StorageWorks 410 Manuel utilisateur

Getting Started
RAID Array 410 for Windows NT – Intel
Installation Guide
Order Number: EK–SMRAC-IG. C01
Digital Equipment Corporation
Maynard, Massachusetts

Third Edition, June 1996
The disclosure of this information does not grant to the user a license under any patents, pending
patents, trademarks, or copyrights or other rights of Digital Equipment Corporation, or of any third
party.
This software is proprietary to and embodies the confidential technology of Digital Equipment
Corporation.
Possession, use or copying of the software described in this publication is authorized only pursuant to
a valid written license from Digital Equipment Corporation or an authorized sublicensor.
Digital Equipment Corporation makes no representation that the use of its products in the manner
described in this publication will not infringe on existing or future patent rights, nor do the
descriptions contained in this publication imply the granting of licenses to make, use, or sell
equipment or software in accordance with the description.
© Digital Equipment Corporation 1996. All Rights Reserved Printed in U. S. A.
The following are trademarks of Digital Equipment Corporation:
DEC, RAID Array 410, StorageWorks, and the Digital Logo.
Adaptec is a registered trademark of Adaptec Co.
Intel is a registered trademark of Intel Corporation.
Microsoft and MS-DOS are registered trademarks and Windows NT is a trademark of Microsoft
Corporation

EK–SMRAC–IG. C01 iii
Contents
Revision Record ......................................................................................................v
About This Guide..................................................................................................vii
Getting Started ......................................................................................................ix
1 Unpacking and Setting Up Your RAID Array 410 Subsystem Components
1.1 Site Preparation..........................................................................................................1–1
1.2 Unpacking the RAID Array 410 (SWXRA-Yx)..........................................................1–2
1.3 Removing the RAID Array 410 from the Pallet ..........................................................1–2
1.4 Placing the RAID Array 410 Enclosure ......................................................................1–4
1.5 Installing the SWXRC-04 Controller and Write-back Cache Module..........................1–4
1.6 Installing the PC (Program) Card in the Controller .....................................................1–4
1.6.1 PC (Program) Card Handling Precautions................................................................1–5
1.6.2 Installing PC (Program) Card in Controller .............................................................1–5
1.7 Connecting the Controller to Computer ......................................................................1–6
1.8 Installing Additional Disk SBBs in the StorageWorks Enclosure................................1–6
1.9 Charging the RAID Array Controller Write-Back Cache Batteries..............................1–7
2 Host Adapter Installation
2.1 Install the Host Adapter..............................................................................................2–1
2.1.1 Preparing to Install the Host Adapter.......................................................................2–2
2.1.2 Installing the Host Adapter......................................................................................2–2
2.2 Installing the Subsystem.............................................................................................2–3
2.3 Configuration Utilities................................................................................................2–5
2.4 Loading the Adapter Driver for Use with Windows NT ..............................................2–5
2.4.1 Windows NT Not Installed on System.....................................................................2–5
2.4.2 Windows NT Previously Installed...........................................................................2–6
2.5 Installing the Device Driver (HSZDISK.SYS) ............................................................2–6
2.6 Verifying the System Recognizes the Host Adapter ....................................................2–7
3 Installing and Using the RAID Manager for Windows NT
3.1 RAID Manager for Windows NT................................................................................3–1
3.2 Overview: Installing and Using the RAID Manager for Windows NT.........................3–1
3.3 Installing the RAID Manager Software.......................................................................3–2
3.4 Setting Controller Communications............................................................................3–2
3.5 Setting the Controller Configuration...........................................................................3–3
3.6 Creating an Initial Configuration ................................................................................3–5
3.6.1 Displaying Physical/Logical View of System..........................................................3–5
3.6.2 Practice Example: Creating a Single Disk................................................................3–7
3.6.3 Practice Example: Creating a Stripeset ....................................................................3–8
3.6.4 Practice Example: Creating a Mirrorset...................................................................3–9
3.6.5 Practice Example: Adding a Spare Disk.................................................................3–10
3.6.6 Practice Example: Deleting Storagesets.................................................................3–10

