay reset button ONLY TWICE; if the burner fails to start,
call an Oil Burner Technician.
• If the oil burner is to be shut off for any period of time, shut the oil valve OFF
at the oil tank.
• Do not adjust or tamper with the furnace or any of the controls
• Do not burn garbage or paper in the oil section of the unit.
• Never leave paper, rags, or other combustibles around the furnace.
• Only qualied, or where required by law, a licensed technician shall set – up
this unit and adjust controls.