SSB-Electronic Zeus-1 Manuel utilisateur

Zeus-1
(ZS-1)
Software Defined
Transceiver

Table of contents
1. Foreword ……………………………………………………………………………. 3
2. Introduction ………………………………………………………………………… 4
3. Consumer Notes …………………………………………………………………. 5
3. Technical Data …………………………………………………………………….. 6
4. Su lied accessories……………………………………………………….……. 7
5. Panel descri tion ………………………………………………………………... 8
6. Precautions…………………….. …………………………………………………. 12
7. Installation…………………………. ………………………………………………. 13
8. Software installation ………………………………………………………….. 14
9. Software descri tion ………………………………………………………….. 15
Main window ……………………………………………..………….…………… 16
CW Panel ……………………………………….…………………….…………….. 28
Settings window ……………………………………………..…….……………. 31
External Control …………………………………………………….……………. 40
Predistortion Setu …………………………………………………………….. 43
TX Signal Settings ……………………….………………………………………. 45
IQ Player …………………………………………………………………………….. 49
HIQSDR ……………………………………………………………………………….. 49
10. Basic o eration …………………………………….……………………………. 50
Frequency setting ………………………………………………………………. 50
RIT, XIT and SPLIT modes …………………… …………………………….. 51
The receiving filter bandwidth …………………………………………… 53
Dis lay bandwidth …………………………………………………………….. 54
Time Machine ………………………………………………………..………….. 55
CW mode ……………………………………………………………………………. 57
SSB and AM signal transmission …………………………………………. 58
Digital modes and VAC…………………………………….………………….. 59
Audio file transmission …………………………….………………………… 60
SSB-Electronic GmbH © Page 2 of 88 V2.8.1 Content is protected by Copyright.

Table of contents
11. Software settings ………………………………….……………………………. 61
Setting the transmit signal ………………….………………………………. 61
Setting of audio devices ……………………………..………………………. 66
Transceiver frequency correction ………………………………………. 69
Setting of the CAT interface ……….………………………………………. 73
O eration by hotkeys and MIDI devices ….…………..……………… 75
TX redistortion tuning ………………………………………………………. 79
12. ZS-1 S ecifications …………………………………….……………………….. 82
SSB-Electronic GmbH © Page 3 of 88 V2.8.1 Content is protected by Copyright.

Foreword
This o eration manual will make you familiar with the o eration of the digital trans-
ceiver ZS-1.
Described are the terminal layout of the sockets, the meaning of control LEDs, the
interface, as well as o eration of the software in the version ZeusRadio v2.8.1.
We recommend to read this manual carefully before installing the software and tak-
ing the device into o eration.
SSB-Electronic GmbH © Page 4 of 88 V2.8.1 Content is protected by Copyright.

Introduction
Thank you for choosing the transceiver ZS-1. We ho e that you have fun while using
your ZS-1.
The Transceiver ZS-1 works as a „direct sam ling“ receiver, and also the transmitter
signal is created digitally by digital synthesis. The characteristics of the transceiver
will be determined in large art by the software or firmware, which is constantly be-
ing im roved.
The Transceiver ZS-1 is designed for use in radio amateur stations, together with a
PC using the o erating systems Windows 8, Windows 7, Windows Vista and
Windows XP.
SSB-Electronic GmbH © Page 5 of 88 V2.8.1 Content is protected by Copyright.

Consumer Notes
Do not o en the unit. It does not contain any arts needing maintenance. If you
need hel regarding technical matters, lease contact our team:
Packaging components (e.g. plastic film, polystyrene) can be dangerous for
c ildren. Danger of suffocation! Keep away from c ildren.
Disposal of your old appliance
This roduct is covered by the Euro ean Community directive
2002/96/EC. 2.
All electrical and electronic roducts should be dis osed of
se arately from the munici al waste stream via designated collection
facilities a ointed by the government or by the local authorities.
The correct dis osal of your old a liance will hel revent otential
negative consequences for the environment and the human health.
For more detailed information about the dis osal of your old a liance, lease
consult your city office, waste dis osal service or the sho where you urchased the
roduct.
Within Germany, the above regulations are also valid for the dis osal of batteries
and accumulators accordingly.
Declaration of Conformity
Herewith we declare that this roduct com lies with all relevant
regulations for the roduct:
EN 301 489-1 V1.8.1 (2008-04)
EN 301 489-15 V1.2.1 (2002-08)
EN 301 783-2 V1.2.1 (2010-07).
EN 60950-1:2006/A1:2010
Manufacturer : SSB-Electronic GmbH
Ostenfeldmark 21
59557 Li stadt
Contact: Email: [email protected]
Tel.: +49(0)2941 – 93385 - 0
SSB-Electronic GmbH © Page 6 of 88 V2.8.1 Content is protected by Copyright.

Tec nical Data
Sensitivity -141 dBm (MDS)
IIP3 28 dBm
Out ut ower (transmitter) max. 15W
Bandwidth u to 100 kHz
S ectrum bandwidth u to 4 MHz
PC Interface USB 2.0
Voltage 12-15 V
Current consum tion (TX) 4 A
SSB-Electronic GmbH © Page 7 of 88 V2.8.1 Content is protected by Copyright.

Supplied accessories
The Transceiver ZS-1 is su lied with the following accessories:
1. USB 2.0 cable 1 c.
2. DC cable with connector 1 c.
3. Ferrite core 1 c.
4. CD with software 1 c.
SSB-Electronic GmbH © Page 8 of 88 V2.8.1 Content is protected by Copyright.

Panel description
Front panel
1 POWER
LED Indicator shows the existence of the su ly voltage.
Note: The indicator does not light up until the transceiver is connected to the PC.
2 ACTIVE
LED Indicator shows the o eration mode of the transceiver.
When the ZeusRadio is not used or the USB cable is not connected, the LED
indicator will go out and the transceiver is in the stand-by mode.
3 TX
LED Indicator for transmission mode.
SSB-Electronic GmbH © Page 9 of 88 V2.8.1 Content is protected by Copyright.
123

Panel description
Rear panel
1 GND
Grounding terminal. Connect this terminal to a ground to revent electrical
shocks and ensure o timum erformance.
2 12-15 VDC
Jack for the su ly voltage. The inner contact of the connector has to be
connected to the ositive terminal of the ower su ly, the outer contact with
negative one.
WRONG POLARITY (REVERSED) WILL DAMAGE THE TRANSCEIVER.
BEFORE CONNECTING A POWER SUPPLY TO THE TRANSCEIVER, lease check that
the both devices (transceiver and ower su ly) are grounded. A missing or
im ro er ground connection can be the reason of electrical shock to the o erator
or can im air ro er o eration of the transceiver.
Please be sure that no electrical contact exists between the outer contact of the
connector (negative terminal) and the transceiver chassis. This could lead to
increased RFI.
SSB-Electronic GmbH © Page 10 of 88 V2.8.1 Content is protected by Copyright.
“+”
“-”
4
6 7
8
5
1 2 3 9
Table des matières