Getting Started - RAID Array 410 for Windows NT – Intel
iv EK–SMRAC–IG. B01
3.7 Saving the RAID Configuration ............................................................................... 3–12
4 Completing your Configuration Setup under Windows NT
4.1 Completing Configurations under Windows NT.........................................................4–1
4.1.1 Verifying that hszdisk.sys Loaded........................................................................... 4–1
4.1.2 Completing a New RAID Array Configuration........................................................ 4–2
4.1.3 Changes to RAID Array Configuration ................................................................... 4–7
Appendix A Configuration Records – Blank Forms
Appendix B Accessing the Command Line Interpreter (CLI)
Figures
1–1 Minimum Installation Clearance Measurements ......................................................... 1–1
1–2 Unpacking the RAID Array 410................................................................................. 1–3
1–3 Installation of Ramp on Shipping Pallet .....................................................................1–3
1–4 PC (Program) Card Slot Location............................................................................... 1–6
1–5 StorageWorks SCSI Bus Port and SCSI ID Assignment............................................. 1–7
1–6 SWXSC-AA Components .......................................................................................... 1–9
2–1 Connecting SCSI Cable.............................................................................................. 2–3
2–2 SCSI Cable Connection to Controller (Single Controller)........................................... 2–4
2–3 SCSI Cable Connection to Controller (Dual Controller) ............................................. 2–4
3–1 RAID Manager Main Window (Upper Portion).......................................................... 3–2
3–2 The System ID Window............................................................................................. 3–3
3–3 Controller Configuration Window (Upper Portion)..................................................... 3–4
3–4 Physical View ............................................................................................................ 3–6
3–5 Updated Physical View .............................................................................................. 3–7
3–6 Create Window .......................................................................................................... 3–7
3–7 Updated Physical View – Disk (JBOD) Added........................................................... 3–8
3–8 Updated Physical View – Stripeset Added.................................................................. 3–9
3–9 Updated Physical View – Mirrorset Added............................................................... 3–10
3–10 Delete Window ........................................................................................................ 3–11
4–1 How The hszdisk Entry Appears When It Loads Successfully .................................... 4–1
4–2 How the hszdisk Entry Appears When It Fails To Load.............................................. 4–2
4–3 Disk Administrator Screen Display............................................................................. 4–3
4–4 Partition Pull-Down Menu.......................................................................................... 4–5
4–5 Create Primary Partition Window............................................................................... 4–5
4–6 Tools Pull-Down Choices...........................................................................................4–6
4–7 Format Menu.............................................................................................................. 4–7

EK–SMRAC–IG. C01 v
Revision Record
This Revision Record provides a concise publication history of this manual. It lists the manual
revision levels, release dates, and reasons for the revisions. It also describes how the changes
to affected pages are marked in the manual.
The following revision history lists all revisions of this publication and their effective dates.
The publication part number is included in the Revision Level column, with the last entry de-
noting the latest revision. This publication supports the StorageWorks RAID Array 410 Sub-
system.
Revision Level Date Summary of Changes
EK–SMRAC–IG. A01 February 1996 Initial Release
EK–SMRAC–IG. B01 April 1996 Updates
EK–SMRAC–IG. C01 June 1996 Updates


EK–SMRAC–IG. C01 vii
About This Guide
This section identifies the audience of this guide and describes the contents (chapter by chapter) and structure.
In addition, this section includes a list of associated documents and the conventions used in this guide.
This guide provides the following:
• Description of how to unpack and assemble the RAID Array 410 Subsystem
• How to install the Host Adapter board into your Intel-based system.
• Installing and using the RAID Array 410 Manager for Windows NT.
• Configuring the RAID Array using the RAID Array 410 Manager.
Audience
This guide is intended for administrators and system integrators of StorageWorks RAID Array
410 Subsystems. Installing the StorageWorks RAID Array 410 Subsystem requires a general
understanding of RAID concepts, Windows NT, and product installation procedures
Document Structure
This guide contains the following chapters:
Chapter 1: Unpacking and Setting Up Your RAID Array 410 Subsystem Compo-
nents
This chapter describes how to unpack and place the Office Expansion RAID Enclosure. The
chapter also describes how install the SWXRC-04 RAID controller and its PC (Program) card,
and how to recharge the write-back cache batteries.
Chapter 2: Host Adapter Installation
This chapter describes the steps required to install the host adapter in your Intel-based system.
Chapter 3: Installing and Using the RAID Array 410 Manager for Windows NT
This chapter describes how to install and use of the RAID Array 410 Manager for Windows
NT. The chapter also describes how to create your initial configuration.
Chapter 4: Completing your Configuration Setup under Windows NT
This chapter describes how to use Disk Administrator in Windows NT to complete the instal-
lation.

Getting Started - RAID Array 410 for Windows NT – Intel
EK–SMRAC–IG. B01viii
Appendix A: Configuration Record
This appendix contains blank forms that may be used to provide a record of your system con-
figuration.
Appendix B: Accessing the Command Line Interpreter (CLI)
This appendix contains procedures to access the RAID Array controller (SWXRC-04) Com-
mand Line Interpreter (CLI).
Associated Documents
In addition to this guide, the following documentation is useful to the reader:
Table 1 Associated Documents
Document Title Order Number
SWXSC-AA Office Expansion RAID Enclosure User’s Guide
EK-SMCPD-UG
SWXRC RAID Array Controller User’s Guide
EK-SMCS1-UG
RAID 410 Manager for Alpha/Intel User’s Guide
AA-QU63A-TE
Conventions
This guide uses the following documentation conventions:
Table 2 Style Conventions
Style Meaning
boldface monospace type To be input by the user
plain monospace type Screen text
italic type
For emphasis, manual titles, utilities, menus, screens, and file-
names

