Stratasys ProAero Manuel utilisateur

DOC-01003 Rev. D
ProAero™
Air Extraction System
Installation and User Manual

Copyright
Page ii
© Copyright 2020 Stratasys. All rights reserved.
Copyright Statement
© Copyright 2020 Stratasys. All rights reserved.
No part of this document may be photocopied, reproduced, or translated into any human or
computer language in any form, nor stored in a database or retrieval system, without prior
permission in writing from Stratasys. This document may be printed for internal use only. All
copies shall contain a full copy of this copyright notice.
Trademark Acknowledgments
Stratasys, Stratasys logo, J55, ProAero are trademarks of Stratasys Ltd. and/or its subsidiaries
or affiliates and may be registered in certain jurisdictions. All other product names and
trademarks are the property of their respective owners.
Confidentiality
This documentation contains Stratasys proprietary information. This information is supplied
solely to assist Stratasys authorized service engineers. No part of this document may be used
for other purposes, and it may not be disclosed to other parties. The specifications on which
this document is based are subject to change without notice.
Liability Statement
Stratasys shall not be liable for errors contained herein or for incidental or consequential
damages in connection with the furnishing, performance, or use of this material. Stratasys
makes no warranty of any kind with regard to this material, including, but not limited to, the
implied warranties of merchantability and fitness for a particular purpose. It is the responsibility
of the system owner/material buyer to determine that Stratasys material is safe, lawful, and
technically suitable for the intended application as well as identify the proper disposal (or
recycling) method consistent with local environmental regulations. Except as provided in
Stratasys' standard conditions of sale, Stratasys shall not be responsible for any loss resulting
from any use of its products described herein.
Disclaimer
Customer acknowledges the contents of this document and that Stratasys parts, materials, and
supplies are subject to its standard terms and conditions, available on
http://www.stratasys.com/legal/terms-and-conditions-of-sale, which are incorporated herein by
reference.
The specifications and/or information on which this document is based are subject to change
without notice.
Technical Service
If problems arise with this system please contact Stratasys Customer Support. Contact
information is available from the Stratasys website at:
http://www.stratasys.com/customer-support/contact-customer-support.
For comments on this guide: [email protected]

Page iii
Contents
© Copyright 2020 Stratasys. All rights reserved.
Overview........................................................................................................ 1
Safety............................................................................................................. 3
Conventions used in this Guide ............................................................................................ 3
Electrical Safety .................................................................................................................... 3
Fire Safety............................................................................................................................. 4
Dangers to Eyes, Respiration, and Skin................................................................................ 4
Filter Selection ...................................................................................................................... 4
Warning and Information Labels ........................................................................................... 5
Preparation .................................................................................................... 5
Installation...................................................................................................... 7
Connecting to the Power Supply........................................................................................... 7
Connecting to the 3D Printer................................................................................................. 7
Operation ....................................................................................................... 8
Setting the Desired Airflow .................................................................................................... 8
Maintenance .................................................................................................. 9
Inspecting the System ........................................................................................................... 9
Cleaning the System ............................................................................................................. 9
Replacing the Filters ............................................................................................................. 9
Disposing of the Filters........................................................................................................ 12
System Specifications.................................................................................. 12
Dimensions ......................................................................................................................... 12
Filter Information ................................................................................................................. 13

Overview
Page 1
© Copyright 2020 Stratasys. All rights reserved.
Overview
Figure 1: Air extraction system (front)
Figure 2: Control panel
Cover
Indicators
and
controls
Cover
clip
Air
inlet
Filter change
indicator
Motor speed
adjustment

Overview
Page 2
© Copyright 2020 Stratasys. All rights reserved.
Figure 3: Air extraction system (rear)
The air outlet can be configured to suit the user’s needs. The rear outlet can be
covered using the plate screwed to the underside of the extraction system. The air
then exits through the opening under the system.
When the rear outlet is in use, cover the opening under the system with the plate.
Air
outlet
100-240V
Power
connector
Power switch
Fuse
compartment
Control cable
48 VDC Max
input

Safety Conventions used in this Guide
Page 3
© Copyright 2020 Stratasys. All rights reserved.
Safety
Conventions used in this Guide
Below are safety-related symbols used on the extraction system and referred to within this
manual.
Electrical Safety
The air extraction system has been designed to meet the safety requirements of the Essential
Health and Safety Requirements of the Machinery Directive 2006/42/EC.
Disconnect the power from the system before opening the cover.
To reduce the risk of fire, electric shock, or injury:
1. Always disconnect the system from the main power supply before servicing.
2. Use this system only as described in this manual.
3. Connect the system to a properly grounded outlet.
Warning/Danger:
Refers dangerous situations which will result in death or severe injury. Refer to this
guide before proceeding when this symbol is displayed on the system.
Caution:
Refers to a possibly harmful situation. If not avoided, damage could be caused to the
system or its environment. Refer to this guide before proceeding when this symbol is
displayed on the system.
Important:
Refers to tips and other particularly useful information. This does not indicate a
dangerous or harmful situation.