EK–SMRAC-IG. C01 ix
Getting Started
This section provides an overview for preparing and installing the RAID Array 410 for Windows NT in your Intel-
based system. Detailed information is contained in Chapters 1 through 5.
Thank you for purchasing a StorageWorks RAID Array 410 Subsystem. You should have re-
ceived the following:
• StorageWorks RAID Array 410 Manager for Windows NT platform kit
• StorageWorks RAID Array 410 Subsystem (SWXRA-Yx)
NOTE
• Installing the StorageWorks RAID Array 410 Subsystem
requires a technical understanding of the following:
• Intel-based Computer System
• RAID array concepts
• Windows NT
• Basic hardware installation procedures
• Or, contact your supplier or service representative for in-
stallation assistance.
The major steps for installing and setting up the StorageWorks RAID Array 410 Subsystem
include the following:
1. Performing the pre-installation steps listed below.
2. Unpacking and locating the RAID Array 410 Subsystem, installing the SWXRC-04
RAID Array controller, PC (Program) card, and write-back cache module, if they have
not been installed, and charging the write-back cache module batteries. (Chapter 1)
3. Unpacking and installing the host adapter in your computer system and connecting the
host adapter to the RAID controller. The host adapters that qualified to be used are:
• SWIA3-BB (Model AHA-2744W) for Intel-based EISA systems (Chapter 2)
• SWXA3-BC (Model AHA-2944W for Intel-based PCI systems (Chapter 2)
4. Installing the RAID Array 410 Manager for Windows NT (Chapter 3)
5. Configuring the communications port settings (Chapter 3)
6. Creating an Initial Configuration (Chapter 3)
7. Completing the Installation under Windows NT (Chapter 4)

Getting Started - RAID Array 410 for Windows NT – Intel
xEK–SMRAC-IG. C01
Installation “Checklist”
This section expands upon the preceding steps to provide a “checklist” or “roadmap” to assist
you during the installation process. Detailed procedures are provided in subsequent chapters
in this guide. Depending upon your specific configuration requirements, however, you may
not need to perform all the tasks identified:
1. Perform the pre-installation steps listed below (see this Getting Started chapter).
2. Plan your configuration: This means “mapping out” how you are going to set up your
single disks (JBODs), Stripesets, Mirrorsets, and RAIDsets in your RAID Array. (Useful
tools for this purpose are the configuration record sheets provided in Chapter 3 and the
Appendix of this guide.)
3. Unpack and locate the RAID Array 410 Subsystem. This includes:
• Positioning the RAID Array subsystem
• Installing the SWXRC-04 RAID Array controller, if it has not already been installed.
This also includes the controller’s PC (Program) card, and the write-back cache
module (Chapter 1)
• Connecting the RAID Array maintenance port to the system using the serial cable
(Chapter 1)
• Charging the write-back cache module batteries (Chapter 1)
4. Unpack and install the host adapter in your system, connect it to the RAID Array, and
verify it is recognized by your system. This guide covers the following host adapters
models:
• Host adapter for an Intel-based system (Chapter 2)
− SWIA3-BB (Model AHA-2744W) for Intel-based EISA systems
− SWXA3-BC (Model AHA-2944W for Intel-based PCI systems
5. Install the RAID Array 410 Manager for Windows NT software (Chapter 3).
6. Set the Controller communications parameters (Chapter 3).
7. Create an initial configuration (Chapter 3).
8. Record your RAID configuration (Chapter 3).
9. Complete your RAID configuration using Windows NT Disk Administrator (Chapter 4).
Pre-installation Steps:
Before starting your installation, follow these pre-installation steps:
• Back up your system files using your normal procedure.
• Verify the availability of user-supplied hardware and software.
• Inventory the contents of the StorageWorks RAID Array 410 Subsystem platform kit.
• Inventory the contents of the StorageWorks RAID Array 410 Subsystem.
Perform a System Backup
Follow normal procedures to backup your system before installing the subsystem.
Ce manuel convient aux modèles suivants
1
Table des matières
Manuels Système de disques populaires d'autres marques

Fujitsu
Fujitsu ETERNUS DX60 S2 Manuel utilisateur

Accom
Accom WSD/2XTREME Manuel utilisateur

HP
HP Compaq Presario,Presario 4400 Instructions d'utilisation

ATTO Technology
ATTO Technology Diamond Storage Array V-Class Manuel utilisateur

National Instruments
National Instruments RMX-8268 Manuel utilisateur

Overland Tandberg
Overland Tandberg SnapServer DX1 Manuel utilisateur