Safety Fire Safety
Page 4
© Copyright 2020 Stratasys. All rights reserved.
Fire Safety
This system is not designed to be used with processes that include any potential sources of
combustion.
It is the customer's responsibility to verify that any potential sources of combustion are
removed from the process before it reaches the system.
It is important that nozzles or other air extraction/fume capture devices and ductwork are
cleaned regularly to prevent the accumulation of potentially ignitable debris.
Dangers to Eyes, Respiration, and Skin
Dirty filters within the air extraction system contain a mixture of particulates, some of which
may be sub-micron size. Removing and replacing the filter agitates and releases some of these
particulates to the surroundings, enabling them to enter the respiratory system and eyes of the
operator. Additionally, depending on the materials used, the particulate might irritate the skin.
Filter Selection
The media within the filter in the air extraction system is capable of adsorbing a wide range of
organic compounds. However, it is the responsibility of the user to verify the media and filter
type are suitable for the particular application where the air extraction system is being used.
Caution:
Failure to clean the system and ductwork regularly may result in a fire in the system.
Warning: Hazardous Materials
When replacing filters always wear a mask, safety shoes, goggles, and gloves.
Caution:
This system must not be used with processes that use flammable materials, or with
explosive dusts and gases, without implementation of additional precautions.

Preparation Warning and Information Labels
Page 5
© Copyright 2020 Stratasys. All rights reserved.
Warning and Information Labels
The following labels appear on the air extraction system.
Preparation
Before installation, check the extraction system for damage. All packaging must be removed
before the system is connected to the power supply.
1. Move the system to the installation location and remove the outer packaging.
Labels Meaning Location
Goggles, gloves, and masks must be
worn when handling used filters. Front of system.
Do not cover any vents or holes
adjacent to the label. Bottom panel.
Electrical hazard. Removal of panels
with this label exposes electrical
components.
Bottom panel.
Warning. Turn the power to the system
off before opening the panel with this
label.
Near the cover
release clips.
If the system is used in a manner that is not specified by the manufacturer, the system
warranty is void.
Important:
Read all instructions in this manual before using this system.
• Intended use: This device is intended for indoor use only, to extract and filter
fume from a variety of 3D printers.
• Install this system in a well-ventilated area.
• If you intend to vent the air from the system directly into the room, place the
system at least 500mm (19.5 in.) from another object on the side of the air
outlet to ensure adequate airflow.

Preparation Warning and Information Labels
Page 6
© Copyright 2020 Stratasys. All rights reserved.
2. Verify that the filter is positioned correctly before replacing the cover and securing the clips.
Figure 4: Securing the cover
Caution:
Do not cover the exhaust outlets, as this restricts the airflow and causes overheating.
Cover
Pre-filter
pad
Combined
filter

Installation Connecting to the Power Supply
Page 7
© Copyright 2020 Stratasys. All rights reserved.
Installation
Connecting to the Power Supply
Follow the specifications listed in “System Specifications” (page 12) when selecting the power
supply outlet for the extraction system, and verify the power supply is suitable before
connecting the system.
The power outlet at the site should be located near the system. The power cable should be
routed so as not to create a trip hazard.
Connecting to the 3D Printer
1. Connect the control cable from the extraction system (shown in Figure 3 (page 2)) to the
AUX 24V connector in the connection panel on the back of the J55.
Figure 5: J55 exhaust vent and power connection panel
Warning: Electric Shock Hazard
The extraction system must be connected to a properly grounded outlet.
Important:
Check the integrity of the electrical power cable. If the power cable is damaged, do not
connect the extraction system to the main power supply. The power cable should only
be replaced by a Stratasys engineer, as an electrical safety test might be required after
replacement.
Exhaust duct
adapter
Control cable
connector
Autres manuels pour ProAero